WIRING DIAGRAM WITH ACTIVE SYSTEM PHASE
AND GENERIC ALARM.
The unit is set up for the management of any external pump;
the pump is powered in concomitance with the request phase
on the system.
All the relays can be configured as an active system phase; the
diagram represents the connection on relay 2. In the event this
relay is used, it is necessary to jump pins 57 and 58 of connector
X25 positioned on the relay board.
Legenda:
A3 - Integrated P.C.B.
A7 - Three relay board
K1 - Configurable relay
K2 - Configurable relay
K3 - Configurable relay
M10-1 - Zone 1 pump
Fig. 4-2
WIRING DIAGRAM WITH PUFFER MODE ACTIVE.
The device is set up for the management of any pre-heated puffer.
During a request for heating, in case the heating probe detects
a temperature higher than the one requested, the system circu-
lating pump is activated while the generator is kept off.
Fig. 4-3
In addition, the possible connection to relay 1 is represented.
The device is set up for the management of any generic alarms.
All the relays can also be configured as generic alarm. The ''ge-
neric alarm'' signal is enabled whenever one of the envisioned
anomalies occurs in the device (see device book under ''Trou-
bleshooting'').
All the relays can be configured as an active system phase; the
diagram represents the connection on relay 2. In the event this
relay is used, it is necessary to jump pins 57 and 58 of connector
X25 positioned on the relay board.
46
Legenda:
A3 - Integrated P.C.B.
A7 - Three relay board
B13 - Heating probe
K1 - Configurable relay
K2 - Configurable relay
K3 - Configurable relay
M10 - Buffer pump
M10-1 - Zone 1 pump