Page 1
SIG7412 T MPEG2 Encoder Modulator User Manual Manuale d’uso Encoder...
Page 2
The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. Fracarro shall have no liability for any error or damage of any kind resulting from the use of this document.
Chapter 1 Introduction 1.1 Product Overview SIG7412 T MPEG2 12 in 1 encoder modulator is Fracarro’s newest devices which integrate MPEG2 encoding, multiplexing, and DVB-T modulation. It supports 12 CVBS input. It also support DVB-T RF out with 4 adjacent carries (50MHz~960MHz), and support Data1 (GE) output port to support 4 MPTS out.
Chinese and English language System function Ethernet software upgrade Dimension(W×L×H) 482mm×410mm×44mm Approx weight Environment 0~45℃(work);20~80℃(Storage) Miscellaneous Power requirements AC 110V± 10%, 50/60Hz, AC 220 ± 10%, 50/60Hz Power consumption SIG7412 T MPEG2 Product Name 287610 Product Code 1.4 Principle Chart pag6...
1.5 Appearance and Description Front and Rear Panel Illustration RF test and RF out port Port Power supply and Grounding Pole 12 CVBS input (Q9 to RCA) Reset Key/Data Port Indicator Indicator DATA Port (for IP stream input/output) pag7...
The product must only be installed by qualified persons, according to the local safety standards and regulations. Fracarro Radioindustrie is free from all civil and criminal responsibilities due to breaches of the current legislation derived from the improper use of the product by the installer, user or third parties.
Although the information given in this manual has been prepared carefully and thoughtfully, Fracarro Radioindustrie S.r.l. reserves the right to modify it without notice and to improve and/or modify the product described in this manual. See the website www.fracarro.com to have information relevant to the technical support and product guarantee.
User not only can use front buttons to set configuration, but also can control and set the configuration in computer by connecting the device to web NMS Port. User should ensure that the computer’s IP address is different from the SIG7412 T MPEG2’s IP address; otherwise, it would cause IP conflict.
3.2 Encoder Modulator Operation Status When we login into encoder module, it displays the status interface as Figure 2. Current software version information User can click any item here to enter the corresponding interface to check information or set the parameters. Figure 2 pag11...
Page 12
Parameters → Module 1 SIG7412 T MPEG2 support up to 12 CVBS input. From the menu on left side of the webpage, clicking “Module 1”, it displays the information of each encoding channel as Figure 3. General settings for the Encoding...
Page 13
Parameters → Tuner: From the menu on left side of the webpage, clicking “Tuner”, it displays the interface where users can configure the Tuner input parameters as Figure 4. Figure 4 pag13...
Page 14
Parameters → TS Config: From the menu on left side of the webpage, clicking “TS Config”, it displays the interface where users can configure the TS output parameters. TS Config→Output TS X: From the menu on up side of the webpage, clicking “Output TS X”, it displays the interface where users can select the TS output carrier (Figure 5) Figure5 Figure 5...
Page 15
TS Config→Stream select: From the menu on up side of the webpage, clicking “Stream select”, it displays the interface where users can select program(s) to multiplex out and modify program info. (Figure 6) Input Area Output Area Operation Area Figure 6 pag15...
Page 16
Configure ‘Input Area’ and ‘Output Area’ with buttons in ‘Operation Area’. Instructions are as below: : To edit the input channel : To delete the input channel : To delete all inputs channel : To check input IP lock or not, green means current IP locked : To check current TS overflow or not, red color means current TS overflow, need reduce program : To filter/not filter the source CA information...
Page 17
TS Config→General: From the TS Config menu on up side of the webpage, clicking “General”, it displays the interface where users can set output mode, enable PSI/SI table out, NIT insert/VCT insert, PCR correction. (Figure 8) Figure 8 pag17...
Page 18
TS Config→PID Bypass: From the TS Config menu on up side of the webpage, clicking “PID Bypass”, it displays the interface as Figure9 where user can add PIDs to be passed, click the “+” symbol, input current IP channel number, then input current IP source Pid and output Pid which is customer needed , then click “set”...
Page 19
Parameters → Modulator: From the menu on left side of the webpage, clicking “Modulator”, it will display the Modulator Configuration screen as Figure 10. Here user can set modulation parameters. Quickly Config Channel Config Figure 10 pag19...
Page 20
Parameters → IP Stream: SIG7412 T MPEG2 supports TS to output in IP (Max 128 IP) format through the DATA1 and DATA2 port. Click ‘IP Stream’, it will display the interface where to set IP out parameters (Figure 11). Quickly Config...
Page 21
System → Network: Click ‘Network’, it will display the interface as Figure 12 where to set network parameters. Figure 12 pag21...
Page 22
System → password From the menu on left side of the webpage, clicking “Password”, it will display the screen as Figure 13 where to set the login account and password for the web NMS. Figure 13 pag22...
