FOREHEAD THERMOMETER FOR FEVER
OBJECT SURFACE THERMOMETER
OPERATION MANUAL
1.
SAFETY RULES
To ensure the device is used safely, follow the operation manual's safety and operating
instructions. If the device is not used as described in this operation manual, the safety
features of this device might be impaired.
Keep out of reach of children.
2.
INTERNATIONAL SYMBOLS
Important information
see manual
3.
SPECIFICATIONS
Description
Infrared Thermometer Forehead & Object surface types
Body Temperature 32.0 ~ 42.9°C (89.6 ~ 109.2°F)
Measurement Range
Object surface Temperature 0.0 ~ 200.0°C (32.0 ~ 392.0°F)
Accuracy in °C /
Within range 35.0 °C ~ 42.0 °C : ± 0.2 °C
Body Temperature Mode
Out of range (2 ~10 cm) 35.0 °C ~ 42.0 °C : ± 0.3 °C
Accuracy in °C /
Within range 0.0 °C ~ 200.0 °C : ± 0.4 °C
Object Temperature Mode
Out of range (2 ~ 10 cm) 0.0 °C ~ 200.0 °C : ± 0.6 °C
Memories
32 Recalls (Forehead type only)
Measuring Distance
2 ~ 10 cm
Atmospheric Pressure
70 kpa ~ 106 kpa
Indicating Unit Resolution
0.1 °C
Operating Temperature
10 °C ~ 40 °C
Automatic Sleep Mode
After 30 Sec.
Language
Bilingual- English & Chinese (Default English)
Battery
6F22 9V (Alkaline battery recommended)
Product Size (L x W x H)
10 cm x 4.6 cm x 16 cm
Product Weight
125g (Without Battery)
4.
THERMOMETER DESCRIPTIONS
The Thermometer is a non-contact infrared thermometer and always with Real-Time Maximum
(MAX) data. Please remember to keep away from children and not use them for safety-related
issues.
1. Infrared Sensor
2. Measuring Port
3. LCD Screen
4. "Body Temp (Default) or
Object Temp (Blank) mode
5. Buzzer
6. Backlight
7. °C / °F
8. "+" Button
9. "-" Button
10. "M" Function enable Button
11. Backlight Button
12. Buzzer Button
13. Measuring Button
14. Battery Cover
15. Handle
BT-61
2
1
4
3
8
11
13
14
5.
OPERATION
WARNING
1)
Do not place the device too close to the electromagnetic scope. (Radio, mobile
phone, etc.)
2)
Hair and sweat on the forehead may affect the accuracy of measurements. Different
skin colours and thicknesses may give slightly different measuring temperatures.
3)
When the tested person comes from a different temperature environment, one shall
stay in the measuring environment for 15 minutes before measuring.
4)
The condition of the measuring spot should be stable without ample airflow, i.e. Fan
or air-con blower.
5)
Do not take measurements in a place near strong sunlight.
6)
The use of this Thermometer is not a substitute for a doctor's diagnosis.
5.1
Three-colours screen fever guidance
Display
5.2
Function Selection
Body temperature and
Object temperature
switching
Memory (Only on Body
temperature mode)
5
Measure non-body
6
temperature
7
°C or °F
Backlight
9
Sound
English and Chinese
10
mode switching
12
5.4
LCD Error Messages
The Thermometer incorporates visual diagnostic messages as follows:
15
Function
Normal - Green backlight 34~37.3 °C
High - Amber backlight 37.4~38 °C
Fever - Red backlight 38.1~42.9 °C
The default setting of the Thermometer is Body temperature.
Change to Object temperature: press and hold the "M"
button, and click the buzzer button to measure Object surface
temperature (note: Object temperature has no icon shown on
LCD).
Change to Body temperature: press and hold the "M" button
and click the backlight button to measure body temperature
(note: Body temperature has an icon on LCD).
Historical data viewing: The instrument will automatically
record up to 32 historical measurement data. To view data,
quickly press the "M" button & release and then "+" or
"-". Press "-"to view the last temperature record, and press
"+" for the farthest record. Press + or – again to view them
one by one.
The sequence of the 32 memories data will follow by the
relevant readings.
When you need to measure non-body temperature
(object surface temperature), it can be switched to object
temperature mode as described above.
Press and hold the "M" button, and click the "+" Button.
Short press the backlight button to turn the backlight on or off.
Short press the buzzer button to turn the sound on or off.
Press and hold the "M" button, and click the "-" Button.
(Default is English)
'Hi' or 'Lo' is displayed when the temperature being
measured is outside of the measurement range. It is invalid
measurement. These measurement results will not be
recorded nor counted.

Advertisement

loading

Summary of Contents for BSi BT-61

  • Page 1 BT-61 FOREHEAD THERMOMETER FOR FEVER OPERATION OBJECT SURFACE THERMOMETER WARNING Do not place the device too close to the electromagnetic scope. (Radio, mobile OPERATION MANUAL phone, etc.) Hair and sweat on the forehead may affect the accuracy of measurements. Different skin colours and thicknesses may give slightly different measuring temperatures.
  • Page 2 Allowing the lens to dry entirely before using the Thermometer. Do not submerge any part of the Thermometer. The Thermometer should be stored at room temperature between -20 to +65°C (-4~149°F) and 85% of relative humidity with no condensation or less. BT-61 REV1.0/AUG22 ACCESSORIES The accessories contained inside the packaging are the following: •...