Caen ELS CT-600 User Manual

Dc current transducers

Advertisement

Quick Links

<
DC Current Transducers
CT-600
CT-1000
User's Manual
All Rights Reserved
© CAEN ELS s.r.l.
Rev. 1.7 – November 2022

Advertisement

Table of Contents
loading

Summary of Contents for Caen ELS CT-600

  • Page 1 < DC Current Transducers CT-600 CT-1000 User’s Manual All Rights Reserved © CAEN ELS s.r.l. Rev. 1.7 – November 2022...
  • Page 2 CT-600/CT-1000 User’s Manual CAEN ELS s.r.l. Via Vetraia, 11 55049 Viareggio (LU) - Italy Mail: info@caenels.com Web: www.caenels.com...
  • Page 3: Table Of Contents

    CT-600/CT-1000 User’s Manual Table Of Contents INTRODUCTION ....................9 < ............. 9 URRENT RANSDUCERS VERVIEW CT-600/CT-1000 M ..........10 ODELS AND ERSIONS INSTALLATION AND OPERATION ............12 ..............12 ECHANICAL ONSIDERATIONS ..................13 ONNECTOR INOUT ................14 ECONDARY SIDE IGNALS 2.3.1 Power Supply ...................
  • Page 4 CT-600/CT-1000 User’s Manual Document Revisions Revision Date Comment September 16 2014 Document created September 23 2014 Added power supply recommendation section November 3 2014 Manual graphics changed January 27 2016 Table 3 updated July 8 2016 Added data to technical specifications...
  • Page 5 – Power Supply Recommendations PS1215 We strongly recommend using this product with the CAEN ELS PS1215 power supply, which has been especially deigned in order to obtain low-noise operation and it is suited for DCCT measurement system where switching power supplies could corrupt measuring accuracy, precision and noise.
  • Page 6 User's Manual before any kind of operation. CAEN ELS d.o.o. reserves the right to change partially or entirely the contents of this Manual at any time and without giving any notice. Disposal of the Product The product must never be dumped in the Municipal Waste.
  • Page 7 CT-600/CT-1000 User’s Manual Read over the instruction manual carefully before using the instrument. The following precautions should be strictly observed before using the device: • Do not use this product in any manner not WARNING specified by the manufacturer. The protective features of this product may be impaired if it is used in a manner not specified in this manual.
  • Page 8 CT-600/CT-1000 User’s Manual The following table shows the general environmental requirements for a correct operation of the instrument: Environmental Conditions Requirements Operating Temperature 0°C to 50°C Operating Humidity 30% to 85% RH (non-condensing) Storage Temperature -10°C to 60°C Storage Humidity...
  • Page 9: Introduction

    CT-600/CT-1000 User’s Manual 1. Introduction < This chapter describes the general characteristics and main features of the current transducers. < Current Transducers Overview < current transducers family is based on a closed loop technology that allows accurate and precise monitoring of DC and AC currents with high bandwidth.
  • Page 10: Ct-600/Ct-1000 Models And Versions

    “V” model. Connections for power supply and output signals are available through a standard D-SUB connector (also known as “DE-9”). The different models and versions of the CT-600 and CT-1000 are summarized in the following table ( Table 1...
  • Page 11 CT-600/CT-1000 User’s Manual Front view of a CT-600/CT-1000 current transducer is presented in Figure 1 < Figure 1: front view of a CT-600 or CT-1000 current transducer Rear view of the same current transducer, where self-threading holes for screws are visible, is presented in Figure 2 <...
  • Page 12: Installation And Operation

    2.1 Mechanical Considerations Each version of the CT-Series current transducer presents an embossed “arrow” with the CAEN ELS logo on one side of the plastic casing that indicates the verse of the positive primary current measurement. This arrow can be seen in...
  • Page 13: Connector Pinout

    CT-600/CT-1000 User’s Manual 2.2 Connector Pinout The CT-600 and CT-1000 have a standard D-SUB 9-pin (or, commonly referred to as “DE-9”) in both their current output and voltage output versions. The standard pin numbering to refer to is herein presented in...
  • Page 14: Secondary-Side Signals

