  • Page 1 5S-P-003 Program Writer User Manual Version 0.07 – Oct. 14, 2022  Copyright 2022 by PADAUK Technology Co., Ltd., all rights reserved.
  • Page 2 Program Writer IMPORTATNT STATEMENT PADAUK Technology reserves the right to make changes to its products or to terminate production of its products at any time without notice. Customers are strongly recommended to contact PADAUK Technology for the latest information and verify whether the information is correct and complete before placing orders.
  • Page 3: Table Of Contents

    7. Set O/S Test and Blank Check ................... 28 8. Writer LCM Information and Buzzer Sound Table ............30 9. Appendix Descriptions ....................... 32 9.1 The difference between 5S-P-003 and 3S-P-002 ............... 32 9.2 The difference between 5S-P-003 and 5S-P-003Bx ..............32 5S-P-003-UM-EN-V007 – Oct. 14, 2022 ©...
  • Page 4 9.2 Special notes of MTP On-board writing ..................32 9.3 Special notes of voltage while On-board or Multi-Chip-IC writing (OTP / MTP) ......34 5S-P-003-UM-EN-V007 – Oct. 14, 2022 © Copyright 2022, PADAUK Technology Co. Ltd Page 4 of 34...
  • Page 5 2017/11/24 4. Amend chapter 4 5. Update the LCM signal table of chapter 7 6. Add 8.2 On-line writing 1. Update the address and telephone number of PADAUK Technology co., Ltd. 2. Update Partial pictures 0.05 2018/03/19 3. Add description of O/S check or Blank check 4.
  • Page 6: About 5S-P-003 Writer

    (6) LCM displayer: Display the information and result of writing. (7) Program button: Start writing. (8) Textool: Suitable for DIP package (available for 28 PIN at most). 5S-P-003-UM-EN-V007 – Oct. 14, 2022 © Copyright 2022, PADAUK Technology Co. Ltd Page 6 of 34...
  • Page 7: The Back

    Program Writer) (3) Power Switch: OFF/ON. (4) Semi-automatic writing connection port: About the connection method, please refer to chapter 6. 5S-P-003-UM-EN-V007 – Oct. 14, 2022 © Copyright 2022, PADAUK Technology Co. Ltd Page 7 of 34...
  • Page 8: Accessories Of Program Writer

    Or enter the home page of www.paduak.com.tw, obtain latest Program Writer version from home page > technology application > technology development tool > Program Writer. Please refer to the chapter 3. 5S-P-003-UM-EN-V007 – Oct. 14, 2022 © Copyright 2022, PADAUK Technology Co. Ltd Page 8 of 34...
  • Page 9: Functional Description

    Program Writer 2. Functional Description (A) Engineering type (B) Simple type No matter simple type or engineering type, they have the equal corresponding function. 5S-P-003-UM-EN-V007 – Oct. 14, 2022 © Copyright 2022, PADAUK Technology Co. Ltd Page 9 of 34...
  • Page 10: Steps Of Loading File

    (7) About JUMPER & IC placement position, please refer to 『JUMPER Description』. (8) When JUMPER & IC have been placed, the Program Writer’s LCM displays "IC ready". 5S-P-003-UM-EN-V007 – Oct. 14, 2022 © Copyright 2022, PADAUK Technology Co. Ltd Page 10 of 34...
  • Page 11: Blank Check

    Examples of writing (including the position of JUMPER and IC placement). Take the follow PDK file and IC for examples. File Jumper IC Shift Note Project1.PDK PMS134-S16A 5S-P-003-UM-EN-V007 – Oct. 14, 2022 © Copyright 2022, PADAUK Technology Co. Ltd Page 11 of 34...
  • Page 12 (1) Click on 『Load File』 (2) Choose JP2_83K.PDK, click on 『打开』 (3) Confirm Download OK (notice the message) (4) Confirm the information displayed on LCM. 5S-P-003-UM-EN-V007 – Oct. 14, 2022 © Copyright 2022, PADAUK Technology Co. Ltd Page 12 of 34...
  • Page 13: Rolling Code

