Nordson EFD Optimum Ceramic MicroDot 7364054 Instructions

Advertisement

Cleaning Optimum Ceramic MicroDot Tips
Instructions

Introduction

To precisely dispense accurate, small amounts of fluid, the Optimum
extremely small opening. This opening can become clogged or blocked by very small contaminants which
can adversely affect dispensing results.
Tip contamination, particularly in the fluid flow path, is manifested by the following symptoms:
• Poor dispensing
• No fluid flow, caused by clogging of the nozzle orifice

Recommended Cleaning Schedule / Cycles

Cleaning and maintenance intervals vary depending on operating conditions. Testing has shown that MicroDot ceramic tips
can survive 10 cleaning cycles without loss of performance.

Cleaning Tools

• Valve disassembly / reassembly tools (refer to the valve manual)
• Tweezers
• Acetone
• Compressed air supply
• Ultrasonic cleaner

Three Steps for Cleaning MicroDot Tips

(1) Clean the Fluid Path by Purging the Tip

If the tip is not clogged, purge the tip with a cleaning fluid or solvent that is compatible with your dispensing fluid. Purging
can be performed with the tip assembled on the valve or manually if the tip has been disassembled from the valve.
NOTES:
• Refer to the valve manual for disassembly and reassembly procedures.
• The MicroDot tip can withstand repeated purging cycles with acetone. Before using acetone, refer to the Technical Data
Sheet (TDS) or Safety Data Sheet (SDS) for your dispensing fluid to ensure that it is compatible with acetone.
®
Ceramic MicroDot
tip has an
Continued on next page

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Optimum Ceramic MicroDot 7364054 and is the answer not in the manual?

Questions and answers

Summary of Contents for Nordson EFD Optimum Ceramic MicroDot 7364054

  • Page 1 Cleaning Optimum Ceramic MicroDot Tips Instructions Introduction To precisely dispense accurate, small amounts of fluid, the Optimum ® Ceramic MicroDot ™ tip has an extremely small opening. This opening can become clogged or blocked by very small contaminants which can adversely affect dispensing results. Tip contamination, particularly in the fluid flow path, is manifested by the following symptoms: •...
  • Page 2 1,000 cps. Most other fluids will require a longer cleaning time. Sometimes multiple cycles of ultrasonic cleaning along with compressed-air cleaning are required to fully disperse cured material. For Nordson EFD sales and service in over 40 countries, contact Nordson EFD or go to www.nordsonefd.com. Global 800-556-3484;...

This manual is also suitable for:

Optimum ceramic microdot 7364386Optimum ceramic microdot 7364540Optimum ceramic microdot 7018395Optimum ceramic microdot 7018417Optimum ceramic microdot 7015236Optimum ceramic microdot 7018424 ... Show all

Table of Contents