Do you have a question about the TPS-1305R and is the answer not in the manual?
Questions and answers
Summary of Contents for TECPEL TPS-1305R
Page 1
Single Channel Output DC Power Supply User Manual TPS-1305R...
Page 2
The informa=on in this manual was correct at the =me of prin=ng. However, TECPEL will con=nue to improve products and reserves the rights to change specifica=on at any =me without no=ce.
1.General Safety Requirements 1.General Safety Requirements Before use, please read the following safety precau8ons to avoid any possible bodily injury and to prevent this product or any other connected products from damage. To avoid any con8ngent danger, ensure this product is only used within the ranges specified.
3.Quick Review 2.Safety Terms and Symbols Safety Terms Terms in this manual (The following terms may appear in this manual): Warning: Warning indicates condi=ons or prac=ces that could result in injury or loss of life. Cau8on: Cau=on indicates the condi=ons or prac=ces that could result in damage to this product or other property.
3.Quick Review 3.Quick Review 3.1.Panel and Interface 3.1.1.Front Panel Figure 31 Front Panel Overview ① Display Area Display user interface. ② Direc8on Key Select menu; select parameters; Edit the cursor. OK Key 1) Enter the menu or confirm the entered parameters. 2) Switch the display mode between Number and Curve.
3.Quick Review ⑦ Keylock Key Press and hold this buMon for about 5 seconds. When you hear a beep, the panel is locked and the lock icon is displayed on the top of the screen. When locked, pressing any other key has no effect. In the locked state, press and hold this buMon for about 5 seconds.
3.Quick Review ⑤ COM port Connect the serial port of the instrument and external device 3.1.3.User Interface Channel output status Constant Voltage output Constant Current outpu Buzzer status Actual voltage output Set values of voltage Actual current output Set values of current Set values of O.V.P Actual power output Set values of O.C.P...
3.Quick Review 3.3.Power Inspection (1) Use the power cord supplied with the accessories to connect the instrument to the AC power. Warning: To prevent electric shock, make sure that the instrument is properly grounded. (2) Press the power buXon on the front panel, the buMon light will be on, and the startup screen will be displayed on the screen.
Page 10
3.Quick Review (6) Turn off the channel output and remove the short circuit from the output terminals.
3.Quick Review 4.Panel Operation 4.1.Turn On/Off the Channel Output Press the On/Off key to turn on/off the channel; 4.2.Set the Output Voltage/Current In the channel setting area, press the ∧ / ∨ keys to move the red cursor between parameters. After selecting the output voltage/current setting value, turn the knob to change the current cursor value, and press <...
3.Quick Review Set values of O.V.P Set values of O.C.P 4.4. Memory key shortcut settings Memory Press key on front panel, the M1, M2, and M3 keys can store five sets of channel parameters M1, M2, M3, M4, and M5, respectively, for quick output. 4.4.1.Quick output To output a set of parameters from M1 to M5, follow these steps: (1) Press Memory key on front panel, the shortcut interface will display.
3.Quick Review 4.5.System Settings 4.5.1.Display Brightness Press the System softkey and turn the knob to highlight the System main menu. Press the ∨ keys to highlight the Brightness submenu. Press the < / > keys to adjust the brightness of the screen. The adjustment range is from 1 to 100. 4.5.2.Language Setting Press the System...
Page 14
3.Quick Review to set the display mode to Number. In system main interface, you can also press the OK key or press the knob to select the Number display mode. When the power supply is powered on, the default display mode is Number.
Page 15
3.Quick Review Note: In Volt curve display mode, you can still set the value of voltage or current. Press < / > knob arrow keys or turn the to enter editing mode (edit voltage first). If the value is not changed, editing mode will be exited. 2) Current Curve Two methods to set the curve type to current curve.
3.Quick Review Curve Time Press the oftkey and turn the to select the [Utility] menu. Press the System s knob ∨ < / > arrow keys to choose CurveTime submenu. Press the arrow keys or turn the to set the display mode to Curve. Press the arrow keys to choose CurveTime knob ∨...
3.Quick Review 4.7.2.Restore Factory Settings Press the softkey and turn the to select the [SYSTEM] menu. Press System knob ∨ arrow keys to select the Factory Reset submenu. Press to restore the factory default settings. See the factory setting detail table below Voltage Current Output...
3.Quick Review 5.Troubleshoo8ng 1. The instrument is powered on but no Display. Check if the power is connected properly. ● Check if the fuse which is below the AC Power socket is used appropriately ● and in good condi=on (the cover can be pried open with a straight screwdriver).
3.Quick Review 6.2.Appendix B: General Care and Cleaning General Care Do not store or leave the instrument where the liquid crystal display could be exposed to direct sunlight for long periods of time. Caution: To avoid any damage to the instrument, do not exposed it to any sprays, liquids, or solvents.