E2S BExBG05D-P Instruction Manual

E2S BExBG05D-P Instruction Manual

Hide thumbs Also See for BExBG05D-P:

Advertisement

Quick Links

INSTRUCTION MANUAL
BExBG05D-P
Xenon Beacon
ATEx/IECEx & UKEx Gas & Dust
1. Product Table
It is important that a suitable power supply is used to run the equipment. The power supply selected must have the necessary capacity
to provide the input current to all of the units.
The above table shows the input current taken by the various beacons and shows the maximum voltage at which the beacons can be
operated:
The input current will vary according to the voltage input level.
2. Warnings
DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT
DO NOT OPEN WHEN ENERGIZED
POTENTIAL ELECTROSTATIC CHARGING HAZARD – CLEAN ONLY WITH A DAMP CLOTH
COVER BOLTS CLASS A4-80
USE HEAT RESISTING CABLES AND CABLE GLANDS (RATED 110°C) AT AMB. TEMPERATURES OVER
40°C
European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH
Document No. D210-00-201-IS
Nominal
Unit Type Code
Input Voltage
BExBG05DPDC012
12Vdc
BExBG05DPDC024
24Vdc
BExBG05DPDC048
48Vdc
BExBG05DPAC115
115Vac
BExBG05DPAC230
230Vac
Issue 5
BExBG05D-P
Nominal
Input Current
750mA
300mA
180mA
140mA
55mA
12-09-2022
Max I/P Voltage
14V
28V
54V
126V
253V
www.e2s.com
Tel: +44 (0)208 743 8880
Sheet 1 of 6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BExBG05D-P and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for E2S BExBG05D-P

  • Page 1 INSTRUCTION MANUAL BExBG05D-P Xenon Beacon ATEx/IECEx & UKEx Gas & Dust BExBG05D-P 1. Product Table Nominal Nominal Unit Type Code Max I/P Voltage Input Voltage Input Current BExBG05DPDC012 12Vdc 750mA BExBG05DPDC024 24Vdc 300mA BExBG05DPDC048 48Vdc 180mA BExBG05DPAC115 115Vac 140mA 126V...
  • Page 2 4. Zones, Gas Group, Category and 3. Marking & Rating Information Temperature Classification The BExBG05D-P comply with the following standards for hazardous The units can be installed in locations with the following conditions: locations: 3.1 ATEX / IECEx & UKEx Ratings...
  • Page 3: Special Conditions For Safe Use

    Never use the cover bolts to force the cover into position. European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No. D210-00-201-IS Issue 5...
  • Page 4: Cable Connections

    When using the internal earth terminal ensure that the stainless steel M4 flat washer is between the incoming earth wire and the enclosure. European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No. D210-00-201-IS Issue 5...
  • Page 5: Wiring Diagram

    (see figure 7) on one of the two beacons. The first flash on the beacon that has the header fitted will be On BExBG05D-P DC units, dc reverse line monitoring can be delayed by ½ second. The two beacons will then flash used if required.
  • Page 6: Maintenance, Overhaul & Repair

    M5 Plain Washer equipment. Guard The beacon cover is interchangeable, contact E2S Ltd for a Cover replacement cover available in various colours. To change the cover, unscrew the M5 socket head screws and Fig. 10 Cover and Guard Fixtures remove the M5 screws, M5 spring &...
  • Page 9: Eu Declaration Of Conformity

    EN 60529:1991 + A1:2000 + A2:2013. - Degrees of protection provided by enclosures (IP code) – enclosure rated IP66/67 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC-004_Issue_N (BExBG) - Page 1 of 2 - QAF_252_Issue_5...
  • Page 10 This Declaration is issued under the sole responsibility of the manufacturer. Martin Streetz Document No.: DC-004_Issue_N Quality Assurance Manager Date and Place of Issue: London, 20/04/2022 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC-004_Issue_N (BExBG) - Page 2 of 2 - QAF_252_Issue_5...
  • Page 11: Equipment Type

    EN 60529:1991 / A1:2000 / A2:2013 - Degrees of protection provided by enclosures (IP code) – enclosure rated IP66/67 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC-105_Issue_A (BExBG)- Page 1 of 2 - QAF_252_Issue_5...
  • Page 12 This Declaration is issued under the sole responsibility of the manufacturer. Martin Streetz Document No.: DC-105_Issue_A Quality Assurance Manager Date and Place of Issue: London, 12/09/2022 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC-105_Issue_A (BExBG) - Page 2 of 2 - QAF_252_Issue_5...

Table of Contents