AD-900 MN3008 Version
Build Document
D-Time
Repeat
D-Level
Analog Delay
AD-900
Effect In / Out
Tails On/Off

Advertisement

loading
Need help?

Need help?

Do you have a question about the AD-900 MN3008 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Analog Devices AD-900 MN3008

  • Page 1 AD-900 MN3008 Version Build Document D-Time Repeat D-Level Analog Delay AD-900 Effect In / Out Tails On/Off...
  • Page 3 AD-900 MN3008 Version Overlay...
  • Page 4 AD‐900 MN3008 BOM QUANTITY    Qty Value Device Parts 1 47pf 2 100pf C7, C37 1 330pf 3 470pf C4, C34, C42 1 820pf 1 .0039uf film 1 .01uf “ 1 .027uf “ 2 .033uf “ C3, C41 1 .039uf “ 1 .047uf “...
  • Page 5 AD‐900 MN3008 BOM QUANTITY    1 2SA1015GR 2 2SC1815GR Q6, Q7 4 2SC1815BL Q1, Q2, Q3, Q4 1 1N4001 2 1N4148 D2, D3 1 1N4738A 8.2V zener 1 LM78L12ACZ 4 MN3008 IC3, IC4, IC6, IC7 1 MN3101 IC5, IC8 1 RC4558D 1 SA571N 5 CHECK POINTS CP1, CP2, CP3, CP4, CP6 2 ¼”...
  • Page 6 AD‐900 MN3008 BOM designations    C1 .047uf film R14 10K TR11 20K (RM-065) C2 1µf NP elect R15 220K C3 .033uf film R16 5.1K P1 10KC C4 470p ceramic R17 5.1K P2 20KB C5 1uf elect R18 130K P3 10KA C6 .22uf elect R19 130K C7 100pf ceramic...
  • Page 7 AD-900 MN3008 Version PC Board Set printer to "No Scaling" or 100%...
  • Page 8 AD-900 OFFBOARD WIRING REPEAT BLEND D-TIME 3 2 1 3 2 1 3 2 1 22 15 20 21 4 TAILS ON/OFF EFFECT IN/OUT...
  • Page 9 AD‐900 Alignment Procedures (MN3008 version)    1. Setting before alignment    1) De‐solder and remove one lead of R58 (10K) to cut the dry signal line.    2) Turn TR6 (level) trimmer CW. Set all other trimmers to 50%.  2. Power Supply    1) Connect DC power supply to AD‐900 DC input jack.  3. Clock alignment       Setting: Insert shorted ¼” plug into Input jack and turn controls as follows.                        D‐Time CW,      Repeat CCW,    D‐Level  CW      1) Connect the probe of frequency counter to CP6. (clock line)      2) Turn TR1 to align clock to 7KHz ±200Hz.      3) Turn D‐Time control CCW. Check if the frequency counter indicates 110 to                                            .       140KHz.  4. BBD Balance alignment             Setting: Insert shorted ¼” plug into Input jack and turn controls as follows.                        D‐Time CW,      Repeat CCW,    D‐Level  CW        1) Connect the probe of oscilloscope to CP1.             Set the oscilloscope to get the waveform as shown in fig. 1‐a.        2) Turn TR3 to get the waveform as shown in fig. 1‐b.        3) Connect the probe of oscilloscope to CP2.        4) Turn TR5 to get the waveform as shown in fig. 1‐b.        5) Connect the probe of oscilloscope to CP3.        6) Turn TR8 to get the waveform as shown in fig. 1‐b.         7) Connect the probe of oscilloscope to CP4.         8) Turn TR10 to get the waveform as shown in fig. 1‐b. ...
  • Page 10 AD‐900 Alignment Procedures (MN3008 version)         4. BBD Bias alignment                   Setting: Input 400Hz/0dBu sine wave (0dBu = .78V RMS) into AD‐900 input  generator.       with audio generator and turn controls as follows.                        D‐Time CCW,      Repeat CCW,    D‐Level  CW           1) Connect the probe of oscilloscope to CP1.           2) Turn TR2 and align sine wave to be symmetrical at top and bottom               Turn D‐Time control CW, check if sine wave is symmetrical.               Fig.2‐a & 2‐b depict sine wave out of symmetry.               Fig. 2‐c depicts sine wave symmetrical (D‐Time CCW)               Fig. 2‐d depicts sine wave symmetrical (D‐Time CW)            3) Connect the probe of oscilloscope to CP2.            4) Turn TR4 and perform the same alignment as mentioned above.            5)  Connect the probe of oscilloscope to CP3.            6) Turn TR7 and perform the same alignment as mentioned above.            7) Connect the probe of oscilloscope to CP4.              8) Turn TR9 and perform the same alignment as mentioned above.                     ...
  • Page 11 AD‐900 Alignment Procedures (MN3008 version)              6. Level alignment            Setting: Input 400Hz/‐20dBu sine wave (‐20dBu = .078V RMS) into AD‐900 input  genera  with audio generator and turn controls as follows.                           D‐Time CW,      Repeat CCW,    D‐Level  CW            1) Connect level meter to output jack.            2) Turn TR6 and align output level to ‐20dBu.            3) Alternate: Turn TR6 and align output level for .078V RMS.  7. Connection of dry signal line                        Solder R58 (10K) which had been removed in 1. 1) and connect dry signal.  8. Sound check                     1) Repeat alignment                  Setting:  D‐Time CW,      Repeat 3:00,    D‐Level  CW                  Input guitar signal and align TR11. Repeats should last 10 times before  becominbecoming inaudible on the 11  time. Check if self‐ oscillates when turning  turning  Repeat control fully CW.             2) Check the function of each control.                             ...
  • Page 12 AD‐900 Alignment Procedures (MN3008 version)                                      Fig. 1a                                                    Fig. 1b                                     Fig. 2a                                                     Fig. 2b                                       Fig. 2c                                                    Fig. 2d ...
  • Page 13: Analog Delay

    AD-900 MN3008 Version Drilling Template D-Time Repeat D-Level Analog Delay AD-900 Effect In / Out Tails On/Off...