Contents General Safety Warnings Personal Safety Machine Product Product Overview Functions and Features Operation and Use Installation Guide Wiring Connections Diagrams − External Wiring Diagram (300o) − ETR External Wiring Diagram (478i) Calibration Calibration (CAL) Mode No Extension Mode Service Information Service Schedule Service Procedure Parts List...
General Safety Warnings Personal Safety ■ Everyone is responsible for safety. ■ The installer/service personnel should be trained and authorized to complete the required work. ■ Ensure that the machine is safely isolated during installation and testing to protect all personnel. ■...
Product Overview The Muirhead ® Fire System Status panel, part number 5884, is a unique product that incorporates the following features: ® Figure 1 Muirhead Fire System Status panel, part number 5884 Function Description Cylinder Pressure The alert indicator is green when the cylinder pressure is correct, above Correct 1200 kPa.
Operation and Use The control unit does not operate while the ignition is not active. After ignition is applied, the unit pulses the alert indicators and alarm twice to show that they are operating. The control unit state is displayed by the alert indicators as follows: ■...
4 Orange Ignition supply via fire pressure switch. 5 Purple Operates opposite to ignition output. 1 A continuous. Sonar ground not supplied from 5884 fire panel. 6 Green Sonar positive. Not used in new 5884 fire panel. Not used in new 5884 fire panel.
L1-J7, 16/12/14 wiring from EPS and replaced 7650 with 5884, THE FIRE CONTROLLER RED WIRE CAN BE CONNECTED TO THE ORANGE WIRE OF THE PRESSURE SWITCH TERMINAL TO AVOID THE FIRE CONTROLLER TIMING OUT AFTER SIX (6) SECONDS WHEN THE IGNITION IS SWITCHED OFF.
No Extension Mode The 5884 can also be configured for no extension on shutdown. The process for setting this function is below. Press and hold the control unit panel test push button once in calibration mode for more than 10 seconds and then release it.
Turning the ignition on and off WILL NOT RESET the system. Parts List Part No. Description 5884 Fire system status panel 0475 Tank pressure switch low warning 1200 kPa (not supplied with unit) 2348...
Glossary Amp (Ampere) Minimum alternating current millimetres Advanced Management System Milliwatts Auxiliary Output Not Applicable Controller Area Network Normally Closed CMIO Control Master Input Output PCB Normally Open Control Master Receiver Original Equipment Manufacturer Control Master Transmitter Outputs CM2200 Control Master 2200 Remote Set Output COMMS Communications...
Revision History Date Details of change 01/07/2007 BT/DH Initial document draft and approval 04/07/2011 Updated drawing 300o. Updated Parts List 11/09/2013 Updated Operation and Use section 05/05/2014 Updated Installation Instructions section 06/01/2015 Updated Parts List section 25/09/2015 CamB Revised manual and updated to new format 12/10/2015 Updated terminology throughout: - Control unit replaced controller, panel, and fire unit...