(RESET)
In case of a RESET, all codes registered with the
alarm module are deleted.
1. Press button 0 and button 1 simultaneously
until both LEDs blink. If you want to cancel the
process, briefly press the button 0.
2. Keep the buttons 0 and 1 depressed
simultaneously once again until both buttons
are lit. All codes were deleted and the alarm
function is no longer active.
> 1,6 s
> 1,6 s
3 s

General Information

Disposal
Waste electrical products should not be
disposed of with household waste!
Dispose of the waste product via a collec-
tion point for electronic scrap or via your
specialist dealer.
Put the packaging material into the
recycling bins for cardboard, paper and
plastics.
Warranty
We will remedy defects on the device based on
material or production errors within the statutory
warranty period or exchange the device.
Any unauthorized tampering with, or modifica-
tions to, the product shall render this warranty null
and void.
Conformity
The product fulfils the essential require-
ments of the R&TTE directive
1999/5/EG.
For application in: EU/CH/FL/IS/N
The Declaration of Conformity can be found on
the internet at: www.eldat.de.
Customer Service
If the device does not work properly despite
proper handing or in case of damage, please
contact your retailer or the following adress:
RTS Automation Vertriebsges. Ltd.
ELDAT GmbH
Warschauer Str. 7
Im Gewerbepark 14
DE-03042 Cottbus
15711 Zeesen
Phon: +49 355 280 9311
Germany
Mail: huk@rts-automation-limited.de
Phone:
+ 49 (0) 33 75 / 90 37-0
Internet: www.rts-automation-limited.de
Fax:
+ 49 (0) 33 75 / 90 37-90
Internet: www.eldat.de
E-Mail:
info@eldat.de
Plug-In Radio Alarm Annunciator RTRP02
GB
Models
Scope of Delivery
Alarm annunciator RTRP02, Operating
instruction
Wall outlet

Safety Advice

We do not accept any liability for personal
injury or damage to property caused by
Loudspeaker
incorrect handling or non-observance of the
safety instructions!
Keep the Alarm annunciator away from
children!
Attention!
Button1/LED1
voltage and the maximum contact load of the
ON
wall outlet (16 A, 230 V AC / 50 Hz)!
Observe the valid laws and regulations as well
as the manufacturer's instructions
devices to be operated.
Battery control
Have malfunctioning devices checked by the
notice
manufacturers!
Button 0/LED 0
Do not open the appliance's casing!
OFF
Do not make any unauthorized alterations or
modifications to the device!
Plug systems

Concept of Operations

Function/Chapter
D/A/NL/S/N
GB
Memorizing a
Window handle
contact RTS26
Memorizing an
acknowledgement
F/B/PL
CH
transmitter
RTRP02-5001E
-01
868.30 MHz
D
Art.-No. G65 031 00
Art.-No. G65 031 01
RTRP02-5001E
-02
868.30 MHz
GB
Switch on
Art.-No. G65 031 02
RTRP02-5001E
-04
868.30 MHz
F/B
alarm function
Art.-No. G65 031 03
RTRP02-5001E
-05
868.30 MHz
CH
Switch off
alarm function

Technical Details

Acknowledge the
alarm
Frequency:
868.30 MHz
Modulation:
FSK
Channel:
1x receive 2x transmit
/
Range:
Outdoor:
approx.150 m
(Transmission
Indoor:
approx.
30 m
code A1 (ON)
Operating voltage: 230 V AC / 50 Hz
transfer)
Current consumption
- real power:
max. 0.6 W
- apparent power: max. 1.8 VA
Protective class
:
II
(
Transmission
Degree
protection:IP 20
of
code B2 (DOWN)
Operating
transfer)
temperature:
-20°C to +60°C
Max. relative air
Reset to Default
humidity
:
60%
Settings (RESET)
Mains output
:
Power plug
(
non switchable
)
Max. contact load
:
16 A / 230 V AC
Dimensions
:
122 x 50 x 38.3 mm
(HxWxD)
Undervoltage
Weight:
approx. 190 g
message window
handle contact
SPL:
85 dB / distance 30 cm
Intended Use
The alarm indicator RTRP02 may only be used in
dry indoor rooms as acoustic signalling device for
alarm messages and messages concerning the
battery status of the window handle contact
RTS26 (evaluation of undervoltage diagram).
The outlet can only be used for mains voltage
Carefully read through these
consumers (16 A, 230 V AC, 50 Hz).
instructions before using the
The manufacturer will not be liable for damage
device.
caused by improper or inappropriate use

