philippi VSR 200 Instruction Manual

Advertisement

Quick Links

V S R 2 0 0
k

USE

The VSR 200 is a voltage-dependent switching isolating relay. It is used for automatic Inter-
Connection of two battery groups (e.g. starter / consumer battery or starter / bug battery)bat-
tery) in charging mode.
The VSR 200 measures the voltage of both battery groups at the connection bolts and swit-
ches them together as soon as the voltage at one of the two battery groups is above the
switch-on threshold. If the charging equipment (alternator, chargers, wind / solar) stops sup-
plying energy, the voltage drops and the relay automatically disconnects the two battery
groups as soon as the voltage falls below the switch-off threshold. In addition, the battery
banks can be disconnected during the starting process.
The VSR 200 can be activated in an emergency by manual operation at the relay or by an
optional control button to establish a connection between the battery groups in order to
select the motor from both batteries (emergency start function).
The VSR 200 is designed for continuous currents up to 200 A and has a very low self-cur-
rentconsumption.The voltage-dependent switching isolating relay VSR 200 can only be ope-
rated on DC low voltage 9 - 32V.
It is designed for use on yachts or in mobile homes and may only be used in closed rooms
that are protected from rain, humidity, dust and condensation water. Never use the voltage-
dependent switching isolating relay VSR 200 in places where there is a risk of explosion due
to gas or dust. It is not suitable for outdoor installation.
philippi elektrische systeme gmbh
Neckaraue 19
D-71686 Remseck am Neckar
V2.2 - APR 2014
INSTRUCTION MANUAL
www.philippi-online.de
info@philippi-online.de
Telefon: +49 (0)7146/ 8744-0, Fax -22

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VSR 200 and is the answer not in the manual?

Questions and answers

Summary of Contents for philippi VSR 200

  • Page 1 The VSR 200 can be activated in an emergency by manual operation at the relay or by an optional control button to establish a connection between the battery groups in order to select the motor from both batteries (emergency start function).
  • Page 2 V S R 2 0 0 WARRANTY philippi elektrische systeme gmbh grants a two year limited and non-transferable warranty for the first buyer of this equipment, commencing on the date of purchase and covers defects in manufacturing, parts and materials.
  • Page 3 V S R 2 0 0 INSTALLATION - Mount the device close to the battery / battery bank in an easily accessible location, so that a manual emergency operation is possible. - The installation location should be cool and dry if possible. - Provide strain relief for the cables (at a maximum distance of 30 cm) CONNECTION - The batteries must be disconnected before installation!- The wire cross section of the connecting lines...
  • Page 4 V S R 2 0 0 OPERATION The internal LED shows by a simple flash the readiness for operation in 12V mode. The double flashing indicates the 24V mode. When the relay is switched on, the internal LED and the optional external LED light up.

This manual is also suitable for:

7 0001 0120

Table of Contents