Download Print this page

M-S Cash Drawer EP-125KSC Instructions

Ksc type interface

Advertisement

Quick Links

Introduction
M-S Cash Drawer interface type KSC enables the cash drawer to be controlled by a
computer's serial port and incorporates the following unique features:
No external power source or AC adaptor is required for standard RS-232 serial
interfaces.
Selectable noise filtering circuitry to prevent false openings.
Standard "Drawer Open" signal which can be used to indicate the drawer's
status.
Options
Integration, Test and Troubleshooting software for IBM compatible MS-DOS
systems is available for all M-S Cash Drawer interfaces. The software may be
ordered for $5 plus shipping.
KSC equipped cash drawers require an interface cable between the cash drawer
and the host computer. Three versions of this interface cable are available from
M-S Cash Drawer: DB25 female, DB9 female, and Unterminated.
The KSC is powered directly from the computer's serial interface card for most
installations. Some POS software turns off the serial interface power between
drawer openings.
Optional driver software to monitor and power the serial interface can be
ordered from M-S Cash Drawer for $5 plus shipping for these installations. An
optional AC adapter can be ordered for $10 plus shipping.
Installation - Serial Interface
This installation uses a dedicated RS-232 serial port on your computer or terminal to
send an "open" command to the trigger board in the cash drawer. Any data sent on this
port will open the cash drawer. (If it is necessary to independently operate a printer or
other device on the same serial port, the KSI interface type is required).
M-S Cash Drawer Corporation
KSC type interface instructions

Advertisement

loading

Summary of Contents for M-S Cash Drawer EP-125KSC

  • Page 1 KSC type interface instructions Introduction M-S Cash Drawer interface type KSC enables the cash drawer to be controlled by a computer's serial port and incorporates the following unique features: No external power source or AC adaptor is required for standard RS-232 serial interfaces.
  • Page 2 Step by Step 1. Connect the interface cable between the cash drawer and the computer's serial port. Mini Din Color Connector Pin # Brown Shell Green Blue Black White Jumper 1* Jumper 2* * Jumpers simulate hardware handshaking 2. Set DIP switches. There are four configuration switches visible on the back of the cash drawer The ON direction is noted on the switch by an arrow.
  • Page 3: Troubleshooting

    Try setting terminal mode switch setting - SW2 ON and SW1 OFF Reset to standard settings if drawer does not open. Try using the driver software or an AC adapter (see OPTIONS above). The adapter must be a special negative tip adapter available from M-S Cash Drawer.