Function

The alarm indicator RTRP02 is a wireless
receiver that reports manipulations to the window
handle by emitting an acoustic signal in
Observe the admissible supply
connection with an activated wireless window
handle contact RTS26.
Altogether 32 window handle contacts can be
monitored by the alarm indicator.
for the
It is also possible to evaluate an undervoltage
telegram indicating the low battery status of a
window handle contact.
The low battery status is signalled with a blinking
battery status display and can be deactivated by
pressing the button 1 or 0 on the alarm indicator.
This function is also available when the alarm
indicator is deactivated.
Operation
LED-view RTRP02
Result
[press the button]
1. button 0 + button 1 >1,6 s
LED 0 + LED 1 flashes
after 20 s operation mode
button 0
break
2.
button
RTS26
LED 1 lights up 3 s
afterwards operation mode
1. button 0 + button 1 >1,6 s
LED 0 + LED 1 flash
after 20 s operation mode
button 0
break
2. button 1 >1,6 s
LED 1 flashes
after 20 s operation mode
button 0
break
3.
LED 1 lights up 3 s
afterwards operation mode
button acknowledgement trans.
button 1 >1,6 s
LED 0 + LED 1 light up
Alarm annunciator activates
button 0 >1,6 s
LED 0 + LED 1 out
Alarm annunciator deactivates
button 0 oder button 1
Further alarm messages are
possible after 5 minutes.
or
button acknowledgement transm.
1. button 0 + button 1 >1,6 s
LED 0 + LED 1 flash
after 20 s operation mode
button 0
break
2. button 1 >1,6 s
LED 1 flashes
after 20 s operation mode
button 0
break
3. button 1
LED 1 lights up 3 s
Send code A1 is sent for 3 s,
afterwards operation mode
1. button 0 + button 1 >1,6 s
LED 0 + LED 1 flash
after 20 s operation mode
button 0
break
2. button 0 >1,6 s
LED 0 flashes
after 20 s operation mode
3. button 0
LED 0 flashes 3 s
Send code B2 is sent for 3 s,
afterwards operation mode
1. button 0 + button 1 >1,6 s
LED 0 + LED 1 flash
after 20 s operation mode
button 0
break
LED
LED
2. button 0 + button 1 >1,6 s
0
+
1 light up 3 s
dann operation mode
acknowledge with
battery control notice
change the battery of the
button 0 oder button 1
flashes
window handle contact
.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Easywave RTRP02 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for RTS Easywave RTRP02

  • Page 1 Indoor: approx. 30 m code A1 (ON) button 0 break RTS Automation Vertriebsges. Ltd. Operating voltage: 230 V AC / 50 Hz transfer) ELDAT GmbH 3. button 1 LED 1 lights up 3 s Send code A1 is sent for 3 s, Warschauer Str.
  • Page 2 If the window handle contact detects a Memorizing the code of a window Memorizing the code of an Aktivate/deactivate the Switch on lighting Close a shutter movement of the window handle, a radio handle contact RTS26 acknowledgement transmitter alarm function This function serves to transmit the Easywave This function serves to transmit the Easywave message is sent to the alarm indicator and an...

This manual is also suitable for:

G65 031 00G65 031 01G65 031 02G65 031 03

Table of Contents