    This function only valid while the Rolling Code grammar has been set in the loading PDK file  Please refer to the IDE User Manual to learn about the ways of setting Rolling Code. 5S-P-003-UM-EN-V007 – Oct. 14, 2022 © Copyright 2022, PADAUK Technology Co. Ltd Page 13 of 34...
  • Page 14: Read & Search

    After download the application software, you can install it. Then, you should make sure the Program Writer is connected to PC when update its version. Besides, the Program Writer will update automatically at the first execution. 5S-P-003-UM-EN-V007 – Oct. 14, 2022 © Copyright 2022, PADAUK Technology Co. Ltd Page 14 of 34...
  • Page 15: Automatic Update

    Manual mandatory updates are recommended when service calls occur for burner P003Bx LCDM. (1) Shut down and hold the forced update mode button (SW3) on the back of the writer. 5S-P-003-UM-EN-V007 – Oct. 14, 2022 © Copyright 2022, PADAUK Technology Co. Ltd Page 15 of 34...
  • Page 16 (3) Execute the writing application software and force the update of the writer version contained in the application software. Click OK and the software will automatically Download and Verify. 5S-P-003-UM-EN-V007 – Oct. 14, 2022 © Copyright 2022, PADAUK Technology Co. Ltd Page 16 of 34...
  • Page 17: Jumper Description

    Note: As for non-standard and unusual IC package, need be connected to JP7 through Connecting Board. Please refer to『Connecting Board Making』to learn about Connecting Board. 5S-P-003-UM-EN-V007 – Oct. 14, 2022 © Copyright 2022, PADAUK Technology Co. Ltd Page 17 of 34...
  • Page 18: Connecting Board Making Description

    IC is corresponding to the blank space Shift number need to shift from the top of SOCKET. Bit2:Write on board Option Option Description Bit4:VDD/VPP swap Others:Reserved 5S-P-003-UM-EN-V007 – Oct. 14, 2022 © Copyright 2022, PADAUK Technology Co. Ltd Page 18 of 34...
  • Page 19: Connecting Board Making

    IC is aligned with the upper left first pin of the Socket.) and connect the last 8 pins of Connecting Board with the corresponding pin of IC, as shown in the following figure: 5S-P-003-UM-EN-V007 – Oct. 14, 2022 © Copyright 2022, PADAUK Technology Co. Ltd Page 19 of 34...
  • Page 20: Case 1

    IC first pin align to the upper left fifth Shift shifted pin of Socket Bit2:Write on board Option Option Description Bit4:VDD/VPP swap 0x04 Others:Reserved 5S-P-003-UM-EN-V007 – Oct. 14, 2022 © Copyright 2022, PADAUK Technology Co. Ltd Page 20 of 34...
  • Page 21 NOTICE: If the thirteenth group number (shift) is changed to 0, it means that the first pin of IC aligns the upper left first pin of Socket, at the same time all connection of corresponding IC pins have to be changed. 5S-P-003-UM-EN-V007 – Oct. 14, 2022 © Copyright 2022, PADAUK Technology Co. Ltd Page 21 of 34...
  • Page 22: Case 2 (Customized Package Pin)

    The first pin of IC aligns the Shift be shifted upper left first pin of Socket Bit2:Write on board 0x04 Option Option Description Bit4:VDD/VPP swap Others:Reserved 5S-P-003-UM-EN-V007 – Oct. 14, 2022 © Copyright 2022, PADAUK Technology Co. Ltd Page 22 of 34...
  • Page 23 TA16 (PA3) ----------TB6(IC-PA3) TA17 (PA4) ----------TB7(IC-PA4) TA18 (PA5) ----------TA6(IC-PA5) TA19 (GND) ----------TB0(IC-GND) TB16 (PA0) ----------TB4(IC-PA0) TB17 (PA7) ----------TA6(IC-PA7) TB18 (PA6) ----------TA7(IC-PA6) TB19 (VDD) ----------TA5(IC-VDD) 5S-P-003-UM-EN-V007 – Oct. 14, 2022 © Copyright 2022, PADAUK Technology Co. Ltd Page 23 of 34...
  • Page 24: The Way To Add Package Pin Information To Pdk File