    Maximum current that can be drawn from each one of these supply voltages is of 450 mA for CT-600 and 550mA for CT-1000 (a maximum of 50 mA for supplying the internal electronics circuits and a maximum of 400 mA for CT-600 or 500 mA for CT-1000 for the secondary current).
  • Page 15: Status Signal

    CT-600/CT-1000 User’s Manual This behavior can be resumed in the gain parameter G, in [V/A], expressed as the ratio between the transducer output voltage (�� − �� ) and the primary current �� �� ������ �� �� �� − ��...
  • Page 16 CT-600/CT-1000 User’s Manual Figure 6: OUT OK signals connections as digital interfacing to +3.3V Note that the connection scheme presented in is referred to the GND Figure 5 potential and the OK_SIGNAL is at low level (<0.4V) if the current transducer is correctly working while it is at high level (>14.5V) when the transducer is not.
  • Page 17: Mounting

    CT-600/CT-1000 User’s Manual 2.4 Mounting The current transducers can be mounted in different configurations, depending on user’s needs and opportunities, but heatsink shall never be faced to the floor. The transducers are designed to be used in rack-mount applications, by means of any of the two (2) different 4-hole patterns placed in different sides of the mechanical case.
  • Page 18: Primary Current Path

    CT-600/CT-1000 User’s Manual • UNI 8119 • DIN 7504 - P • ISO 15482 2.5 Primary Current Path A non-symmetrical layout of the primary current return path may degrade the accuracy and the noise of the current transducer. A cross section of the transducer plastic case illustrates what happens if the primary current is not equally distributed over the perimeter of the current transducer head.
  • Page 19: Full-Scale Current

    Figure 11: primary full-scale current scaled by a factor 2 (2 primary turns - left) and scaled by 3 (3 primary turns - right) Do not apply rated nominal full-scale primary current (for example 600A for CT-600) when carrying out multiple turns on primary conductor hole.
  • Page 20: Ordering Options

    CT-600/CT-1000 User’s Manual 3. Ordering Options The CT-600 current transducers have two different versions differing by the secondary output signal types. The ordering code is formatted as follows: Output Version empty = current output = voltage output NOTE: fields/characters shaded in grey color are fixed.
  • Page 21: Technical Specifications

    CT-600/CT-1000 User’s Manual 4. Technical Specifications Technical Specifications for current transducers of the CT-600 and CT-1000 series are herein presented. Technical Specifications CT-600 CT-1000 Current Transformation Ratio - N 1:1500 1:2000 Maximum DC Primary ±600 A ±1000 A Current - I...
  • Page 22: Equivalent Input Noise

    Hole Diameter - Ø Maximum Weight 600 g * These specifications are guaranteed only when the CT sensor is used with the dedicated CAEN ELS PS1215 power supply Table 3: Technical Specifications 4.1 Equivalent Input Noise The typical equivalent input noise of the transducers is hereafter presented as a function of the measuring bandwidth and of the output version.
  • Page 23 CT-600/CT-1000 User’s Manual Noise CT-600 Noise CT-1000 2000 20000 Bandwidth (Hz) Figure 12: Equivalent input noise graph (typical values)
  • Page 24: Insulation Characteristics

    CT-600/CT-1000 User’s Manual 4.2 Insulation characteristics In the following table are represented the insulation characteristics of the CT- 600 and CT-1000 current transducers. Parameter Value Reference IEC 61010-1 conditions Rated insulation voltage (RMS), 2000 V - over voltage cat III...
  • Page 25: External Shunt Resistor

    CT-600 [mA] Figure 13: CT-600 maximum external shunt resistor (Current version only) CT-1000 150 175 200 225 250 275 300 325 350 375 400 425 450 475 500...
  • Page 26: Mechanical Dimensions

    CT-600/CT-1000 User’s Manual 5. Mechanical Dimensions The mechanical dimensions of the CT-600 and CT-1000 case are hereafter presented (all dimensions are in mm). Figure 15: Mechanical drawings...

This manual is also suitable for:

Ct-1000