Page 1
M A N U A L OVERVIEW Our SL-720 floor scale weighing kit has everything you need to build your own weighing scale. It enables you to use any platform of your choice (platform not included with the kit). This weighing kit is mostly used for floor scale, livestock scale applications or to turn any object, platform into a...
Page 2
SL-720 INSTALLATION MANUAL - WEIGHING KIT Our SL-720 weighing kit comes with all the accessories you need for installation. ACCESSORIES • x 4 load cells with 10' cable • x 4 load spacers ( installed in-between the load cell & the mounting block ) •...
Page 3
SL-720 INSTALLATION MANUAL - WEIGHING KIT OVERALL INSTALLATION FOR WOODEN PLATFORMS Step 1: Make sure the wooden platform you've built – or are in the process of building – can withstand the maximum weight you'll put on it. Step 2: Turn the platform upside down.
Page 4
SL-720 INSTALLATION MANUAL - WEIGHING KIT IF YOU'RE USING A STEEL PLATFORM: You will need to weld each mounting block to the corner of the platform. Only weld on the outside of the mounting block & ensure that all blocks are positioned in the same way, with the feet of the load cell located in the corner of the platform (not facing inside the platform).
Page 5
SL-720 INSTALLATION MANUAL - WEIGHING KIT Please refer to the diagram below for the indicator cable & load cell wiring: CAPACITY & ACCURACY CHOICES: - 1000 lb Capacity x .2 lb Accuracy - 2500 lb Capacity x .5 lb Accuracy...
Page 6
SL-720 INSTALLATION MANUAL - WEIGHING KIT CALIBRATION PROCEDURE 1. Turn on the scale by holding ON/OFF for 2 seconds. 2 Press HOLD and PRINT together to access the setup menu. C01 . 3. If done correctly, the display should now show [C I #].
Page 7
SL-720 INSTALLATION MANUAL - WEIGHING KIT 18. Press ZERO to change the value to 1. 19. Press PRINT The display will count down from 10-1 while the scale is calibrating zero. When the display shows 0 the zero calibration is complete.
Page 8
SL-720 INSTALLATION MANUAL - WEIGHING KIT TROUBLESHOOTING Error Codes Error Reason Solution 1. Reduce the weight 1. Overload 2. Check load cell connection uuuuuu 2. Wrong connection with load cell 3. Inspect load cell; Check the input/output 3. Load cell has quality problem 4.
Need help?
Do you have a question about the SL-720 and is the answer not in the manual?
Questions and answers