Sterling Sterilisers Acuatic Vacuum 12 B User Instructions...
Page 2
Please take time to read these instructions before using the steriliser for the first time, then keep them in a safe convenient place for future reference. After Sales Service Sterling Sterilisers staff are available to provide verbal advice and assistance by phone during normal office hours and to answer written queries by post or email. For further information visit www.sterlingsterilisers.com...
Acuatic Vacuum steriliser Thank you for choosing the Acuatic Vacuum 12 B steriliser from Sterling Sterilisers. We are confident that you have purchased the finest steriliser of its type which will provide you with many years of efficient, reliable service.
Illustration Acuatic Vacuum steriliser door seal chamber with tray rack and trays water filling spout touch screen display clean water drain used water drain data logger Cycle Charts Pressure/time graphs are shown below for both N-type and B-type cycles. Sterilising Sterilising 138°C 138°C...
Safety Acuatic Vacuum steriliser General Safety Read these User Instructions carefully before using your steriliser and keep them for future reference. There are no user serviceable parts internally. Never remove the steriliser casing or try to insert objects through holes or openings. The steriliser is heavy - 23 kg.
Care and Data Logger Acuatic Vacuum steriliser Daily Maintenance Clean the door seal using a lint free cloth and soapy water. Check the door seal for any signs of damage and replace if necessary. Clean the face of the chamber that the door seal closes onto. Only use chlorine free Drain both reservoirs at the end of each day and leave empty overnight.
Getting Started Acuatic Vacuum steriliser Getting Started Place the steriliser on a flat, level, strong, heat resistant and water resistant surface. Ensure a clearance of 50 mm to the top and both sides of the steriliser for adequate ventilation. Ensure that nothing that can be affected by heat is above or behind the steriliser. Plug into the mains.
RESET RESET Contact your local service engineer or Sterling Sterilisers Ltd in the event of any fault occurring. Please provide as much information as possible with regard to the problem including the number and description of any error message displayed.
Securilog Data Logger Acuatic Vacuum steriliser Securilog Data Logger The inbuilt Securilog data logger securely records encrypted cycle data onto a memory card. The cycle data can be copied to and read from a computer once the Securilog application has been installed to that computer. To record cycle data ensure that an SD memory card formatted with the FAT16 file system Do not remove power or take the SD memory...
4. A Product Registration and Customer Survey form. Please take the time to print this out, complete it and return it to Sterling Sterilisers so that we can keep our records up to date and use your feedback to further develop our product to better suit future needs.
Page 12
Feature Dimensions Width 425 mm Height 340 mm Length 500 mm Weight 23 kg Chamber diameter 218 mm Chamber length 320 mm Chamber volume 12 litres Trays Number Width 183 mm Length 284 mm Maximum loading per tray 1.5 kg Clearances Top and sides 50 mm...