KOTLOSPAW SlimKo Plus Operation And Maintenance Documentation

KOTLOSPAW SlimKo Plus Operation And Maintenance Documentation

Table of Contents

Advertisement

Quick Links

1
KOTŁOSPAW Sp. z o.o.
UL. SZENICA 38, 63-300 PLESZEW
phone numer 600-494-315
handlowy@kotlospaw.pl
OPERATION AND MAINTENANCE DOCUMENTATION
Operation and assembly instructions
„SlimKo Plus" ......... kW
Serial no. ................
Year of production ................
ORIGINAL
Issue I
January 2022

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SlimKo Plus and is the answer not in the manual?

Questions and answers

Summary of Contents for KOTLOSPAW SlimKo Plus

  • Page 1 KOTŁOSPAW Sp. z o.o. UL. SZENICA 38, 63-300 PLESZEW phone numer 600-494-315 handlowy@kotlospaw.pl OPERATION AND MAINTENANCE DOCUMENTATION Operation and assembly instructions „SlimKo Plus” ……... kW Serial no. ……………. Year of production ……………. ORIGINAL Issue I January 2022...
  • Page 2 Before installing and using the boiler, please read this documentation carefully. WARNING: In case of any doubts or other suggestions regarding the information in this manual, please contact us at handlowy@kotlospaw.pl Always install and operate the boiler in accordance with applicable regulations and standards...
  • Page 3: Table Of Contents

    TABLE OF CONTENT 1.INTRODUCTION .................................. 5 1.1. General information ..............................5 1.2. General terms of use and warranty conditions ....................... 6 1.3.Delivery specification ..............................7 1.4.Transport of the boiler ..............................7 2. DESCRIPTION AND PURPOSE ............................8 3. TECHNICAL AND OPERATING FEATURES ......................... 8 4.
  • Page 4 10. RETURN PROTECTION OF THE BOILER ........................ 42 11. TECHNICAL AND OPERATIONAL DATA ........................42 12. COMMISSIONING ................................46 12.1. Pre-testing ................................47 12.2 Firing up ..................................47 12.3 Fuel refilling................................47 13. POWER ADJUSTMENT ..............................48 14. BASIC CONDITIONS FOR SAFE OPERATION ......................48 15.
  • Page 5: Introduction

    The Operation and Maintenance Documentation is a manual for solid fuel boilers with automatic fuel feeding for users of central heating water boilers with a SlimKo Plus-type pellet burner. Familiarizing yourself with the Operation and Maintenance Documentation, which contains information about the design, installation, and use of boilers is necessary for their proper and safe operation.
  • Page 6: General Terms Of Use And Warranty Conditions

    1.2. General terms of use and warranty conditions SlimKo Plus boilers are designed for installation in closed rooms - boiler rooms. The use of boilers for other purposes and ways of use not in accordance with the Operation and Maintenance Documentation is not allowed.
  • Page 7: Delivery Specification

    - protection in the open-loop system of the boiler not compliant with PN-91/B-02413 - protection in the closed-loop system of the boiler not compliant with PN-EN 12828 - use of a non-compliant chimney, - failure to perform cleaning and maintenance works on the boiler, - mechanical damage, - improper boiler room ventilation - failure to perform annual boiler inspections by the factory service.
  • Page 8: Description And Purpose

    2. DESCRIPTION AND PURPOSE SlimKo Plus type central heating water boilers for solid fuels equipped with a pellet burner and a high- class system of automatic regulation and control of the combustion process. They are intended for central heating systems in various types of facilities and domestic hot water production. They have been designed and manufactured as boilers with the low heat output and are intended mainly for small buildings and single-family houses.
  • Page 9: Types Of Fuel

    "warm" floors) 5. TYPES OF FUEL The basic fuel used in SlimKo Plus boilers is a pellet. After each change or delivery of fuel, it is absolutely necessary to carry out the so-called "FEEDER TEST" (for more details see feeder manual) It has a significant impact on the proper and trouble-free operation of the device.
  • Page 10 The body has a box design and is made in a bent-welded version, which reduces the number of welded joints that affect the tightness of the product. It consists of a furnace with an ash pan and a convection part and is additionally equipped with a door, a flue, nozzles, and an ash drawer. The furnace and ash pan constitute one chamber in which a burner with a spiral fuel feeder is located, together with a drive and a fan.
  • Page 11 WARNING! It is not allowed to open the furnace door when the boiler is working. The limit switch, which interrupts the boiler work after opening the furnace door, was installed for this purpose. Clean-out hatch The clean-out hatch is located on the back of the boiler in the area of the reversing (settling) chamber. The clean-out hatch with a partition works as a flue gas swirler.
  • Page 12 installing the boiler, are leading it to the right place. This connection is protected by a front cover that masks the electrical components of the boiler and protects the bin from sliding against the body. The bin has a fuel level view window. Keep the right fuel level of at least 1/4 of the bin's capacity Microprocessor controller The microprocessor controller is mounted in the front in the housing of the boiler.
  • Page 13: Pellet Feeder Assembly

