Boss Celsius Platinum PL13HP Installation & User Manual

Boss Celsius Platinum PL13HP Installation & User Manual

Premium full inverter heat pump

Advertisement

Quick Links

Installation &
User Manual
PREMIUM FULL INVERTER HEAT PUMP
1
Celsius Platinum Inverter Heat Pump
Installation & User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Celsius Platinum PL13HP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Boss Celsius Platinum PL13HP

  • Page 1 Installation & User Manual PREMIUM FULL INVERTER HEAT PUMP Celsius Platinum Inverter Heat Pump Installation & User Manual...
  • Page 2: Table Of Contents

    TABLE OF CONTENT FOR USERS 1. General Information 1.1 Contents 1.2 Operating condition 1.3 Advantages of different modes 1.4 Kind Reminder 2. Operations 7-10 2.1 Notice before using 2.2 Operation Instructions 2.3 Maintenance and winterising 3. Technical Specification FOR INSTALLERS AND PROFESSIONALS 4.
  • Page 3: General Information

    1. GENERAL INFORMATION 1.1 CONTENTS After unpacking, please check that you have all the following components. 1.2 OPERATING CONDITIONS AND RANGE Items Range Operating Range Air Temperature C - 43 Heating C - 40 Temperature Setting Cooling C - 35 The heat pump will have ideal performance in the operation range Air 15 C ~ 25 1.3 ADVANTAGES OF DIFFERENT MODES...
  • Page 4: Kind Reminder

    1.4 KIND REMINDER ATTENTION This heat pump has power-off memory function. When the power is recovered, the heat pump will restart automatically. 1.4.1 The heat pump can only be used with pool water. It can NEVER be used to heat or cool other flammable or turbid liquid.
  • Page 5 1.4.4 Do not obstruct or insert any objects into inlet or outlet of the heat pump. The efficiency may be reduced or even stopped. 1.4.5 To avoid fire hazards, do not store or use combustible gas or liquids such as thinners, paints or fuels near the heat pump.
  • Page 6 1.4.7 The main power supply switch should be out of the reach of children. 1.4.8 Please disconnect the heat pump from the power supply during electrical storms. 1.4.9 Please note that following codes are not failures. Codes No water flow Anti-freezing reminder Out of the operating range Insufficient water flow or pump blocked...
  • Page 7: Operations

    2. OPERATIONS 2.1 NOTICE BEFORE USING To optimise the life-cycle of the system, the user is advised to start the water pump before the heat pump, and turn off the heat pump before the water pump. Check for any water leakage in connecting pipework, then turn on the power supply, press the ON/OFF button of the heat pump, and set desired temperature.
  • Page 8 NOTE Screen lock a) If no operation in 30 seconds, screen will be locked. b) When Heat Pump is off, screen will be dark and “0%” will be displayed. Screen unlock a) Press for 3 seconds to unlock screen. The screen will illuminate b) All other buttons are only functional after the screen is unlocked.
  • Page 9 Power On Press for 3 seconds to unlock screen, then press to power on heat pump. Adjust Set Temperature When screen is unlocked, press to display or adjust the set temperature. Mode Selection Press to select modes. a) Auto: Adjustable temperature range 12~40 b) Heating: Adjustable temperature range 18~40 c) Cooling: Adjustable temperature range 12~30 Turbo/Smart/Silence mode selection:...
  • Page 10: Maintenance And Winterising

    2.3 MAINTENANCE AND WINTERISING 2.3.1 Maintenance ATTENTION Please don’t forget to cut off power supply to the heat pump Regularly clean the evaporator with household detergents or clean water. NEVER use gasoline, thinners or any similar fuel. Check bolts, cables and connections regularly. Every three months spray a surface insecticide on the surfaces around the unit to prevent and and insect ingress.
  • Page 11: Technical Specification

    3. TECHNICAL DATA OVERVIEW Description PL13HP PL17HP PL21HP PL26HP PL32HP Maximum Pool Volume (m³) - Cool Climate Maximum Pool Volume (m³) - Warm Climate Operating air temperature -15~43 Performance Condition: Air 26°C, Water 26°C, Humidity 80% Heating capacity in Smart mode 13.8 17.5 21.5...
  • Page 12: Transportation

    4. TRANSPORTATION When storing or moving the heat pump, please ensure the unit remains in an upright position at all times. When moving the heat pump, do not lift the water union. This will damage the titanium heat exchanger. Celsius Platinum Inverter Heat Pump Installation &...
  • Page 13: Installation And Maintenance

    5. INSTALLATION AND MAINTENANCE ATTENTION It is strongly advised that the heat pump is installed by a professional. Unqualified installations may result in damage to the heat pump and/or safety risks to the user. 5.1 NOTICE BEFORE INSTALLATION 5.1.1 Plumbing connections must be made with solid PVC pipe. Usage of flexible PVC pipe is not recommended. Celsius Platinum Inverter Heat Pump Installation &...
  • Page 14: Installation Instructions

