Content 1.General..........................1 2.Specification.........................2 3.Function..........................3 4.How to install........................3 4.1 Notes of installation......................3 4.2 Installation........................4 4.3 Printed instruction on the box..................10 5.1 Turn on Controller......................11 5.2 How to register to GG-002WIFI/3G system main controller........12 5.3 How to establish wireless communication mesh network........... 12 5.4 How to turn off controller.....................14 5.5 Controller sleep......................
1.General FMP-Solar-MB controller controls pump and master valve, measures flow rate, and water pressure. Compatible with GG-002 WiFi / 3G wireless control system. Solar powered with water proof shell design, good for outdoor application. 2.Specification Solar Panel: 17.4V DC /220mA/3.8W (Support Extra panel) Back battery: 10*1.2V/ 2.3AH AA NiMH Solar charging time: About 10 hours under standard sunlight Idle power:1mA...
Valve specification: 1,Voltage:6-12VDC Pulse 2, Latching valve 3,Extension valve cable up to 20 meters Pump control output:Open-(12VDC) Close-(0VDC) Controller box size:Long:28cm Wide:17.5cm High:28.2cm Controller box protective grade: IP56 Extension cable for pump up to 50 meters. 3.Function 1,ASA weather proof shell design, water proof, for outdoor application 2,Solar powered, wireless, no need of power or communication lines in the field.
4.How to install Please read manual before installation. We have how to install video online. 4.1 Notes of installation 1,Make sure solar panel is face maximum sun. If there is not enough sun, add extra solar panel. 2 , For application of controlling pump and master valve, must install protective pressure sensor or pressure switch.
Page 8
4.2.2 How to install pressure sensor Note: Because that the threaded end of pressure sensor is very small, suggest using three way adaptor for small pipe, and drill hole to install for big pipe according to related specification. When water pressure is out of setup range, the controller will protectively shut off the pump or master valve.
Page 9
4.2.3 Valve connection For master valve, choose one of them as protective devices, pressure switch, pressure sensor, or flow meter. To mechanical pressure switch, must do tiny adjusting when water go through pipe, adjusting the screw until no alarms at normal situation. (Open water proof cap to do adjusting.
Page 10
There are only total 5 wireless flow meter controllers for one GG-002 WIFI/3G system. 4.2.4 How to install battery Remark: 1). Battery standard: Rechargeable Ni-MH AA battery 1.2v*10 2). Please pay attention to (+/-) sign 3). Suggest to use more than 2300mAh rechargeable battery. Installation steps: 1).
Batteries 4). Put the battery box back, cover up and srew tight. 4.3 Printed instruction on the box When connecting external devices, following printed instructions either on the coneecting cabel ANC supplied, or on the controller as following: Warming: Make sure tight waterproof connectors right. All unused waterproof connectors need to keep inside the metal box to avoid the water damage.
5.How to operate 1-Metal box 2- battery box 3- lines 4-Pump manually on/off button 5-Pump manually on/off button 6-Decimal input 7-digit keys 8-Information window switch 9- LCD 10- antenna cable 5.1 Turn on Controller Push the red power key at right low end of the controller will turn on and lock up the on position.
If there is no sun to charge battery for some time, the battery voltage will reach low point, then controller will protectively shut down self , and automatically wake up after the battery is been recharged again. 5.2 How to register to GG-002WIFI/3G system main controller FMP-Solar-MB needs to register one by one following parts if you choose to sue them: 1.
Page 14
communication route yet. During search, the keys are been locked up. LCD show as following: After successfully established route, the FMP-Solar-MB field controller will send the route information to main controller. If done, main controller will show “ ” icon on related LCD screen, route show as “√”.
communicate with field controllers. After the field controllers found the route, will keep send the route information to the main controller every one minute, if tried three times without success, will looking for another route. Note 3: If the established route no more working, the controller will automatically search new route after one hour try.
5.6 Field manual open/close 5.6.1 Field manual open/close During working status, push “valve” key , LCD show valve status as “Manual on” , the controller will open the master valve, and send current status to main controller. Push “valve” key again, LCD show status as “Manual off” ,which will manually turn off valve.
stabilizing flow rate and water pressure, then setup right delay time for alarm. And setup right flow and pressure range. 5.7 Explanation of LCD information 5.7.1 Main working LCD display 1,Pump status:Above LCD display of “Auto off”, which means current status is auto off. Pump has 6 status, Auto off、Auto on、Manual off、Manual on、Remote on、Remote off.
