Dantherm KONTROLLELEKTRONIK FCB 773 Service Manual
Dantherm KONTROLLELEKTRONIK FCB 773 Service Manual

Dantherm KONTROLLELEKTRONIK FCB 773 Service Manual

Free cooling box

Advertisement

Quick Links

Free Cooling Box FCB 773
Service manual
U:\Manuals\FCB\FCB 773 -EN-.pdf
1/10
2009-02-05

Advertisement

loading

Summary of Contents for Dantherm KONTROLLELEKTRONIK FCB 773

  • Page 1 Free Cooling Box FCB 773 Service manual U:\Manuals\FCB\FCB 773 -EN-.pdf 1/10 2009-02-05...
  • Page 2: Table Of Contents

    In the table below you can see how to contact the manufacturer and sales offices. Contact Office Sweden Norway Denmark Name Kontrollelektronik A/S Dantherm avd. Dantherm Air Handling A/S Dantherm Air Handling AB Kontrollelektronik Address Virkesgatan 5 Postboks 147 / Marienlystvej 65 Storgatan 29 SE-614 31 Söderköping...
  • Page 3: Introduction

    Kontrollelektronik Dantherm Air Handling AB. The service manual is subject to changes without notice. Reservations Kontrollelektronik Dantherm Air Handling AB, Virkesgatan 5, SE-614 31 Söderköping CE - Declaration of hereby declare that the unit are in conformity with the following directives:...
  • Page 4: Technical Data

    Technical data The table below shows the performance of the Free cooling unit: Free Cooling Performance 48V DC Specification 230V AC Air flow 622 l/s (2240 m 622 l/s (2240 m Free cooling capacity 746 W/°C 746 W/°C Free cooling capacity at Δt=7°C 5,2 kW 5,2 kW Power consumption...
  • Page 5 Technical data, continued In the table below the data of the filter are specified: Filter data Compact filter Specification Type Compact filter Removal efficiency Dimensions 670 x 295 x 70 Total Area 4,3 m Filter monitor setting 85 Pa (at 6V DC signal) The table below show the components and types for controlling of the Free cooling unit: Controlling 48V DC...
  • Page 6: Dimensions

    Dimensions This drawing illustrates the dimensions of the Free cooling unit: Illustration Side Front U:\Manuals\FCB\FCB 773 -EN-.pdf 6/10 2009-02-05...
  • Page 7: Flow Illustration

    Flow illustration The picture below schematically shows the air flow. Flow Alternative inlet Default inlet U:\Manuals\FCB\FCB 773 -EN-.pdf 7/10 2009-02-05...
  • Page 8: Wiring Diagram

    Wiring diagram Fans + Brown Main supply - Blue 48VDC 2x1,5 0-10V BCT 48 Y1-2 0-10V Brown Brown 100% White 2x0,5 White Blue White Green 1x4x0,5 Room termostat Violet Blue Fan alarm output White BCT 48 090120 Green Power alarm output Violet U:\Manuals\FCB\FCB 773 -EN-.pdf...
  • Page 9: Preventive Maintenance

    Switch off all power to the unit before working on the unit! Caution! Make sure that all work has been performed before switching on the power again. Kontrollelektronik Dantherm Air Handling AB recommends that intervals between Interval preventive maintenance do not exceed 1 year. It is also our recommendation that the site and unit is examined closely during the first preventive maintenance to determine whether the interval is too long.
  • Page 10: Spare Parts List

    In the table below you can see how to contact the manufacturer and sales offices. Contact Office Sweden Norway Denmark Name Kontrollelektronik A/S Dantherm avd. Dantherm Air Handling A/S Dantherm Air Handling AB Kontrollelektronik Address Virkesgatan 5 Postboks 147 / Marienlystvej 65 Storgatan 29 SE-614 31 Söderköping...