Page 23
System → Configuration: From the menu on left side of the webpage, clicking “Configuration”, it will display the Screen as Figure 14 where to save/restore/factory setting/backup/load your configurations. Figure 14 pag23...
Page 24
System → Firmware: From the menu on left side of the webpage, clicking “Firmware”, it will display the screen as Figure 15 where to update firmware for the modulator. Figure 15 pag24...
Page 25
System→ Date/Time: From the menu on left side of the webpage, clicking “Date/Time”, it will display the screen as Figure 16 where to set date and time for the device. Figure 16 pag25...
Page 26
System→ Log: From the menu on left side of the webpage, clicking “Log”, it will display the log interface as Figure 17 where to check or export the Kernel/System log. Figure 17 pag26...
Chapter 4 Troubleshooting For guarantee the products’ quality, reliability and stability. All Fracarro products have been passed the testing and inspection before ship out factory. The testing and inspection scheme already covers all the Optical, Electronic and Mechanical criteria which have been published by Fracarro. To prevent potential hazard, please strictly follow the operation conditions.
I contenuti di questo documento sono soggetti a revisione senza preavviso a causa dei continui progressi nella metodologia, nella progettazione e nella produzione. Fracarro non avrà alcuna responsabilità per eventuali errori o danni di qualsiasi tipo derivanti dall'uso di questo documento.
Page 30
Indice Informazioni su questo manuale..............29 Capitolo 1 Introduzione................31 1.1 Panoramica del prodotto............................31 1.2 Caratteristiche principali.............................31 1.3 Specifiche................................32 1.4 Flow Chart principale............................33 1.5 Aspetto e Descrizione............................34 Capitolo 2 Guida all’installazione...............35 2.1 AVVERTENZE PER LA SICUREZZA......................35 2.2 Avvertenze per l’installazione..........................35 2.3 Avvertenze generali............................36 2.4 CONFORMITA’...
Capitolo 1 Introduzione 1.1 Panoramica del prodotto L’encoder 12 in 1 SIG7412 T MPEG2 è un prodotto Fracarro che integra la codifica MPEG2, il Multiplexing e la modulazione in DVB-T. Supporta 12 ingressi CVBS. Ha una uscita RF DVB-T, con 4 MUX adiacenti (50MHz~960MHz) , e la porta di uscita Data1 (GE) per gestire 4 MPTS in uscita.
Aggiornamento software via Ethernet Dimensioni (L×P×A) 482mm×410mm×44mm Peso approsimativo Temperature 0~45℃(T di lavoro);20~80℃(Stoccaggio) Varie Requisiti di alimentazione AC 110V± 10%, 50/60Hz, AC 220 ± 10%, 50/60Hz Consumo massimo SIG7412 T MPEG2 Nome Prodotto 287610 Codice Prodotto 1.4 Flow Chart principale pag33...
1.5 Aspetto e Descrizione Immagini del pannello frontale e posteriore connettori RF test ed RF out Ingresso Alimenzione e connettore messa a terra 12 ingressi CVBS (da Q9 a RCA) Tastino Reset/Indicatore Data Port Led di funzionamento Porte DATA 1/2 (Per IP stream input/output) pag34...
L’installazione del prodotto deve essere eseguita da personale qualificato in conformità alle leggi e normative locali sulla sicurezza. Fracarro Radioindustrie di conseguenza è esonerata da qualsivoglia responsabilità civile o penale conseguente a violazioni delle norme giuridiche vigenti in materia e derivanti dall’uso improprio del prodotto da parte dell’installatore, dell’utilizzatore o di terzi.
In caso di guasto non tentate di riparare il prodotto altrimenti la garanzia non sarà più valida. Utilizzare esclusivamente l’alimentatore fornito in dotazione con il prodotto. Le informazioni riportate in questo manuale sono state compilate con cura, tuttavia Fracarro Radioindustrie S.r.l. si riserva il diritto di apportare in ogni momento e senza preavviso, miglioramenti e/o modifiche ai prodotti descritti nel presente manuale.
Capitolo 3 Interfaccia WEB NMS Il prodotto può essere configurato basicamente dai tasti frontali. La programmazione completa si effettua via interfaccia WEB NMS sull’apposita porta. Verificare che l’indirizzo IP del PC sia diverso dall’indirizzo IP del prodotto, in caso contrario modificarlo per evitare un conflitto IP. 3.1 Accesso all’Interfaccia WEB L’indirizzo IP predefinito del prodotto è...
3.2 Operazioni sul modulatore dell’Encoder Status Quando si accede al menu di programmazione, compare la schermata di Figura 2. Informazioni sulla versione software attuale Cliccare su una qualunque delle voci per accedere al menu corrispondente ed impostarne i parametri Figura 2 pag38...
