Flow-Rite Eagle Eye Elite IV Installation & Operation Instructions

Flow-Rite Eagle Eye Elite IV Installation & Operation Instructions

In-valve battery level sensor with pro-fill flex and rigid manifolds

Advertisement

Quick Links

Contents
(1) Deep cycle battery level sensor
(1) Mounting plate
(1) Instruction sheet
(2) Zip ties
1
Non-Main Batteries
Locate your main batteries (main positive and
main negative).
Probe must be installed in a non-main battery.
3
Snap the Eagle Eye sensor in the open space
on the flex manifold.
5
Secure the control box with a provided zip tie
in a secure location.
BL-642-0721
Eagle Eye Elite IV
In-Valve Battery Level Sensor with
Pro-Fill Flex and Rigid Manifolds
INSTALLATION &
OPERATION INSTRUCTIONS
for BG-C48V-11-EA-WS & BG-C48V-21-EA-WS
Tools Required
1/2˝ wrench
Rubber gloves
Safety glasses
1/2˝ drill bit (For remote use)
Main Neg
Main Pos
Specifications
Max current draw: 7mA
Nominal operating voltage: 12 - 48V
Operating temperature: -22°F - 158°F
2
Install the valves on the rigid manifolds by
inserting and twisting in to secure.
Note: Leave battery 4 open for flex manifold.
4
Sensor Valve
Insert flex manifold valves into battery 4 and
twist in to secure. Attach snake tubing to the
ends of the manifold.
6
Attach the red wire to the positive terminal of the
positive main battery. Connect the black wire to
the negative of the negative main battery.

Advertisement

loading

Summary of Contents for Flow-Rite Eagle Eye Elite IV

  • Page 1 Eagle Eye Elite IV In-Valve Battery Level Sensor with Pro-Fill Flex and Rigid Manifolds INSTALLATION & OPERATION INSTRUCTIONS for BG-C48V-11-EA-WS & BG-C48V-21-EA-WS Contents Tools Required Specifications (1) Deep cycle battery level sensor 1/2˝ wrench Max current draw: 7mA Rubber gloves...
  • Page 2 • This product is intended to monitor electrolyte levels inside of flooded lead acid batteries. Failure to use this product in the manner intended could compromise safety protection provided by the equipment. • Probe should be wiped clean and terminals checked for corrosion each time the battery has preventative maintenance. Flow-Rite Controls 960 74th St. Byron Center, MI 49315 phone: 616-583-1700 www.flow-rite.com...