    6.1. Assembly of the pellet feeder. a) view of the bin with cover b) view of the bin without front cover RURA SPIRO- SPIRAL PIPE, PODAJNIK – FEEDER, OSŁONA PRZEDNIA – FRONT COVER, USZCZELKA – SEAL – MOCOWANIE - MOUNTING...
  • Page 14: Types Of Boiler Safety Features

    6.2. Types of boiler safety features The controller is equipped with emergency sensors and shuts down the boiler and signals emergencies with light or sound signals on the desktop in the event of: - exceeding the max. water temperature in the boiler, - lack of fuel shuts down the entire system and extinguishes the burner, - reversion of flame/ember makes it impossible to feed fuel to the burner The STB thermal protection is a water temperature limiter, which is making sure that the water...
  • Page 15: Connecting Boiler To Heating System

    SlimKo Plus boilers should be installed in accordance with the Operation and Maintenance Documentation of the boiler, boiler room design, requirements for ventilation and flue gas discharge, and the quality of boiler feed water.
  • Page 16: Flue Installation

    Choosing a chimney system solution Modern SlimKo Plus devices from Kotłospaw, due to their high efficiency, have a very low flue gas temperature and require chimney systems capable of operating in wet mode, which are characterized by low water absorption.
  • Page 17 If an existing chimney is used, it must be protected against the destructive effects of condensate with a steel insert. It should be checked if the cross-section of the existing chimney allows the installation of an insert with an appropriate diameter to guarantee the proper functioning of the SlimKo Plus boiler.
  • Page 18 In case of a chimney system deviating from the indicated parameters, calculations should be made according to PN-EN 13384-1 Height of vertical Height of vertical part Height of vertical part part 8 linear meters 10 linear meters 12 linear meters Boiler 12 kW 160mm...
  • Page 19 Pokrycie non-flammable or difficult to set on fire, the outlets should be at least 0.3m higher than the roof surface and at least 1.0m away measured horizontally from this surface Pokrycie niepalne, >1m niezapalne lub trudnozapalne c) p location of the chimney next to the element of building which will be an obstacle (shield/cover) for the proper operation of the ducts, their outlets should be additionally above the surface led out at an angle of 12 degrees down from the level of the highest obstacle (cover) for chimneys located at a distance of 3 to 10m from this obstacle...
  • Page 20 Vertical flue system The duct routing should be vertical. A deflection from the vertical direction of not more than 30 degrees is allowed. Provided the inspection holes with a tight door are installed the duct deflections, it is allowed to deflect the duct by up to 45 degrees from the vertical direction, the length of the duct in the direction deflected from the vertical should not exceed 2m Equipmment of the vertical flue system The duct must be equipped with an inspection hole with a tight door, and a condensate...
  • Page 21: Central Heating System

    angle and above must have inspection holes. The flue should be routed with a slope towards the boiler. Directly in front of the boiler, an element should be installed to drain the condensate appearing in the flue part. The condensate cannot get into the boiler Fire safety Flue ducts should be made of non-flammable materials.
  • Page 22: Protection Of Boiler In An Open-Loop System

    - connect the control device and check the electrical installation 7.4. Protection of boiler in an open-loop system The most important requirements for a SlimKo Plus type boiler protected in an open-loop system with an expansion vessel: - an open-loop system expansion vessel with a capacity calculated in accordance with 2.5.1 PN-...
  • Page 23 Size of pipes protecting the boiler in open-loop system according to PN-91/B-02413 Thermal power of the boiler [hW] Safety pipe [mm] Expansion pipe [mm] Ø nominal Ø internal Ø nominal Ø internal from 27,5 27,2 35,9 41,8 Figure 1a...
  • Page 24 Location of the expansion vessel above the highest point of the water circulation according to PN-91/B-02413 The L and H distances are given as standard...
  • Page 25: Protection Of Boiler In A Closed-Loop System

