AVO MEGGER FlexiClamp 200 User Manual

AVO MEGGER FlexiClamp 200 User Manual

Advertisement

Archcliffe Road
Dover
Kent CT17 9EN
England
510 Township Line Road
Blue Bell
PA 19422-2795
U.S.A.
4651 S. Westmoreland Road
Dallas
TX 75237-1017
U.S.A.
MEGGERSA
29, Allée de Villemomble
93340 Le Raincy
Paris
France
New instruments are guaranteed for 1 year from the date of
Any unauthorized prior repair or adjustment will automatically invalidate
the Warranty.
For service requirements for MEGGER® Instruments contact :-
AVO INTERNATIONAL
Archcliffe Road
Dover
Kent, CT17 9EN
England
Tel: +44 (0) 1304 502243
Fax:+44 (0) 1304 207342
or an approved repair company.
This instrument is manufactured in the European Union.The Company
reserves the right to change the specification or design without prior
notice.
MEGGER is the registered Trade Mark of AVO INTERNATIONAL
LIMITED.
This data uses the comma as the decimal marker to align with general
European usage. Copyright © AVO INTERNATIONAL LIMITED.
Part No 6172-215 Edition 1 - 2CC
AVO INTERNATIONAL
Repair and Warranty
purchase by the User.
Instrument Repair and Spare Parts
Tel: +44 (0) 1304 502100
Fax:+44 (0) 1304 207342
Tel: +1 (215) 646-9200
Fax:+1 (215) 643-2670
Tel: +1 (800) 723-2861 (U.S.A.only)
Te l : +1 (214) 330-3203 (Intern a t i o n a l )
Fax:+1 (214) 337-3038
Tel: +33 (1) 43.02.37.54
Fax:+33 (1) 43.02.16.24
or
AVO INTERNATIONAL
510 Township Line Road
Blue Bell
PA 19422-2795
U.S.A.
Tel: +1 (215) 646-9200
Fax:+1 (215) 643-7215

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MEGGER FlexiClamp 200 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AVO MEGGER FlexiClamp 200

  • Page 1 This instrument is manufactured in the European Union.The Company reserves the right to change the specification or design without prior notice. MEGGER is the registered Trade Mark of AVO INTERNATIONAL LIMITED. This data uses the comma as the decimal marker to align with general European usage.
  • Page 2 ® MEGGER FlexiClamp 200 User Guide SAFETY WARNINGS • The section of wire under test must be clean, free of debris, and undamaged. • Measurements beyond maximum selected range must not be taken. • When taking measurements above 30 V RMS, extreme care must be taken, with the hand kept behind the hand guard.
  • Page 3 When measuring the current in a flat cable, the cable must be positioned as follows: The proximity of other current carrying conductors may affect the reading. Keeping a minimum distance of 125mm (5”) from these conductors will minimise this. Read the current directly from the display. The ‘Hold’ button holds the reading on all ranges.
  • Page 4 Specification Measuring Ranges: Single wire mode 0 to 199,9 Amp 2-or-3-wire mode 0 to 40,0 Amp Resolution: 0,1 Amp. Accuracy: At 22˚C (72˚F) and rated frequency Single wire 2% of reading ± 2 digits 2-or-3-wire mode Flat or Twin cable 5% of reading ±...