Contents
(1) Eagle Eye Elite IV
Electrolyte Level Sensor
(1) Instruction Sheet
1
Neg
Locate your battery posts (positive and
negative). We recommend that you place the
probe as close to the center of the pack as
possible (indicated in green above). Probe
cannot be installed within three cells
from a battery post (red or black area as
shown above).
BL-643-0721
Eagle Eye Elite IV
In-Valve Battery Level Sensor
INSTALLATION
& OPERATION INSTRUCTIONS
for Part Numbers:
Tools Required
PPE
(4) Zip ties
Torque wrench w/
proper sized socket
(1) Swivel tee
Pos
EA-222, EA-223, EA-224, EA-225
Specifications
Max current draw: 7mA
Nominal operating voltage: 12 - 48V
Operating temperature: -22°F - 158°F
2
Once you have selected a centrally located
valve, remove the swivel tee and valve.
3
Replace with the sensor valve as shown. Use
care when helping the probe find its way into
the cell.
4
For EA-224 and EA-225, rotate clockwise to
lock the valve in place and reinstall swivel tee.
For EA-222 and EA-223, simply push-in the
valve until it snaps in to the battery.
If this is a new install, connect swivel tee to
the valve and connect tubing.)