    PN-91/B-02413 7.5. Protection of boiler in a closed-loop system The most important requirements for SlimKo Plus boilers protected in a closed-loop system with an expansion vessel. In accordance with applicable regulations, SlimKo Plus-type boilers meet the requirements of EU directives at the design and production stage.
  • Page 26: Assembly Requirements

    Its task is to directly supply cold water to the boiler water system and the simultaneous outflow of hot water from the boiler. The water flow through the cooled boiler should be correctly chosen according to the cooling parameters in Table 3. It cannot be too low, but it cannot be too intense. The cooling valve is an integrated connection between reducing, filling, and discharge valves.
  • Page 27: Safety Requirements

    Front view of the boiler without the bin Rear view of the boiler without the bin thermal protection sensor coupling SYR 5067 1x1/2” female-thread, automatic vent coupling 1x1/2” female-thread, thermal protection sensor coupling SYR 5067 1x1/2” female thread, supply couplings 2x1” female-thread, automating vent coupling 1x1/2”...
  • Page 28 WARNING! Connecting to a hydrophore water intake is not recommended. Table no. 3 List of thermo-technical parameters of cooling valves for SlimKo Plus boilers Boiler power [kW] [m³/h] Cooling water stream...
  • Page 29: Installation Scheme

    [°C/min] Boiler water cooling speed 7.5.7. Installation scheme Scheme and description of the installation of equipment for protection in a closed-loop system is shown in Fig. 2, Fig 2. Installation scheme of the boiler in a closed-loop system protected by a cooling valve. ZS- cooling valve ZB –...
  • Page 30: Requirements For Closed-Loop System Operation

    ZN- filling valve NP- expansion vessel ZU- discharge valve PO – circulation pump ZO – cutoff valve CT- temperature sensor 7.5.8. Requirements for closed-loop system operation Before commissioning, the manufacturer's or trained installer's service must check if all devices and equipment in a closed-loop system with an expansion vessel are working as they should.
  • Page 31 exceeding θmax. This maximum temperature in a central heating system that occurs during a failure should be used to calculate the size of the vessel; c) Initial designed pressure in the system. Initial designed system pressure, pO, should be at least the sum of static pressure, pST, and steam pressure, pD: p0 ≥...
  • Page 32 NW-P Figure D.1 – Recommended location of the expansion vessel in the central heating system ZC – Heat source, PO – Circulation pump, OG – heating circuit, ZB -Safety valve NW-P - Recommended place for connecting an expansion vessel...
  • Page 33: Calculating The Size Of The Expansion Vessel

    7.5.10. Calculating the size of the expansion vessel The exact size of the expansion vessel can be calculated in a following way: a) Determine - water capacity of the system, in liters. It is the total capacity of ducts, radiators, heat sources system and auxiliary circuits maximum...
  • Page 34 ∙ (p + 1) exp min ≥ --------------------- - 1 a min exp min where is the capacity of the chosen expansion vessel in liters. exp min d) To protect against exceeding the final pressure at maximum temperature, taking into account , pe, the exceeded designed temperature, the initial pressure (pressure of filling the system) should...
  • Page 35 Table D.2 – relative volume increase, , in relation to the maximum temperature, taking into account the exceeded design temperature (filling temperature 10°C - design temperature water volume 4°C) Maximal temperature including room Relative volume increase temperature °C 0,66 0,93 1,29 1,71 2,22...
  • Page 36 1. Boiler in a closed-loop system with a 4-way mixing valve 2. Boiler in an open-loop system with a 4-way mixing valve 3. Boiler in a closed-loop system with a temperature valve ATV 55*...
  • Page 37 4. Boiler in an open-loop system with a temperature valve ATV 55* 5. Boiler in a closed-loop system with a hydraulic coupler...
  • Page 38 6. Boiler in a closed-loop system with a heat buffer Kocioł = boiler; Pompa kotłowa = Boiler pump; Zawór temperaturowy = temperaturę valve; Zawór trójdrogowy = 3-way valve; Siłownik zaworu 3D = Valve actuator 3D; Pompa ładowania zasobnika CWU = DHW bin feedning pump; Regulator temperatury = Temperature controller; Ogrzewanie podłogowe = Floor heating;...
  • Page 39: Wiring

