Parts: K1 - K3
New
Ref.
Description
K1
K1
(1x) Switch Box
K1.1 Red Wire
K2
K2
(2x) Connector, 10-12 AWG
K3
K3
(1x) Connector, 14-16 AWG
NI
A
RV Power Source
A.1
Power Source Red Wire
NI
B
Pump
B.1
Pump Black Wire
B.2
Pump Blue Wire
B.3
Pump Black Wire - Negative (Long Wire)
NI
C
Fuse Holder / 35AMP Fuse
NI
NOT INCLUDED - Reference only.
Tools Needed:
■ Wire Cutter/Stripper
■ Wire Crimper
■ Heating Tool
Thetford Corporation recommends that only
AVIS
NOTICE
AVISO
ATTENTION
ATENCIÓN
CAUTION
DANGER
DANGER
!
!
!
!
!
a trained and qualified technician service this
ATTENTION
ATTENTION
ATTENTION
ATTENTION
product and plumbing and electrical work be
performed by a licensed tradesperson. Local
permit and code compliance is required.
Thetford Corporation accepts no responsibil-
ity or liability for damage to equipment, injury,
or death that may result from the system's
improper installation, service, or operation.
Be sure power has been disconnected before
you continue.
The switch box is intended for indoor use only
and must be protected against water.
Questions?/Des questions?/¿Preguntas? 1-800-543-1219
P.O. Box 1285
Ann Arbor, MI 48106
www.thetford.com
Switch Box Kit
K2
K1
K1
Part No.
N° de pièce
Pieza n.°
+
A
A.1
PREPARE
■ Flush all debris from holding tanks.
■ Close all dump valves.
REMOVE PART
USE OLD PARTS:
A
1.
Locate
; disconnect positive red wire
2.
Leave ample wire length by cutting
K1;
close to
discard (old)
REPLACE PART
USE NEW PARTS:
Protect wires from foreign objects and water
AVIS
NOTICE
AVISO
ATTENTION
ATENCIÓN
DANGER
CAUTION
!
!
!
!
with wire sheath (not provided).
ATTENTION
ATTENTION
ATTENTION
K1
1.
Secure
in the RV compartment.
K1
2.
To connect
:
K2
• Use
to connet
K3
• Use
to connect
3.
To seal heat shrink connectors, heat the connectors after the
wires are connected. Connect additional wiring if required.
A.1
A.
4.
Reconnect
to
K1
5.
Power up
; verify voltage at motor is 12V.
Improper installation may damage to motor or
AVISO
AVIS
NOTICE
CAUTION
!
decrease motor efficiency.
1
Made in the U.S.A.
Fabriqué aux É.-U.
Hecho en EE. UU
B.3
C
B.2
BAT
AUX
K1
Fuse
B.1
K1.1
A.1
.
K1.1
B.1
and
K1
.
B.1
K1.1
and
.
B.2
.
Form/Formulaire n°/Formulario n.° 97641 Rev. A 04.25.17
97603
B
B.2
and