  • Page 2: Table Of Contents

    Ultra-Temp ® TABLE OF CONTENTS Typical Installations ........................3-4 Technical Data Sheet ......................5-6 Chimney Lengths ........................7-9 Elbows and Tees ........................10-12 Supports ...........................13-17 Chimney Kits ........................18-19 Rain Caps/Storm Collar .....................20-21 Flashings ...........................22-23 Shields ..........................24-25 Adapters ..........................26 Accessories ........................27-29...
  • Page 3: Typical Installations

    Ultra-Temp ® Typical Installations 1. Masonry Fireplace using Selkirk Chimney Short or tall, large or small, there is a Selkirk Chimney System to suit every need or appliance. The following diagrams are intended as guides to proper part selection for several common chimney installations.
  • Page 4 Ultra-Temp ® Typical Installations continued 5. Combination of Furnace and 6. Wood Heater with its 4. Solid Fuel Appliance with a Water Heater on one chimney chimney through an short vertical chimney upstairs enclosure Round Top (T-CT) Round Top (T-CT) Round Top (T-CT) Storm Collar (T-SC) Storm Collar (T-SC)
  • Page 5: Technical Data Sheet

    Ultra-Temp ® ULTRA-TEMP /GALVA-TEMP All-Fuel Chimney ® ® TECHNICAL DATA SHEET IMPORTANT This catalog references ULTRA-TEMP/GALVA-TEMP Chimney Systems with maximum test temperatures under Underwriters’ Laboratories Safety Standard for Factory-Built Chimneys (UL -103). ® ULTRA-TEMP HT/GALVA-TEMP ULTRA-TEMP /GALVA-TEMP ® ® ® ®...
  • Page 6 Ultra-Temp ® ULTRA-TEMP /GALVA-TEMP All-Fuel Chimney ® ® CHIMNEY HEIGHT ABOVE ROOF Requirement #1: The chimney must extend not less than 3ft. above the highest point at which the chimney comes in contact with the roof Requirement #2: The chimney must extend not less than 2ft. above the highest roof surface or structure within a horizontal distance of 10ft. CHIMNEY HEIGHT CHART TO MEET THE 3, 2, 10 FOOT RULE ABOVE THE ROOF PITCH OF ROOF DISTANCE...
  • Page 7: Chimney Lengths

    Ultra-Temp ® Chimney Lengths CHIMNEY PARTS GUIDE The following section offers pictorial references, specifications and a brief description of major READ AND FOLLOW THE INSTALLATION INSTRUCTIONS WHEN components to aid in the design of an Ultra-Temp - Type HT, Galva-Temp - Type HT, Ultra-Temp and INSTALLING ANY CHIMNEY SYSTEM.
  • Page 8 Ultra-Temp ® Chimney Lengths INSULATED LENGTHS ULTRA-TEMP • Stainless steel inner and outer pipe. • All insulated pipe lengths are furnished with a Locking Band. • Secure twist-lock design couples chimney sections together with just a 1/8 turn. • To calculate installed length, subtract 1-1/4" per joint. •...
  • Page 9 Ultra-Temp ® Chimney Lengths continued • Stainless steel inner and outer pipe. INSULATED LENGTHS ULTRA-TEMP • All insulated pipe lengths are furnished with a Locking Band. CONTINUED • Secure twist-lock design couples chimney sections together with just a 1/8 turn. •...
  • Page 10: Elbows And Tees

    Ultra-Temp ® Elbows and Tees LOCKING BANDS • Versatile, simple device for increasing stability of a chimney. • Inward flanges around the band fit into grooves at chimney length joints. • Reinforces joints of chimney and prevents accidental uncoupling. • Locking Band is included with all insulated lengths, tees and elbow kits.
  • Page 11 Ultra-Temp ® Elbows and Tees continued 30° INSULATED ELBOW KIT ULTRA-TEMP Size Product No. Part No. Pack 4" 204211 5" 12-1/2" 6-1/4" 205211 5T-EL 30 KIT 6" 12-1/2" 6-1/4" 206211 6T-EL 30 KIT 7" 13-3/4" 7" 207211 7T-EL 30 KIT 8"...
  • Page 12 Ultra-Temp ® Elbows and Tees continued INSULATED TEE AND PLUG • Allows the horizontal connection of the chimney to the appliance. • Can be used on the interior or exterior of the building, in combination with a Wall Support Assembly. •...
  • Page 13: Supports

    Ultra-Temp ® Supports • An ideal support assembly for open cathedral ceiling installations. Fits ROOF SUPPORT PACKAGE all roof pitches and requires only simple framing. Mounts easily on to top of roof through opening that allows 2" clearance. Maximum length of chimney which can be suspended below is 20' supported. "...
  • Page 14 Ultra-Temp ® Supports continued HEAVY DUTY UNIVERSAL ROOF • The Universal Roof Brace Kit is designed to provide extra stability for BRACE KIT the chimney system above roof line, and is required when the chimney extends 5 feet or more above the roof. •...
  • Page 15 Ultra-Temp ® Supports continued UNIVERSAL WALL SUPPORT / • Designed to support up to 29' of ULTRA-TEMP Chimney in a wall installation above the tee or above an offset. It can also serve RESUPPORT ASSEMBLY as an intermediate support. • This universal design will work on 5", 6", 7" and 8" diameters. 2"...
  • Page 16 Ultra-Temp ® Supports continued TEE CAP RETAINER • The Universal Tee Cap Retainer secures the tee cap on the bottom side of an Insulated Tee. • It can adjust to fit all chimneys ranging from 5"-8" in diameter. Required when Insulated Tee is suspended below a Universal Wall Support or Universal Extended Wall Support.
  • Page 17 Ultra-Temp ® Supports continued ANCHOR PLATE • The Anchor Plate provides a secure attachment for the chimney to smoke chamber outlet on masonry fireplaces, reducing footing loads and speeding construction. • The Anchor Plate can be used for adapting the UT Chimney to a "Listed"...
  • Page 18: Chimney Kits