    Czujnik temperatury zasobnika CWU = DHW tank temperature sensor; Grupa bezpieczeństwa CWU = DHW safety unit; Naczynia przeponowe CWU = DHW expansion vessel; Bufor = buffer WARNING! The above hydraulic diagrams do not replace central heating system designs and are for preview purposes only! 8.
  • Page 40 UWAGA! It is recommended that a separate circuit of the electrical system be installed to supply the boiler.. NO. ON THE FUNCTION DESCRIPTION CONTROLLER 1 / 2 STB temperature protection 3 / 4 External feeder 5 / 6 Burner blower fan and internal feeder (hybrid drive)) 7 / 8 Exhaust fan 8 / 9...
  • Page 41 Dedicated room regulator Fan fuse Fan fuse of the external feeder...
  • Page 42: Filling With Water

    9. FILLING WITH WATER Before starting a fire in the boiler, fill the heating system and the boiler with water. The filling should be carried out in accordance with the instructions of the installer. To check whether the installation has been filled correctly, unscrew the valve on the signaling pipe for several seconds - the continuous flow of water from the signaling pipe means that the water fills the expansion vessel located at the highest point of the system, not just the signaling pipe.
  • Page 43 The basic data of the SlimKo Plus boiler series in terms of technical and operational parameters are specified in Table No. 4. Figure 4 describes the individual parts of the boiler. The dimensions of the SlimKo boilers showed in Figure 5 are specified in Table 5.
  • Page 44 Table 4. Type of boiler: SlimKo Plus 12/3b 16/3b 20/3b 24/3b 30/3b Boiler power Power range 3,6-12 4,8-16 6-20 7,5-25 9-30 Efficiency at nominal power 93,3 92,1 92,1 92,5 Boiler class according to PN EN-303- 5:2021 Bin capacity Weight of the set w/o water Approx.
  • Page 45 (applies to boiler version with designation /3b) °C 10÷25 Requirements for Cold water temp. water supplying heat exchanger Water pressure 1,71) or 2,72) thermal protection (see the SYR 5067 thermal protection manual) °C Exhaust gas nominal temperature at lowest power Flue gas mass flow nominal kg/s...
  • Page 46: Commissioning

    ø COMMISSIONING OF THE BOILER Before the first commissioning and every subsequent start-up of the SlimKo Plus boiler, check if it is correctly connected to the central heating, flue, electrical, and ventilation system. Particular attention should be paid to protecting the installation in an open-loop system according to PN 91/B-02413 or closed-loop PN-EN 12828 and whether the heating system is correctly filled with water, and whether the water in the system and the boiler is not frozen.
  • Page 47: Pre-Testing

    WARNING! When firing up a cold boiler, condensation may occur on the boiler walls, so-called sweating, giving the illusion that the boiler is leaking. This is a natural phenomenon that disappears after the boiler warms 12.1. Pre-testing Before initial commissioning check the following: - connection of the bin with the boiler - whether the ash drawer is mounted correctly - covers of drive mechanism...
  • Page 48: Power Adjustment

    13. POWER ADJUSTMENT In order to adjust the power, the SlimKo Plus boiler is equipped with a microprocessor-based temperature controller, which allows, depending on the needs, operation with appropriate performance. The regulator has a boiler power modulation mechanism - allowing it to gradually reduce its power as the boiler temperature is reaching the set value.
  • Page 49: Disturbances In The Operation Of The Boiler. Frequently Occurring Problems And

    formation of condensate (greasy liquid) and causing intensive boiler corrosion WARNING! Poor fuel quality, low calorific value, high moisture, and ash content, and non-flammable compounds - cause rapid contamination of the burner with slag, ash, hinders and prevents the possibility of the proper combustion process.
  • Page 50 • perform feeder test, • incorrect fuel feeding time check and verify controller and break settings settings • adjust the fan power with Fuel does not burn completely • incorrect amount of air for the use of the shutter or combustion set settings on the controller...
  • Page 51: Cleaning And Maintenance

    • set the boiler operating •the boiler is ‘’sweating” temperature above 50°C Water leaking from the boiler on the return • leakage of the water part • notify the manufacturer's of the boiler body service department • it is recommended to •...
  • Page 52: Fire Safety

    deposits should be removed outside the boiler through the open door and cleaning hatch of the reversing chamber WARNING! After cleaning the boiler, close all doors and cleaning hatches covers and check if they are tight. Remember about the ash drawer. It is also important to periodically clean the burner and the feeder, the and controller of the boiler, preventing dust and ash from accumulating on these elements, and carry out inspection and maintenance according to their operating instructions (Operation and Maintenance Documentation).
  • Page 53: Shutting Down The Boiler