    5.2 INSTALLATION INSTRUCTIONS 5.2.1 Location and size ATTENTION The heat pump should be installed in a place with good ventilation. The heat pump is usually installed within a perimeter area extending 7.5m from the swimming pool. The greater the distance from the pool, the greater the heat loss in the pipes. As the pipes are mostly underground, the heat loss is low for distances up to 30m (15m from and to the heat pump;...
  • Page 15 CHECK VALVE INSTALLATION AUTOMATIC DOSING Sanitation and automatic dosing systems must be plumbed after the heat pump. A check valve must be installed between the sanitation/automatic dosing system and the heat pump to prevent chemicals returning to the heat pump. Failure to observe this instruction will void the warranty.
  • Page 16 ADJUSTING THE BYPASS Celsius Platinum Inverter Heat Pump Installation & User Manual...
  • Page 17 Use the following procedure to adjust the bypass: Close the valve to Position A Turn on the circulation pump Slowly open the valve towards Position B until the display error code of “E6” disappears. Once the message clears, the default display is the current water temperature. Starting sequence will now begin.
  • Page 18 DIMENSIONS Unit = mm PL13HP PL17HP PL21HP PL26HP 1125 PL32HP 1074 *Above data is subject to modification without notice. 5.2.2 Heat Pump Installation When the heat pump is running, condensation will occur and drain from the bottom of the unit. This is completely normal. However, consideration should be made for how to drain the condensation away.
  • Page 19 WIRING DIAGRAM For power supply: 240V 50Hz Swimming Pool Heat Pump Wiring Board Distribution Box (Customer prepare) Power Cord Power Supply Fuse Breaker 240V 50Hz Earthing For power supply: 380V 50Hz Swimming Pool Heat Pump Wiring Board Distribution Box (Customer prepare) Power Cord Power Supply Fuse...
  • Page 20: Trial After Installation

    OPTION FOR PROTECTING DEVICES AND CABLE SPECIFICATION Model PL13HP PL17HP PL21HP PL26HP PL32HP Rated Current A 15.0 19.0 22.5 24.5 28.5 Breaker Rated Residual Action Current mA Fuse A 15.0 19.0 22.5 24.5 28.5 Power Cord (mm 3x2.5 Signal Cable (mm 3x0.5 3x0.5 3x0.5...
  • Page 21: Trouble Shooting Guide

    6. TROUBLE SHOOTING GUIDE Failure Reason Solution No power Wait until the power recovers Power switch is off Switch on the power Heat pump doesn’t run Fuse burned Check and change the fuse The breaker is off Check and turn on the breaker Evaporator blocked Remove the obstacles Fan running but...
  • Page 22: Error Codes

    7. ERROR CODES Display Failure Description High pressure protection Low pressure protection Phases lack protection (three phase model only) Water outlet temp too high or too low protection High exhaust temp protection Evaporator overheat protection (only at cooling mode) Controller communication failure Water inlet temp sensor failure Water outlet temp sensor failure Gas exhaust temp sensor failure...
  • Page 23: Wifi Setting

    8. WIFI SETTING App Download iPhone please download from Android mobile please download from Account Registration Registration by mobile number/email Celsius Platinum Inverter Heat Pump Installation & User Manual...
  • Page 24 WIFI SETTING Mobile number registration Create family Please set family name and choose the room of device Celsius Platinum Inverter Heat Pump Installation & User Manual...
  • Page 25 WIFI SETTING APP Binding Please make sure your mobile phone has connected to Wifi Wifi Connection Press for 3 seconds after screen unlock, will be flashing to enter Wifi binding program. Click “Add device”, follow indication to finish binding. display on the screen once Wifi connection success.
  • Page 26 WIFI SETTING Operation For heat pump with Heating function only. More share devices Indicate the status of heating Heating capacity % Select C C / F Current swimming pool water temperature The setting temperature Timer Select Smart/ Silence Mode ON/OFF Celsius Platinum Inverter Heat Pump Installation &...
  • Page 27 WIFI SETTING Share devices to your family members After binding, if your family members also want to control the device. Please let your family members register the APP first, and then the administrator can operate as below: Celsius Platinum Inverter Heat Pump Installation &...
  • Page 28 WIFI SETTING Then your family members can log in as below: NOTE • The weather forecast is just for reference. • APP is subject to updating without notice. Celsius Platinum Inverter Heat Pump Installation & User Manual...
  • Page 29 1300 786 489 Scan to access Boss Polymer Technologies Pty Ltd Terms and Conditions of Trade Celsius Platinum Inverter Heat Pump Installation & User Manual...

Table of Contents