Ser ver
Oper ating P
r oper t i es
Power Suppl y
Power Supply
System
Management
Ser ver
Oper ating P
r oper t i es
Operating
Properties
Power Suppl y
Š Dual 1600W (240V) 80 PLUS Platinum redundant power supply
AC Input:
Š 100-120V~/ 12A, 50-60Hz
Š 200-240V~/ 10A, 50-60Hz
DC Output:
Š Max 1000W/ 100-120V~
Š +12V/ 81.5A
Š +12Vsb/ 2.5A
Š - Max 1600W/ 200-240V or 240Vdc Input
Š +12V/ 133A
Š +12Vsb/ 2.5A
Š Aspeed® AST2600 management controller
Š GIGABYTE Management Console (AMI MegaRAC SP-X) web interface
Š Dashboard
Š HTML5 KVM
Š Sensor Monitor (Voltage, RPM, Temperature, CPU Status ...etc.)
Š Sensor Reading History Data
Š FRU Information
Š SEL Log in Linear Storage / Circular Storage Policy
Š Hardware Inventory
Š Fan Profile
Š System Firewall
Š Power Consumption
Š Power Control
Š LDAP / AD / RADIUS Support
Š Backup & Restore Configuration
Š Remote BIOS/BMC/CPLD Update
Š Event Log Filter
Š User Management
Š Media Redirection Settings
Š PAM Order Settings
Š SSL Settings
Š SMTP Settings
Operating temperature: 10°C to 35°C
Š
Operating humidity: 8%-80% (non-condensing)
Š
Non-operating temperature: -40°C to 60°C
Š
Non-operating humidity: 20%-95% (non-condensing)
Š