Gas sterilizer/aerator

Advertisement

3M
Steri-Vac
TM
TM
8XL Gas Sterilizer/Aerator
Operator's Manual
3Health Care

Advertisement

Table of Contents
loading

Summary of Contents for 3M Health Care Steri-Vac 8XL

  • Page 1 Steri-Vac 8XL Gas Sterilizer/Aerator Operator’s Manual 3Health Care...
  • Page 3 Please read this manual carefully to learn how to correctly operate and maintain the 3M Steri-Vac 8XL Gas Sterilizer/Aerator. Incorrect operation may lead to sterilization failure or serious personal injury. This manual explains the function of the sterilizer/aerator, how to correctly sterilize heat-and/or moisture-sensitive devices, and how to maintain the sterilizer/aerator.
  • Page 5: Table Of Contents

    Table of Contents TABLE OF CONTENTS INTRODUCTION Intended Use ……………………………………. Features and Benefits ……………………………………. General Information ……………………………………. 3M™ Steri-Gas™ EO Cartridge 8-170 Label ……………………………………. HEALTY & SAFETY INFORMATION Toxicity ……………………………………. Flammability ……………………………………. Ethylene Oxide Leaks or Spills ……………………………………. Agency Listings …………………………………….
  • Page 7: Intended Use

    Steri-Vac 8XL Gas Sterilizer/Aerator Introduction INTRODUCTION Intended Use: The 3M™ Steri-Vac™ 8XL gas sterilizer/aerator is a compact unit designed to sterilize heat- and/or moisture-sensitive devices. This gas sterilizer/aerator is intended for INDOOR USE ONLY. Environmental Operating Conditions Environmental Condition Condition Range...
  • Page 8: Features And Benefits

    (such as Throughout the cycle, the chamber remains at negative pressure relative to the room so gas can 3M™ Comply™ EO Monitor Tape or 3M™ not escape into the sterilization work area. If a Comply™ EO Indicators) should be used to leak failure does occur in the chamber, room air ensure that sterilization parameters are met.
  • Page 9: General Information

    3M™ Steri-Gas™ EO Cartridge 8-170 100% ethylene oxide (EO). Weight of gas........170 grams Minimum gross weight..... 185 grams Sterilant Specifications Refer to the 3M Steri-Gas Consumer Product Profile. Shelf Life and Gas Weight Refer to the 3M Steri-Gas Consumer Product Profile.
  • Page 10: Steri-Gas™ Eo Cartridge 8-170 Label

    Introduction Steri-Vac 8XL Gas Sterilizer/Aerator FEATURES & BENEFITS⎯ETHYLENE OXIDE STERILIZATION ™ ™ Steri-Gas EO Cartridge 8-170 Label...
  • Page 11: Healty & Safety Information

    Steri-Vac 8XL Gas Sterilizer/Aerator Health and Safety Information HEALTY & SAFETY INFORMATION ⎯ETHYLENE OXIDE STERILIZATION Please read and understand all instructions before using the Steri-Vac sterilizer/aerator. The Steri-Vac sterilizer/aerator uses ethylene oxide gas to sterilize heat-and/or DANGER moisture-sensitive devices. Ethylene oxide is flammable and toxic. Follow all instructions and precautions carefully.
  • Page 12: Agency Listings

    Health and Safety Information Steri-Vac 8XL Gas Sterilizer/Aerator HEALTY & SAFETY INFORMATION ⎯ETHYLENE OXIDE STERILIZATION Agency Listings The Steri-Vac gas sterilizer/aerator is listed with Underwriters Laboratories, Inc. (UL). This internationally recognized laboratory has inspected and evaluated the Steri-Vac 8XL gas sterilizer/aerator.
  • Page 13: Operation

    Steri-Vac 8XL Gas Sterilizer/Aerator Operation OPERATION Introduction This section of the manual describes how to correctly operate the sterilizer/aerator. Included are procedures for turning on the sterilizer, preparing items for sterilization, and correctly performing the sterilization procedure. A detailed description of the controls and indicators are also provided.
  • Page 14: Operating Procedure

