ImicTek IMIC-ME20 User Manual

ImicTek IMIC-ME20 User Manual

Digital thermometer-hygrometer

Advertisement

Quick Links

Digital Thermometer-Hygrometer
User's Manual

1. Introduction

Thank you for purchasing our Digital Thermometer-Hygrometer. Please
take a few minutes to browse through this user manual before you
begin to operate the meter to ensure that you are fully familiarized with
how best to operate the meter as accurately and safely as possible.
This product is for indoor use, only. It uses a high-speed microprocessor
and a high-precision digital sensor, which can quickly and accurately
measure the current environmental temperature and humidity. It is
useful in homes, offices, warehouses, laboratories, greenhouses, etc.

2. Specifications

Name:Digital Thermometer-Hygrometer
Model:IMIC-ME20
Standard:QB/WSDJ ME2X-2019
Temperature:-10~60.0℃(14~140℉),Resolution0.1℃,Accuracy±0.3℃
Humidity:0~99%RH,Resolution1%RH,Accuracy±3%RH
Calibration Range:±9.9℉/±9%RH
Sample rate:default 5 seconds,Adjustable range 1~60seconds
Dimension:80 x 80 x 13mm
Weight:62g
Battery:CR2032,DC3V

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IMIC-ME20 and is the answer not in the manual?

Questions and answers

Summary of Contents for ImicTek IMIC-ME20

  • Page 1 It is useful in homes, offices, warehouses, laboratories, greenhouses, etc. 2. Specifications Name:Digital Thermometer-Hygrometer Model:IMIC-ME20 Standard:QB/WSDJ ME2X-2019 Temperature:-10~60.0℃(14~140℉),Resolution0.1℃,Accuracy±0.3℃ Humidity:0~99%RH,Resolution1%RH,Accuracy±3%RH Calibration Range:±9.9℉/±9%RH Sample rate:default 5 seconds,Adjustable range 1~60seconds Dimension:80 x 80 x 13mm...
  • Page 2 3. Panel information Temperature display Bluetooth indicator Low power indicator Humidity and Units Comfort level indicator Temperature units Comfort Level Indicator -- Comfortable --Uncomfortable ºF ºF ºF ºF Temp.<68 ≤Temp.≤78.8 Temp.>78.8 Humidity<30% or >60% 30% <Humidity<60% Low power indicator When the batter y voltage drops below proper operation range, the symbol will appear on the LCD display and the batter y will need to be replaced.
  • Page 5 c. Select Degrees Fahrenheit or Celsius Press the button to select degrees in Fahrenheit (ºF) or Celsius (ºC). d. Adjust Sampling Rate The default sample rate is 5 seconds after each power-on. If you need to adjust the increment, press SET button for 5 seconds to enter the setting mode. Press the button to choose the sampling timebetween 1 - 60 seconds.
  • Page 6 Face lcon Display Mode To remove,or display, comfort level indicator(face icon)single press“SET”button. How to Calibrate: (Note:Calibrations will be reset when batter y is removed.) a. To access calibration mode, press both “SET”and “△” buttons simultaneously for at least 5 seconds, until display shows calibration page. Then release buttons.
  • Page 7 6. Precautions and notes a. Do not use in high temperature and humidity environment for an extended period of time. b. Avoid prolonged exposure to volatile chemicals. c. Please use gentle detergent to clean product’s surface if needed. d. Upon initial use, allow for a 30 minute lag time for monitor to register the correct data.