Page 18
function is been enabled. If this function is been enabled, there is “ ” icon. First reminder show as “ ”, second reminder show as “ ” icon. After valve been turned off, flow rate reach to 0, this flow meter controller will automatically finish this cycle of fertilizing reminder.
Page 19
During communication time between FMP-Solar-MB and main controller, LCD shows as above. Then all the keys been locked up until communication finished. 5.7.4 Detail information windows During normal work status, push【1】【2】【3】【4】digital keys switch for different work information. Keep push【Enter】key,switch and cycle information window. Push key【1】,show flow meter information as following: Flow meter registration #:Here show as 1,which means registered as #1 flow meter in this system.
Page 20
Master valve registration #:Here #1 means this master valve is been registered as #1 master valve in this system. (If not registered, will show “Not registered”). 2. Master Valve status: The status are: Auto off、 Auto on、 Manual off、 Manual on、 Remote on、Remote off。...
6.How to setup This controller control one flow meter, one pressure sensor, one pump and one master valve. Each has individual setup menu. Push【Menu】 into main menu, push 【Menu】 again to browse. Push 【Enter】 into the setup. Push 【Exit】 key to exit or exit without operation after 1 minute.
Page 22
6.1.1 Register/Remove flow meter Browse into Reg(registration)/remove flow meter menu, there is current registration information as following. If not registered, will show “not registered”. Push【Menu】key to choose register or remove, push【Enter】key to execute. Registration: Any registration needs to do with main controller simultaneously. Both need to be at registering stage.
Page 23
will overlap old ones. How to remove: There are two kinds of remove operation, one is remove registration information from main controller and field controller simultaneously, and another is remove from field controller only, and remove from main controller later on. Remove from field controller only:...
Page 24
Remove simultaneously: Remove registration information from main controller and FMP controller simultaneously. Let FMP controller get ready for remove same as above. When FMP controller start to search main controller, let main controller also into remove menu and get ready. Then the registration information will be removed from both simultaneously.
Page 25
following; Push 【Menu】 key to choose between MIN and MAX,highlighted one is the one been chosen. Input digits, push 【Exit】key to delete one digit, less than 5 digits, push【Enter】 key to confirm. After done with edit MIN-MAX value, push【Enter】key to save and back to previous menu.
6.2 Pressure meter setup Browse into “Set up pressure meter” menu: There are “Reg/remover pressure meter” and “set up pressure range” two choices as following: 6.2.1 Reg/remove pressure meter Reference 6.1.1 flow meter register and remove. 6.2.2 Setup pressure range (0 - 1Mpa) Reference 6.1.3 flow meter flow rate range setup.
Page 27
6.3.1 Register and remove pump Reference 6.1.1 flow meter registration and remove. 6.3.2 Set up pump protection sensor Browse into “Set up pump” menu, there are “Disabled”, “flow meter”, “Pressure meter”, “Liquid level switch” 4 choices as following: In the Sensor option to choose, if choose 0, which means no protection for the pump. If choose like above, 1 and 2, which means choose flow meter and pressure sensor as protective sensors.
alarm, adjusting the setup. ( Level sensor protection: The level sensor will first check if the water level reach high level before open the pump to prevent open pump without much water. During normal operation, if the sensor detected low water level, will protectively turn off the pump.
Page 29
6.4.1 Register/Remove master valve Reference 6.1.1 flow meter registration and remove. 6.4.2 How to setup detection devices Browse into “Sensor options” menu, there are Disabled-Flow meter-Pressure meter-Pressure switch 4 choices, choose 1, or up to 3 items as shown at following: If key in 0...
After open valve, after delay time, if current pressure reading is less than setup MIN,open failure otherwise normal. After close valve, after delay time, if pressure reading is bigger than setup MIN, close failure otherwise normal. ( Pressure switch protection Protection function same as pressure meter.
Page 31
Preparing one field controller with the new software you want. You can do this by buying a new one from ANC Technology, or send one old version field controller to ANC Technology for update at a fee. This new version field controller would be used to update all other existing wireless field controllers.
Page 32
Figure 2.3 Figure 2.4 4. The upgrading interface will show the upgrading progress. The upgrade procedure takes a few minutes. Make sure the distance of two units are at effective communication distance of 2m≤X≤500m, to grantee good wireless communication. 5. After successful upgrade, LCD will show as Figure 2.5 Figure 2.5 8.
Page 33
Shanghai ANC Technology Limited Warranty card Dear Customer: Thank you very much for choosing ANC products. 1. This product has FCC verification. 2. Warranty period is one year. Beginning on day of receipt. 3. Please keep your receipt and this warranty card.