    Operation Steri-Vac 8XL Gas Sterilizer/Aerator OPERATING PROCEDURE Step 1 Power on the sterilizer. Turn on the power switch (located on the left side of the sterilizer). Leave the power switch on at all times to simplify operation and allow the sterilizer electronics to continually monitor sterilizer functions.
  • Page 15 Steri-Vac 8XL Gas Sterilizer/Aerator Operation OPERATING PROCEDURE Step 4 Load the sterilizer baskets. When loading items in the baskets, leave some space between each item. Place packages on edge. When arranging paper-plastic pouches, place the plastic side of one pouch against the paper side of another pouch.
  • Page 16 Operation Steri-Vac 8XL Gas Sterilizer/Aerator OPERATING PROCEDURE Step 7 Insert gas cartridge. Insert a Steri-Gas 8-170 cartridge into the retainer ring on the cartridge holder inside the chamber. Push the cartridge down and slightly inward until the cartridge “snaps” into position. DANGER DO NOT force the cartridge.
  • Page 17 Steri-Vac 8XL Gas Sterilizer/Aerator Operation OPERATING PROCEDURE Select temperature. Step 9 Press the temperature select switch until the desired sterilization/aeration temperature is displayed. Select the temperature according to manufacturer’s recommendations for the devices in the load. NOTICE If no switches are pressed within 5 minutes, the display will go into screensaver mode.
  • Page 18 Operation Steri-Vac 8XL Gas Sterilizer/Aerator OPERATING PROCEDURE Step 12 Start the sterilization cycle. Press the START switch to begin the sterilization/aeration cycle. The cycle continues automatically until completion. Front panel displays cycle sequence Precondition Phase Gas Expose Phase Aeration Phase •...
  • Page 19 Steri-Vac 8XL Gas Sterilizer/Aerator Operation OPERATION PROCEDURE Step 13 Open sterilizer door. During aeration cycle, appearance of the “door unlocked” symbol will indicate when the door can be opened. To open the door, turn the handle counter clockwise, allow approximately 30-60 seconds for the chamber pressure to equalize with the room pressure.
  • Page 20: Sterilizer Controls

    Operation Steri-Vac 8XL Gas Sterilizer/Aerator STERILIZER CONTROLS The control panel display shows status during sterilization. The following switches are used to control sterilizing operations: Power Switch. Turns the power to the sterilizer on and off. This switch should be left on at all times to simplify operation.
  • Page 21: Printer

    Steri-Vac 8XL Gas Sterilizer/Aerator Operation OPERATION⎯BUILT-IN THERMAL PRINTER Introduction The built-in thermal printer provides easy to read information on each sterilization cycle. The printout is helpful in analyzing sterilizer performance and can be retained to meet cycle verification policies. Location The printer is installed in the front of the sterilizer behind the access door for the water reservoir.
  • Page 22 This page is intentionally blank.
  • Page 23: Error Codes & Troubleshooting

    Steri-Vac 8XL Gas Sterilizer/Aerator Error Codes & Troubleshooting CAUTION & ERROR CODES Introduction The Steri-Vac gas sterilizers use an extensive list of codes to provide information to the operator. “Cautions” do not indicate a failure, but are informational messages to alert the operator to some special situation.
  • Page 24: Caution & Error Codes

    Error Codes & Troubleshooting Steri-Vac 8XL Gas Sterilizer/Aerator CAUTION & ERROR CODES To continue aerating the load This will take approximately without the alarm, turn the 60 minutes. If the gas removal handle back clockwise. The is then successful, the alarm will sound again when sterilizer will unlock the door the door is opened.
  • Page 25 Use the following tables to isolate the possible causes and corrective actions for the cautions and error codes displayed on the control panel display of the sterilizer. Contact your 3M service representative when indicated, if a code appears that is not listed, or if you have any questions. Codes with “•” are used on accessories to the Steri-Vac sterilizers.
  • Page 26 Error Codes & Troubleshooting Steri-Vac 8XL Gas Sterilizer/Aerator CAUTION & ERROR CODES CHART Self-Test Errors (Prevents the start of a cycle) Continued from previous page… • Unload door open Unload door open Close door – restart Switch failure Call Service representative •...
  • Page 27 Steri-Vac 8XL Gas Sterilizer/Aerator Error Codes & Troubleshooting CAUTION & ERROR CODES CHART Locked chamber errors (operator or service representative must restart) Code Message Possible Cause Corrective Action Final pumpdown timeout Improper air pressure (venturi systems) Check air supply, press START Vacuum system failure Call service representative Obstructed air inlet...
  • Page 28 This page is intentionally blank.
  • Page 29: Preventive Maintenance

    Performing preventive maintenance at scheduled intervals is a critical part of ensuring that the Steri-Vac sterilizer/aerator continues to produce quality results. Preventive maintenance should be performed by a trained 3M service representative or a trained maintenance person from the institution. Perform the following preventive maintenance procedures at the recommended intervals.
  • Page 30: Authorized Service

    (PMA) for purchase with the Steri-Vac equipment. The PMA assures you of periodic maintenance of your sterilizer and emergency services. Contact your local 3M Health Care service representative or the 3M Health Care Service Center at the above address for PMA information. Service Manuals Service Manuals are available for any 3M Steri-Vac gas sterilizer/aerator.
  • Page 31 ____ NOTES...
  • Page 32 NOTES ____...
  • Page 34 Health Care 3M Canada, Inc. 3M Center, Building 275-4W-02 P.O. Box 5757 St. Paul, MN 55144-1000 London, Ontario N6A 4T1 Canada Printed in U.S.A. © 3M 1999 - 2004 All Rights Reserved 1-800-228-3957 1-800-563-2921 healthcare@3M.com 70-2008-8045-1 Rev. C (POD) 7/04 www.3M.com/healthcare...

Table of Contents