Taking Out Of Operation At Short Notice; Possible Emergency Repairs - ABB HT614805 Original Operation Manual

Table of Contents

Advertisement

Operation Manual / TPS44-H.. - TPS52-H..
11 Taking out of operation at short notice / 11.1 Possible emergency
repairs
11

Taking out of operation at short notice

11.1

Possible emergency repairs

WARNING
Danger of fire and explosion due to lubricating oil leaks
Leaking oil may ignite on hot surfaces. This can result in serious injuries to
personnel or fatal accidents.
Cordon off danger area.
u
Raise the alarm and, depending on the situation, stop the engine.
u
Seal the oil leak.
u
Soak up oil and dispose of in an environmentally compatible manner.
u
Wear safety gloves to protect against thermal hazards.
CAUTION
Directives for taking out of operation
Serious damage to engine or property can be caused by non-compliance
with the directives for blanking the turbocharger off the engine.
Follow the directives of the enginebuilder.
u
To enable you to quickly put an engine back into operation after a turbocharger has sus-
tained damage, ABB Turbocharging recommends having a replacement turbocharger or ap-
propriate spare parts available in storage. The defective turbocharger can be removed and
the replacement turbocharger installed within a short period of time.
Remove defective turbocharger (see chapter
u
Install replacement turbocharger (see chapter
u
Send the defective turbocharger to an ABB Turbocharging Service Station for inspection
u
and repair.
© Copyright 2021 ABB. All rights reserved.
Removing and Installing
Removing and Installing
HZTL4037_EN
→28).
→28).
Rev.G
June 2021

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tps44-h31