Model No. Indoor Unit Outdoor Unit SI-10T3SDIA series SO-10T3SDIA series SI-10T5SDIA series SO-10T5SDIA series SI-15T3SDIA series SO-15T3SDIA series ACI2PR22201...
Page 2
• Please note that the indication is on display to start the unit. 3 Select the desired temperature • Selection range: 16 °C ~ 30 °C. • Operating the unit within the recommended temperature range may save energy. COOL: 24 °C ~ 28 °C. DRY : 1 °C ~ 2 °C lower than room temperature.
Page 3
Emergency operation key....13-14 16-18 • Remote control • AAA or R03 batteries • Remote control holder TEMP • Screws for remote control MODE AIR SWING holder GLACIER FAN SPEED • PM 2.5 Filter SLEEP DISPLAY CLEAN CANCEL CHECK LOCK RESET...
Safety precautions Prevent water leakage by ensuring drainage 2. Servicing 2-1. Service personnel pipe is: • Any qualifi ed person who is involved with - Connected properly, working on or breaking into a refrigerant - Kept clear of gutters and containers, or circuit should hold a current valid certifi cate - Not immersed in water from an industry-accredited assessment...
Page 10
TEMP MODE AIR SWING GLACIER FAN SPEED SLEEP DISPLAY CLEAN CANCEL CHECK LOCK RESET...
Page 12
FAULT DETAILS LIGHT DISPLAY FLASH H 00 No fault Outdoor EEPROM fault H 11 Indoor to Outdoor communication fault F9 3 Compressor starting abnormal Compressor out-of-step abnormal IPM module fault Compressor shell temperature overheat protection H 15 Compressor discharge temperature sensor fault Compressor Suction temperature sensor fault H 28 Outdoor condenser temperature sensor fault...
Page 13
To select operation mode AUTO - For your convenience Unit run with optimised settings. You can change the temperature according to your comfort. Remote control COOL - To enjoy cool air display To reduce power consumption during COOL mode, Remote control use curtains to screen off sunlight and outdoor heat.
To set the timer To select fan speed To turn ON and OFF the unit at a preset times. (Remote control display) AUTO QUIET (Low) (Medium) (High) • For AUTO, the indoor fan speed is automatically adjusted according to the operation mode. CANCEL To adjust airflow direction (Remote control display)
BEE Regulation Testing Guidelines Cooling Capacity Test Method Cooling Capacity Test Method QUIET CLEAN (For Full Load) QUIET CLEAN (For Half Load)
Page 20
Do’s & Don’t: E-waste (Management ) Amendment Rules 2018 S.No. Do's Don't All electrical and electronic products are required The product should not be opened by the User to be handed over only to the Authorized himself / herself, but only by authorized service recycler.