    EMERGENCY STOP The boiler operation is automatic with the option of switching the boiler off and extinguishing it in emergency situations specified in the burner and controller manual. In case of other hazards to the further operation of the boiler and emergency conditions, as well as failure to shut down and extinguish the boiler, such as an uncontrolled increase in boiler water temperature and pressure, a sudden large leakage of water in the boiler or system, damage to the control system, fittings and boiler equipment and system:...
  • Page 54: Environmental Protection

    The boiler manufacturer is not responsible for the technical condition and execution of the central heating system. Due to the constant technological progress, the manufacturer may introduce structural changes to the boilers on an ongoing basis, improving their operation and emission parameters. Any design changes must, however, be confirmed by a research process completed with appropriate documentation.
  • Page 55: Causes Of Residual Risk And How To Eliminate It

    practice. In order to draw the user's and operator's attention, the boiler has been marked with appropriate symbols, signs, notes in the Operation and Maintenance Documentation about the risk of unauthorized use - which the user must strictly observe. 22.1. Causes of residual risk and how to eliminate it Residual risk exists in the event of non-compliance with the specified recommendations and instructions stated in the manuals of the boiler and its equipment.
  • Page 56: Conditions To Be Met For Safe Operation Of The Boiler

    - extreme caution and attention when loading pellets into the fuel container 23. CONDITIONS TO BE MET FOR SAFE OPERATION OF THE BOILER The basic condition for the safe operation of boilers is the correct installation in accordance with the regulations in force and applicable standards.
  • Page 57 02413 and Operation and Maintenance Manual Properly insulate the central Water freezing in the boiler and Boiler damage, explosion heating system and an central heating system. expansion vessel Storage of flammable and Removal of all flammable explosive materials such as Fire, explosion substances and material near solvents, paints, etc.
  • Page 58 A possible final and tragic result of the above-mentioned risks resulting from improper use of the boiler may be burns, poisoning, disability and in extreme cases even death...
  • Page 59: Ecodesign Info Card

    0,0117 [30%/50%] of rated heat output secondary equipment for [x,xxx/N.A.] emission reduction, if applicable in standby mode 0,0030 KOTŁOSPAW Sp. z o.o. Contact details ul. Szenica 38, 63-300 Pleszew tel. +48 62 597 14 78 e-mail: kotlospaw@kotlospaw.pl...
  • Page 60 0,0123 [30%/50%] of rated heat output secondary equipment for [x,xxx/N.A.] emission reduction, if applicable in standby mode 0,0030 KOTŁOSPAW Sp. z o.o. Contact details ul. Szenica 38, 63-300 Pleszew tel. +48 62 597 14 78 e-mail: kotlospaw@kotlospaw.pl...
  • Page 61 0,0129 [30%/50%] of rated heat output secondary equipment for [x,xxx/N.A.] emission reduction, if applicable in standby mode 0,0030 KOTŁOSPAW Sp. z o.o. Contact details ul. Szenica 38, 63-300 Pleszew tel. +48 62 597 14 78 e-mail: kotlospaw@kotlospaw.pl...
  • Page 62 0,0146 [30%/50%] of rated heat output secondary equipment for [x,xxx/N.A.] emission reduction, if applicable in standby mode 0,0030 KOTŁOSPAW Sp. z o.o. Contact details ul. Szenica 38, 63-300 Pleszew tel. +48 62 597 14 78 e-mail: kotlospaw@kotlospaw.pl...
  • Page 63 0,0162 [30%/50%] of rated heat output secondary equipment for [x,xxx/N.A.] emission reduction, if applicable in stnadby mode 0,0030 KOTŁOSPAW Sp. z o.o. Contact details ul. Szenica 38, 63-300 Pleszew tel. +48 62 597 14 78 e-mail: kotlospaw@kotlospaw.pl...
  • Page 64: Product Sheet

    25. PRODUCT SHEET Product sheet in accordance with the EU Regulation 2015/1187 supplementing Directive 2009/125 of the European Parliament and Council.. Manufacturer Device parameters Model ID Energy efficiency class Rated thermal power Energy efficiency ratio Seasonal heating energy efficiency Observe all assembly, installation and maintenance requirements in the operating instructions supplied with the boiler.
  • Page 66 Notes __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________...
  • Page 67: Warranty Conditions

