OVERVIEW
![Gewiss - CHORUS GW 10 904 - Overview Overview]()
- Front LED
- Sensitive touch area
- Programming push-buttons
TURN ON/OFF
To activate or deactivate (ON / OFF) the load, quickly touch the surface (sensitive touch area)
of the switch. All of the operations for turning the load on or off are also possible using the GW10906-GW12906-GW14906 control duplicator or using normally open push-buttons.
![Gewiss - CHORUS GW 10 904 - Turn On/Off Turn On/Off]()
LOAD TYPE
![]()
NOTE: for any load types not indicated in fig. A, use a support relay.
WIRING
![Gewiss - CHORUS GW 10 904 - Wiring Wiring]()
PROGRAMMING
|
Parameter
|
ON
|
OFF
|
1st
|
localisation (*)
|
enabled
|
disabled
|
2nd
|
acoustic signal
|
enabled
|
disabled
|
3rd
|
output contact functionality
|
latching
|
momentary
|
(*) Luminous double intensity blue front LED:
- low = localisation
- high = control received
To access the Parameter Modification Procedure
Press the programming push-button (side position) for at least 4 seconds (use the tip of a pen for example). ATTENTION: when the Procedure is activated, all Parameters are automatically set to ON.
1st parameter LOCALISATION
- Access to setting the 1st parameter is indicated by a single signal, acoustic (1 beep) and luminous (1 flash) that is repeated cyclically every 2 seconds.
- To confirm ON "Localisation enabled" (LED always on with low intensity), press the push-button on the side. It then automatically continues with the next parameter.
- To switch to OFF "Localisation disabled", press the front touch control (quick touch): the front LED will turn on for 1 second.
- After the front LED turns off, it then automatically continues with the next parameter.
- With "Localisation disabled", the LED turns on only to indicate a received control or that the "Inhibition" function is activated.
2nd parameter ACOUSTIC SIGNAL
- Access to setting the 2nd parameter is indicated by a dual signal, acoustic (2 beeps) and luminous (2 flashes) that is repeated cyclically every 3 seconds.
- To confirm ON "Acoustic signalling enabled" (the buzzer signals every received control), press the push-button on the side. It then automatically continues with the next parameter.
- To switch to OFF "Acoustic signalling disabled", press the front touch control (quick touch), the front LED turns on for 1 second.
After the front LED turns off, it then automatically continues with the next parameter.
- With "Acoustic signalling disabled" the buzzer only signals entering/exiting the "Parameter setting" procedure and that the "Inhibition" function is activated.
Note: In the case of a control from the duplicators, the buzzer will not emit an acoustic signal.
- Access to setting the 3rd parameter is indicated by a triple signal, acoustic (3 beeps) and luminous (3 flashes) that is repeated cyclically every 3 seconds.
- To confirm ON "latching" (stepping relay function), press the push-button on the side. You will automatically exit the parameter modification procedure.
- To switch to OFF "momentary", press the front touch control (quick touch): the front LED will turn on for 1 second.
- You will automatically exit the parameter modification procedure after the front LED turns off.
Output
If no selection is made for 30 seconds, you will automatically exit the parameter modification procedure (in this case, the parameters that were just set will be saved). Exiting the procedure due to time-out is signalled by a long "beep".
Inhibition function
To clean the front plate without continuously activating the output contact, the touch device can be temporarily inhibited by pressing it for at least 10 seconds in the sensitive area. An acoustic signal (5 beeps) will indicate that the inhibition status has been activated. The inhibition status lasts 20 seconds, during which the front LED will flash. The exit from the inhibition status, and return to normal operation, is indicated by an acoustic signal (5 beeps).
Contact details according to the relevant European Directives and Regulations:
GEWISS S.p. A, Via A.Volta, 1 IT-24069 Cenate Sotto (BG) Italy tel: +39 035 946 111 E-mail: qualitymarks@gewiss.com
![]()
![]()