Download Print this page

Advertisement

Quick Links

Installation and Maintenance
Installation et Maintenance
Installation and Maintenance
Installazione e Manutenzione
Installation et Maintenance
Instalación y Mantenimiento
Installazione e Manutenzione
Instalación y Mantenimiento
Models : Modèles : Modelle : Modelli : Modelos : 型号
S200 : S400 : S800 : FX 4002 : FX5002 : FX6002 : FX7002
Models : Modèles : Modelle : Modelli : Modelos : 型号
F Monitor
S200 : S400 : S800 : FX 4002 : FX5002 : FX6002 : FX7002
F Monitor 2 & 2+
INSTALLATION MANUAL
INSTALLATION MANUAL
INSTALLATION MANUAL
Installation und Wartung
Installation und Wartung
安装与维护
安装与维护
Product Installation Manual
F-MONITOR + ALL UNITS
Product Installation Manual
Product Installation Manual
F-MONITOR + ALL UNITS
F-MONITOR + ALL UNITS
2
& 2+

Advertisement

loading

Summary of Contents for FILTERMIST F Monitor 2

  • Page 1 Models : Modèles : Modelle : Modelli : Modelos : 型号 F Monitor & 2+ S200 : S400 : S800 : FX 4002 : FX5002 : FX6002 : FX7002 F Monitor 2 & 2+ INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL...
  • Page 2 Product Installation Manual F-MONITOR + ALL UNITS The F Monitor 2 is a monitoring device that measures airflow and time to indicate when the Filtermist needs servicing, or if there are any blockages in the extraction system which may be affecting performance. F Monitor 2+ uses a sensor to provide additional functionality The F-Monitor is a monitoring device that measures airflow and time to indicate when the which measures vibration and motor temperature.
  • Page 3 Fix the mounting plate into desired position. Fix the mounting plate into desired position. The F Monitor 2 slides into place on the mounting plate. The F Monitor 2 slides into place on the mounting plate. All text, images and photographs Copyright Filtermist International 2019...
  • Page 4 The F-Monitor comes with 3 metres of cable already prewired. If a longer length is The F Monitor 2 comes with 3 metres of cable already prewired. If a longer length is needed ensure it is connected as shown above.
  • Page 5 Connection for motors with 6 pin terminal blocks F-MONITOR F-MONITOR TERRA EARTH TERRA EARTH TERRA TERRA LOW VOLTAGE HIGH VOLTAGE Connect the monitor cable to the motor terminal block. Live and Neutral can be connected to either terminal. All text, images and photographs Copyright Filtermist International 2019...
  • Page 6 F Monitor 2 & 2+ Optional signal switch can be connected to control panel/traffic light system as an additional signal of the F Monitor 2’s status Remove plug to access the optional output signal if desired. There are 2 options for the volt free relay error signal.
  • Page 7 F-MONITOR + ALL UNITS F Monitor 2 & 2+ To connect the monitor to the Filtermist unit fit the nozzle to the diaphragm To connect the monitor to the Filtermist unit fit the nozzle to the diaphragm Connect tube from the F-Monitor fixed spigot 1 to the nozzle...
  • Page 8 IMPORTANT – When fitted with an Afterfilter, ensure tubes are not pinched or trapped as this will affect the function of the F-Monitor. (It may pinched or trapped as this will affect the function of the F Monitor 2. It be necessary to enlarge the seal cut-out)
  • Page 9 F Monitor 2 & 2+ F-MONITOR + ALL UNITS For Filtermist units that are already in operation or without the pre-drilled hole in the exhaust diaphragm the following instructions should be followed. IMPORTANT – When fitting the F Monitor 2 to units already installed it is important that the unit is serviced and that the ducting and extraction point are clean.
  • Page 10 10. instructions as per image 9 All text, images and photographs Copyright Filtermist International 2019 Optional: Use the hole on the side of the motor to attach the sensor, ensure that the sensor is secure and rigid - there must be a gap between the motor and the...
  • Page 11 F Monitor 2 & 2+ F Monitor 2 settings using app from Apple app store F Monitor 2 settings using app from Apple app store Make sure the Filtermist unit is running. Click 'scan' and select the code showing Download the Filtermist app from the Apple...
  • Page 12 F Monitor settings using app F Monitor 2 & 2+ Make sure unit is running. Download the app from Tools -> Pair sensor, enter the MAC number located on the side Tools -> Pair sensor ,MAC number located on the side of Scan and select of the sensor and press save.
  • Page 13 F Monitor 2 you want to inside the u must match code on side of unit) Google Play and open Monitor settings using app from Google play store...
  • Page 14 F Monitor 2 & 2+ F Monitor settings using app from Google play sto F Monitor settings usin Make sure unit is running. Make sure unit is running. Leave default setting (as shown) or Tools -> Pair sensor, enter MAC number...
  • Page 15 (MAC limits as maintenance Blow compressed air down the tube towards the nozzle, not towards the F Monitor 2 Blow compressed air down the tube towards the nozzle, not towards the F Monitor 2 inside) if present d and then...
  • Page 16 Product Installation Manual F Monitor 2 & 2+ F-MONITOR + ALL UNITS Make sure the wire mesh has no blockages. Make sure the ducting has no blockages. All text, images and photographs Copyright Filtermist International 2019...
  • Page 17 Product Installation Manual F-MONITOR + ALL UNITS F Monitor 2 & 2+ Make sure the Afterfilter isn’t blocked by removing it from the Filtermist unit. All text, images and photographs Copyright Filtermist International 2019...
  • Page 18 F Monitor 2 & 2+ Demo Film EU DECLARATION OF CONFORMITY Scan the QR code to see the F Monitor 2 & 2+ in use or visit: www.filtermist.com/oil-mist-collectors/oil-mist-collector-accessories/service-and-spares.aspx Manufacturer’s Filtermist International Limited Equipment covered by this declaration: name: Description: Monitoring device for Filtermist units...
  • Page 19: Ec Declaration Of Conformity

    Group Engineering Manager company: company: Signature: � Signature: Place of Filtermist International Limited, Telford 54 Business Park, Declaration: Nedge Hill, Telford, Shropshire, TF3 3AL Place of Filtermist International Limited, Telford 54 Business Park, Declaration: Nedge Hill, Telford, Shropshire, TF3 3AL, England...
  • Page 20 G* G* Demo Film G* G* Scan the QR code to see the F Monitor 2 & 2+ in use or visit: www.filtermist.com/oil-mist-collectors/oil-mist-collector-accessories/service-and-spares.aspx This manual is also available in German, Spanish, Chinese, Japanese & French. Please contact your local distributor for information, details at www.filtermist.com...

This manual is also suitable for: