Keysight E8718A Radar Target Simulator User Guide...
Page 2
FAR 27.401 or DFAR could result in personal injury or death. 227.7103-5 (c), as applicable in any Do not proceed beyond a WARNING technical data. notice until the indicated conditions are fully understood and met. Keysight E8718A Radar Target Simulator User Guide...
General information The E8718A Radar Target Simulator (RTS) is provided with a protective earth terminal. The protective features of the E8718A may be impaired if it is used in a manner not specified in the operating instructions. DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE. Do not operate the WARNING E8718A in the presence of flammable gases or flames.
Before applying power Verify that the E8718A is set to match the available line voltage and ensure all safety precautions are taken. Take note of the external markings on the E8718A as described in “Safety Symbols” on page 6 and “Regulatory Markings”...
In order to avoid eye damage, do not stare at the laser. WARNING The E8718A is equipped with laser module for device under test alignment purpose. Do not stare at the laser while operating it. Switch off the laser when not in use.
Persuant to Laser Notice disconnect the power cord or have a No.50 June 24 2007. qualified technician install an external switch. Keysight E8718A Radar Target Simulator User Guide...
This symbol is a South Korean Class A EMC Declaration. This is a Class A instrument suitable for professional use and in electromagnetic environment outside of the home. Keysight E8718A Radar Target Simulator User Guide...
To return this unwanted instrument, contact your nearest Keysight Service Center, or visit http://about.keysight.com/en/companyinfo/environment/takeback.shtml for more information. Sales and Technical Support To contact Keysight for sales and technical support, refer to the support links on the following Keysight websites: – www.keysight.com/find/rts (product-specific information and support, software and documentation updates) –...
Page 11
........49 Figure 4-3 E8718A Remote Head Front View - Location of Laser Aperture .
Page 12
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK. Keysight E8718A Radar Target Simulator User Guide...
Page 13
PC location of the installation path and installed files Table 3-2 Configuration Limit ......38 Keysight E8718A Radar Target Simulator User Guide...
Page 14
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK. Keysight E8718A Radar Target Simulator User Guide...
User Guide Getting Started Electrostatic Discharge (ESD) Precaution Inspect the Instrument for Damage Return the Instrument for Service Verify the Shipment Contents This chapter describes the ESD precaution along with the steps to inspect and verify the contents of the E8718A.
Getting Started Electrostatic Discharge (ESD) Precaution The E8718A is shipped in materials which prevent damage from static. The CAUTION instrument should only be removed from the packaging in an anti-static area after ensuring that correct anti-static precautions are taken. Store all instrument in anti-static envelopes when not in use.
Getting Started Figure 1-1 Static-safe work station example The following ESD symbol indicates areas where ESD caution must be exercised to prevent test disruption and damage to the E8718A. Keysight E8718A Radar Target Simulator User Guide...
1 Ω of isolation from ground. These techniques for a static-safe work station should not be used when WARNING working on circuitry with a voltage potential greater than 500 V. Keysight E8718A Radar Target Simulator User Guide...
Getting Started Inspect the Instrument for Damage After unpacking the E8718A, carefully inspect the unit for any shipping damage. Report any damage to the shipping agent immediately, as such damage is not covered by the warranty. The warranty also does not cover: –...
Getting Started Return the Instrument for Service Should it become necessary to return the E8718A for repair or service, follow the steps below: 1 Review the warranty information shipped with your product. 2 Contact Keysight to obtain a Return Material Authorization (RMA) and return address.
Getting Started Verify the Shipment Contents The following items are included in the E8718A shipment: – E8718A Radar Target Simulator Quick Reference Guide (P/N: E8718-90006) - printed copy of this document – Calibration certificate Keysight E8718A Radar Target Simulator User Guide...
Page 22
Getting Started THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK. Keysight E8718A Radar Target Simulator User Guide...
Page 23
Keysight E8718A Radar Target Simulator User Guide System Overview System Intended Use Hardware Setup Test System Specifications This chapter describes the usage, setup, and specifications of the E8718A.
The RTS provides a simulation of distance, object size, and speed, accurately and dynamically. In the design verification environment, the E8718A SFP utilizes a simple interface, whereby you may set the required simulation value. Once the setting is complete, all you need to do is trigger the test and provide a frequency-modulated continuous-wave (FMCW) signal from the automotive radar sensor.
The RF cables provided with the system should NOT be removed or changed to NOTE different length or type. This is will affect the validity of the calibration and thus performance of the systems. Keysight E8718A Radar Target Simulator User Guide...
177 mm x 425 mm x 422 mm System Weight (kg) 18 kg Size and Weight (3-Channel) System Dimension (H x W x D) 220 mm x 425 mm x 580 mm System Weight (kg) 31.4 kg Keysight E8718A Radar Target Simulator User Guide...
Page 27
System Overview Refer to E8718A datasheet for the latest product specifications. NOTE Keysight E8718A Radar Target Simulator User Guide...
Page 28
System Overview THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK. Keysight E8718A Radar Target Simulator User Guide...
Page 29
Software Installation Software License Redemption Software License Installation or Upgrade Soft Front Panel (SFP) on E8718A Fixed Range Registration Access to E8718A SFP This chapter describes the system requirements, the software installation, and the Soft Front Panel (SFP) of the E8718A.