    26. WARRANTY CONDITIONS 1. The warranty constitutes a commitment of the manufacturer of the boiler for a free removal of physical defects during its duration resulting from manufacturing defects. 2. Independent devices such as regulator and burner have their own warranty cards and specified warranty conditions.
  • Page 68: Warranty Period

    - - boiler exchanger, if the device has - boiler temperature sensor - sockets been registered on the - flame sensor - plugs kotlospaw.pl/przedłużanie-gwarancji - STB protection - other galvanized steel elements website and boiler return - gears - stainless and acid-resistant steel temperature protection for min.
  • Page 69 Documentation of the boiler, burner and controller, - has a boiler return temperature protection for min. 50*C, - has been registered within 30 days from the date of installation at: www.kotlospaw.pl/przedluzanie-gwarancji , - paid boiler commissioning and paid annual inspections were performed by the Kotłospaw Service,...
  • Page 70 CONFIRMATION OF INSTALLATION AND PROTECTION OF THE BOILER according to PN-91/B-02413 (open-loop) Type of boiler: SlimKo Plus…………kW Serial No.: ……………………... Year of production: ………………………. INSTALLER: Name of the company:……………………………………………………………………….. Address/phone number …………...………………………………………………………….. USER: First and last name:…………………………………………………………………….. Address/phone number:……………………………………………………………………….. ……………………………………………………………………………………….
  • Page 71 …………………………….. Date, signature and stamp of the installer...
  • Page 72 CONFIRMATION OF INSTALLATION AND PROTECTION OF THE BOILER according to PN-EN 12828:2003 (closed-loop) Type of boiler: SlimKo Plus…………kW Serial No.: ……………………... Year of production: ………………………. INSTALLER: Name of the company:……………………………………………………………………….. Address/phone number …………...………………………………………………………….. USER: First and last name:…………………………………………………………………….. Address/phone number:………………………………………………………………………..
  • Page 73 Person authorized to issue technical documentation: Przemysław Wroński By signing this document, we declare with full liability that the central heating water boiler for solid fuels with automatic pellet feeding, low-temperature type: SlimKo Plus protected in an open-loop or closed-loop system manufactured by our company.
  • Page 74 WUDT/UC/2003 Pressure devices The boilers have a certificate of compliance with the requirements of the 5th class of emission limit values according to PN-EN 303-5: 2021 and ecodesign. Certificates no.: - 5th class 12kW – 19.34033/21-1/7 16 kW – 19.34033/21-1/7 - 5th class 20 kW –...
  • Page 75: Warranty Card

    28. WARRANTY CARDS Name of the central heating boiler: Steel water boiler with an automatic pellet burner Type: SlimKo Plus Power …..[kW] Serial number ....The warranty is valid from the date of purchase on Boiler 24 months boiler with return protection *...
  • Page 76 BOILER COMMISSIONING AND INSPECTION PROTOCOL Model and power of the User’s firs and last name boiler Serial number of the Phone number boiler Year of production Address Serial number of the burner INSTALLER SERVICE TECHNICIAN Phone number Phone number Company stamp Company stamp Check list Data...
  • Page 77 Notes __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________...
  • Page 78 SERVICE VISIT PROTOCOL The protocol is completed by the authorized service of KOTŁOSPAW Sp. z o.o. The report must be completed in the presence of the boiler user, who is obliged to provide the service technician with the documentation for the boiler, the boiler room and all elements of the central heating system in the building. Failure to agree to the above requirements will result in loss of warranty for the boiler, carburizing system with a blower and microprocessor, or a pellet burner with accessories..
  • Page 79 SERVICE VISIT PROTOCOL The protocol is completed by the authorized service of KOTŁOSPAW Sp. z o.o. The report must be completed in the presence of the boiler user, who is obliged to provide the service technician with the documentation for the boiler, the boiler room and all elements of the central heating system in the building. Failure to agree to the above requirements will result in loss of warranty for the boiler, carburizing system with a blower and microprocessor, or a pellet burner with accessories.
  • Page 80 KOTŁOSPAW Sp. z o.o. UL. SZENICA 38, 63-300 PLESZEW Service department: 512-373-826 serwis@kotlospaw.pl Sales department: 600-494-315 handlowy@kotlospaw.pl...