Page 39
Parametri → Module 1 Il prodotto gestisce fino a 12 ingressi CVBS. Dal menu di sinistra, cliccando “Module 1”, vengono mostrate le impostazioni di ciascun canale di codifica, come in Figura 3. Impostazioni generali di codifica: è possibile modificare ogni parametro in base alle impostazioni volute...
Page 40
Parametri → Tuner: Dal menu di sinistra, cliccando su “Tuner”, viene visualizzato il menu di configurazione dei parametri di ingresso del Tuner 1, come in Figura 4. Figura 4 pag40...
Page 41
Parametri → TS Config: Cliccando su “TS Config” viene visualizzato il menu di configurazione dei parametri di sucita del TS TS Config→Output TS X: Cliccando su “Output TS X”, viene visualizzato il menu di configurazione del TS di uscita, come in Figura 5. Figure5 Figura 5 pag41...
Page 42
TS Config→Stream select: Cliccando su “Stream select”, viene visualizzato il menu di configurazione in cui selezionare i programmi da multiplexare in uscita. E’ possibile codificare le informazioni di ogni singolo programma selezionato, come in Figura 6. Sezione Input Sezione Output Sezione Operazioni Figura 6 pag42...
Page 43
Configurare ‘Input Area’ e ‘Output Area’ con il menu presente in ‘ Sezione Operazioni’, come di seguito riportato: : Modifica i parametri del programma selezionato in ingresso : Cancella il programma selezionato : Cancella tutti i programmi : Indica se un input IP è agganciato o no, verde indica che l’input IP è agganciato : Indica se c’è...
Page 44
TS Config→Generale: Dal menu TS Config nella parte sinistra della web interface, selezionando“General”, viene visualizzato il menu di figura 8, in cui è possibile impostare il tipo di output abilitare le tabelle PSI/SI in uscita , i parametri NIT /VCT , ed abilitare la correzione PCR, come indicato in Figura 8.
Page 45
TS Config→ID Bypass: Dal menu TS Config, selezionando “PID Bypass”, viene visualizzata l’interfaccia di Figura 9 , dove è possibile selezionare e modificare i PIDs da mandare in uscita. Selezionare il simbolo “+” , inserire il numero del programma IP da elaborare, quindi inserire il PID della sorgente IP in ingresso ed il Pid di uscita voluto, quindi cliccare su “set”...
Page 46
Parametri → Modulatore: Dal menu nella parte sinistra della web interface, selezionando “Modulator”, viene visualizzato il menu di configurazione del modulatore come in Figura 10. Da qui è possibile impostare i parametri di modulazione. Config. rapida Config Canali Figure 10 pag46...
Page 47
Parametri → IP Stream: Il prodotto supporta TS in uscita in formato IP (Max 128 IP) dalle porte DATA1 e DATA2 . Selezionare ‘IP Stream’, viene visualizzato il menu di Figura 11 in cui impostare i parametri di uscita IP. Config rapida Config Canali Figura 11...
Page 48
System → Network: Selezionare ‘Network’, viene visualizzata l’interfaccia di Figura 12 dove è possibile impostare i parametri di rete. Figura 12 pag48...
Page 49
System → password Dal menu nella parte sinistra della web interface, selezionando “Password”, viene visualizzato il menu di Figura 13, da dove è possibile impostare Username e Password per l’accesso all’interfaccia web di programmazione. Figura 13 pag49...
Page 50
System → Configuration: Dal menu nella parte sinistra della web interface, selezionando “Configuration”, viene visualizzato il menu di Figura 14, da dove è possibile salvare/ripristinare/riportare alle impostazioni di fabbrica/ fare backup/caricare la configurazione creata. Figura 14 pag50...
Page 51
System → Firmware: Dal menu nella parte sinistra della web interface, selezionando “Firmware”, viene visualizzato il menu di Figura 15, da cui aggiornare il firmware del prodotto. Figura 15 pag51...
Page 52
System→ Date/Time: Dal menu nella parte sinistra della web interface, selezionando “Date/Time”, viene visualizzato il menu di Figura 16, da cui impostare data ed orario del prodotto. Figura 16 pag52...
Page 53
System→ Log: Dal menu nella parte sinistra della web interface, selezionando “Log”, viene visualizzato il menu di Figura 17, da cui è possibile controllare ed esportare il file Kernel/Log di sistema. Figura 17 pag53...
Capitolo 4 Ricerca guasti Tutti i prodotti Fracarro vengono testati nelle loro componenti ottiche, elettroniche e meccaniche, per garantirne la qualità, la stabilità e l’affidabilità nel tempo. Per prevenire eventuali pericoli si prega di seguire le indicazioni di installazione e funzionamento.
Need help?
Do you have a question about the SIG7412 T MPEG2 and is the answer not in the manual?
Questions and answers