    Ultra-Temp ® Chimney Kits ROOF TERMINATION KIT (RTK) • Includes the basic components for a standard installation. Contents: CT, AF-6 & SC. Size Product No. Part No. Description Pack 6" 206600 6T-RTK Roof Termination Kit (2/12 - 6/12) 8" 208600 8T-RTK Roof Termination Kit (2/12 - 6/12) Ultra-Temp HT Chimney Kits...
  • Page 19 Ultra-Temp ® Chimney Kits continued PITCHED CEILING SUPPORT KIT (PCK) • For installation of a chimney in a cathedral or pitched ceiling such as standard A-Frame construction. • The Pitched Ceiling Support Kit provides all necessary parts for a complete installation with the exception of the required Insulated Pipe Lengths and Adjustable Flashing (AF).
  • Page 20: Rain Caps/Storm Collar

    Ultra-Temp ® Rain Caps/Storm Collar ROUND TOP • Part of the chimney system roof assembly, the Round Top is designed with a dome to exclude rain and leaves and a lower skirt to deflect wind ULTRA-TEMP Type HT for proper chimney draft. •...
  • Page 21 Ultra-Temp ® Rain Caps/Storm Collar continued • The Storm Collar is designed to fit on the round chimney pipe just above STORM COLLAR the roof flashing. < • The upper edge of the Storm Collar should be waterproofed with non- hardening silicone caulking to prevent any water from leaking between the Storm Collar and chimney pipe.
  • Page 22: Flashings

    Ultra-Temp ® Flashings ROOF FLASHING SELECTION CHART Flashings are used to seal the opening where the chimney penetrates the roof to divert rain and snow down from the roof and away from the chimney system. A series of adjustable flashings are available depending on your roof pitch.
  • Page 23 Ultra-Temp ® Flashings continued 12/12 To 24/12 Pitch ADJUSTABLE FLASHING CONTINUED SAFETY VENTS ON ALL FLASHINGS Size Product No. Part No. Pack 6" 8-1/8" 28-3/4" 40-3/4" 24" 206835 6TAF-24 7" 9-1/8" 31-1/4" 43-1/2" 24" 207835 7TAF-24 8" 10-1/8" 33-3/8" 45-3/8" 24"...
  • Page 24: Shields

    Ultra-Temp ® Shields ATTIC INSULATION SHIELD The Attic Insulation Shield is used wherever the chimney enters an open attic. A drop-down Joist Shield is included for use when the chimney is enclosed below the ceiling. Refer to instructions for full details.The Attic Insulation Shield acts as an insulation shield to keep blown in or blanket insulation from filling in any framed opening or contacting the chimney.
  • Page 25 Ultra-Temp ® Shields continued FIRESTOP JOIST SHIELD • Used in floor/ceiling penetrations other than those which include a ceiling support. (RADIATION DUST SHIELD) • Not required when passing through roof. Size Product No. Part No. Pack 4" 12" 8" 6-1/8" HT4FRS 5"...
  • Page 26: Adapters

    Ultra-Temp ® Adapters Dripless Stove Pipe Adapters Dripless Stove Pipe Adapters are used to connect single wall stove pipe to Ultra-Temp or Galva-Temp Systems. Dripless Stove Pipe Adapters are designed to slip inside single wall stove pipe to contain any creosote dripping down the chimney to inside the stove pipe.
  • Page 27: Accessories

    Ultra-Temp ® Accessories • The Wall Band is used along the wall to provide for 2 inch clearance WALL BAND and assure stability. • Required at 8 foot or closer intervals above the tee to stabilize the chimney. • Stainless steel construction. Size Product Code Part No.
  • Page 28 Ultra-Temp ® Accessories continued FINISHING COLLAR • The Finishing Collar fits over lower end of suspended insulated chimney pipe to provide finished appearance. • Used to attach T-DSAC or T-CPA Pipe Adapters to lower end of suspended chimney or end of chimney connected to an Insulated Tee. •...
  • Page 29 Ultra-Temp ® Accessories continued • Used to trim the ceiling, closing off the airspace around the pipe when TRIM PLATE SPACER the chimney is supported from above & extended down into the room. • Used to trim the wall when chimney passes through a non-combustible wall.
  • Page 30 Notes...
  • Page 31 Notes...
  • Page 32 Ultra-Temp ® For training, detailed product information, downloadable catalogs and installation instructions visit our website: selkirkcorp.com selkirkcorp.ca Selkirk USA Selkirk Canada 4460 44th Street SE, Suite F P.O. Box 526, Depot 1, Grand Rapids, MI 49512 Hamilton, ON, L8L 7X6 phone: 1.800.992.VENT (8368) phone: 1.888.SELKIRK (735.5475) email: info@selkirkcorp.com...

Table of Contents