System Software and User Application System Requirements The following table lists the minimum system requirements for the E8718A software. Windows ® 7 (32-bit and 64-bit) and above Operation system Starter, Home Basic, Home Premium, Professional, Ultimate, or Enterprise 1 GHz 32-bit (x86) or Processor speed 1 GHz 64-bit (x64);...
System Software and User Application Change the Original Password at Factory Settings Keysight recommends you change the original password at factory settings for “User”. The following steps detail how to change the password. 1 Press the Ctrl + Alt + Del keys together on your keyboard to get to the security screen.
Software Installer Location Software installer on E8718A shared folder You can find the software installer (KeysightE870xA.exe) in the E8718A shared folder (\\Keysight-E8718A\Documents\). 1 Connect your PC to the LAN 2 port of E8718A via the RJ45 connector as shown in Figure 3-2.
This installation includes the libraries and related user documentation for the E8718A. 1 Launch the downloaded installer. 2 Follow the installer prompts to install all software and documentation for the E8718A Radar Target Simulator. Figure 3-2 InstallShield Wizard for Keysight E870xA Keysight E8718A Radar Target Simulator User Guide...
Page 34
Header files C:\Program Files (x86)\Keysight\E870x\include Libraries linker files C:\Program Files (x86)\Keysight\E870x\lib Example Programs C:\Program Files (x86)\Keysight\E870x\Examples Libraries file information can be found in programming guide E870x Radar Target NOTE Simulator Programming Guide (P/N: E8718-90003) Keysight E8718A Radar Target Simulator User Guide...
Software License Redemption 1 Log into Keysight's licensing website to redeem your license at www.keysight.com/find/softwaremanager. 2 Enter the following information that is found from the E8718A certificate: – Keysight Order Number – Keysight Certificate Number 3 Get the Host ID from the E8718A's SFP.
3-3, click the Load button to select the license file you redeemed in “Software License Redemption” on page 35. 2 Click the Install button to install the license file. Figure 3-3 License installation dialog Keysight E8718A Radar Target Simulator User Guide...
Soft Front Panel (SFP) on E8718A 1 Enter the relevant parameters in the SFP screen in Figure 3-4 and run the RTS by clicking Apply. Figure 3-4 SFP Screen 2 Refer to Table 3-2 for the configuration limits. Keysight E8718A Radar Target Simulator User Guide...
System Software and User Application Fixed Range Registration This registration is only applicable for the fixed range license option. E8718A only runs simulation with the registered fixed range values. For example, 3 fixed range licenses allow you to register any 3 fixed range values within the 4 m to 300 m range.
System Software and User Application Figure 3-6 Installing License dialog with Register Fixed Range button Keysight E8718A Radar Target Simulator User Guide...
Remote Access - Windows Remote Desktop Connect monitor, USB mouse and USB keyboard 1 Connect monitor, USB mouse, and USB keyboard to E8718A rear panel before powering up the E8718A. E8718A does not have VGA hot plug support. Monitor must be connected to WARNING E8718A before turning on the power of the E8718A unit.
3 Open Remote Desktop Connection as shown in Figure 3-9 by clicking the Window Start button. In the search box, type Remote Desktop Connection, and then, in the list of results, click Remote Desktop Connection. Keysight E8718A Radar Target Simulator User Guide...
Page 44
Computer box and User name box. Computer: 169.254.67.122 or Keysight-E8718A User name: User Password: 123456 E8718A LAN2 default IP address is set to 169.254.67.122. NOTE 5 Then click Connect button to start remote desktop session. Windows Security dialog box as shown in Figure 3-10 will prompt for password.
System Software and User Application Figure 3-10 Windows Remote Desktop Connection - Windows Security Keysight E8718A Radar Target Simulator User Guide...
Page 47
Keysight E8718A Radar Target Simulator User Guide Operation and Performance Verification Verify the Operation of the E8718A Operating the Laser Conduct Performance Verification (Optional) This chapter describes how to verify the operation and performance of the E8718A.
Follow the steps below to verify the basic operations of the E8718A: 1 Connect a power cord to the AC power inlet at the rear of the E8718A. 2 Switch on the power switch. You may apply 100 to 240 V, 50/60 Hz AC single phase (300 W maximum).
Figure 4-1 Position of laser push button switch for horizontal antenna Figure 4-2 Position of laser push button switch for vertical antenna The laser points at the location where the E8718A antenna is pointing. Keysight E8718A Radar Target Simulator User Guide...
WARNING Follow the steps below to operate the laser: 1 Ensure E8718A is powered up. Press the Laser ON/OFF push button to switch on the laser. 2 Adjust the position of Automotive Radar Sensor (unit under test) so that the red dot emitted from the laser is pointing at it.
Figure 3-4. The E8718A operating software provides control over the system. 2 Use the E8718A operating software as a learning tool to experience the E8718A capability and behavior through a user-friendly SFP. 3 Prepare the required hardware for the performance verification. A typical setup...
Page 52
Operation and Performance Verification Verifying the functionality of the E8718A requires a known working automotive NOTE radar sensor. The Distance (D) between the E8718A and the automotive radar sensor should correlate with the Chamber Range Setup in the operating software.
Need help?
Do you have a question about the E8718A and is the answer not in the manual?
Questions and answers