Legend Safety instructions Printer Attention! When testing the battery, Key paper advance explosive gases can be created. Slide switch Only test batteries in well Battery tap to battery / at ventilated areas! external test point in engine Danger of explosion due to space formation of oxyhydrogen gas.
Device description You can test 12 V starter batteries from 80 - 499 A DIN resp. 95 - 574 A IEC resp. 136 - 855 A EN/SAE = cold cranking current using the battery tester. For test purposes, the batteries are loaded with a current which is equivalent to the starting current of a car or lorry.
"Starting capability very bad" – replace battery "Cannot be tested" - recharge battery and test again. LED (8) indicates whether the battery has been connected the wrong way round. • LED (9) indicates "battery cannot be tested, battery has to be charged". •...
Battery test - high current load Recognising battery guarantee damage: Manufacturing faults can be recognised using the testing device with a high current load on the battery. Typical guarantee cases are fine contacts and cold soldering points in the cells which do not occur until after the battery is being used.
Press key "paper feed " (2) until the paper has been pushed out by approx. 3 cm. Feed the paper through the slot in the cover and close the cover. Press the "Start" key (6). Green LED extinguishes. • Turn off switch (4). Remove clamps from battery.