    Choose 『To Package』 Insert the information of package pin, please refer to section 5.1 for format. Click on 『OK』 Confirm again. Save as a new file. 5S-P-003-UM-EN-V007 – Oct. 14, 2022 © Copyright 2022, PADAUK Technology Co. Ltd Page 24 of 34...
  • Page 25: The Description Of Package Setting Details

    5S-P-003 Program Writer 5.6. The description of package setting details 5S-P-003-UM-EN-V007 – Oct. 14, 2022 © Copyright 2022, PADAUK Technology Co. Ltd Page 25 of 34...
  • Page 26: Semi-Automatic Writing Handler Connection Description

    OUTPUT / High Active written failed START INPUT / Low Active Semi-automatic Writing Handler send information to PROGRAM Active time >200ms notify Writer start to write. 5S-P-003-UM-EN-V007 – Oct. 14, 2022 © Copyright 2022, PADAUK Technology Co. Ltd Page 26 of 34...
  • Page 27 5S-P-003 Program Writer External picture Internal picture 5S-P-003-UM-EN-V007 – Oct. 14, 2022 © Copyright 2022, PADAUK Technology Co. Ltd Page 27 of 34...
  • Page 28: Set O/S Test And Blank Check

    7. Set O/S Test and Blank Check This chapter explains how to set writer which only do chips’ O / S test or blank check. Steps as follows: 5S-P-003-UM-EN-V007 – Oct. 14, 2022 © Copyright 2022, PADAUK Technology Co. Ltd Page 28 of 34...
  • Page 29 After complete the above steps, users can cooperate with semi-automatic equipment just do chips’ O/S tests or blank checks. NOTICE: Blank Check including O/S test. 5S-P-003-UM-EN-V007 – Oct. 14, 2022 © Copyright 2022, PADAUK Technology Co. Ltd Page 29 of 34...
  • Page 30: Writer Lcm Information And Buzzer Sound Table

    Invalid IC correction value Please replace IC Loss IC pkg info Invalid packing definition Please check the package definition in the source code 5S-P-003-UM-EN-V007 – Oct. 14, 2022 © Copyright 2022, PADAUK Technology Co. Ltd Page 30 of 34...
  • Page 31 Press and hold the writing button 5 consecutive short beeps Check whether the burning button continuously but not release it every 5 seconds is stuck 5S-P-003-UM-EN-V007 – Oct. 14, 2022 © Copyright 2022, PADAUK Technology Co. Ltd Page 31 of 34...
  • Page 32: Appendix Descriptions

    5S-P-003 Program Writer 9. Appendix Descriptions 9.1 The difference between 5S-P-003 and 3S-P-002 Project 5S-P-003 3S-P-002 Notes All pin do O/S test support nonsupport Writing time acceleration note1 PDK loading time acceleration note1 Jumper naming CNxx note2 support nonsupport LCM prompts jumper / IC position Phase out IC(ex: P232/P234)...
  • Page 33 『On-board Program』on the writer interface The ticking steps of MTP On-board VDD limitation: (1) Click on『Convert PDK』 (2) Click on『To Package』 (3) Click on『MTP On-board VDD limitation』 5S-P-003-UM-EN-V007 – Oct. 14, 2022 © Copyright 2022, PADAUK Technology Co. Ltd Page 33 of 34...
  • Page 34 If you have On-board writing or Multi-Chip (ex: MOS, EEPROM, and 2.4G), be sure to pay attention to above notification. Please follow the instruction in Section 9.2, especial for MTP voltage limitation. 5S-P-003-UM-EN-V007 – Oct. 14, 2022 © Copyright 2022, PADAUK Technology Co. Ltd Page 34 of 34...

Table of Contents