Page 1
UM2266 User manual STSW-L9177A Graphic user interface for EVAL-L9177A Introduction The present document describes the L9177A Graphical User Interface (GUI) that allows to initialize and control the EVAL-L9177A evaluation board by changing parameters through the SPI protocol, manage the parallel PWM input and read the output.
Graphical User Interface description UM2266 Graphical User Interface description The L9177A GUI is made up by ten fields: Figure 1. GUI interface description Com Port Setup: the COM port is automatically recognized once the GUI is launched and the microcontroller board is correctly connected to PC and correct firmware is present on it.
UM2266 Running procedure Running procedure The Start sequence is the following: connecting the microcontroller to the PC using a serial or USB to serial Cable launching the GUI. The COM port will be automatically recognized once you will launch the GUI if the microcontroller board is correctly connected to PC and correct firmware is present on it.
Labview driver installation guide UM2266 Labview driver installation guide The L9177A GUI can be used standalone without a Labview license, but installing the free Runtime Engine for Labview 2016, following the below link: http://www.ni.com/download/labview-run-time-engine-2016/6067/en/ and the VISA Runtime 16, following the below link: http://www.ni.com/download/ni-visa-run-time-engine-16.0/6188/en/ 6/14 DocID030871 Rev 2...
UM2266 How to load general purpose FW on SPC56M-Discovery How to load general purpose FW on SPC56M- Discovery To use the L9177A GUI the discovery board SPC56M-Discovery+ must be programmed with the dedicated Firmware (L9177A.elf). This is the procedure to program the SPC56M- Discovery+ using the ST toolchain based on SPC5-UDEDEBG Start UDE Visual Platform 4.8 If not yet done, create a New Workspace for SPC56M.
How to load general purpose FW on SPC56M-Discovery UM2266 Figure 3. UDE: workspace load UDE Visual Platform 4.7 will be refreshed and new functionalities will appear, then click on “Load Program” (or File/LoadProgramm) 8/14 DocID030871 Rev 2...
UM2266 How to load general purpose FW on SPC56M-Discovery Figure 4. UDE: main interface Browse the file L9177A and click “Open” In the next windows click on “Cancel” DocID030871 Rev 2 9/14...
How to load general purpose FW on SPC56M-Discovery UM2266 Figure 5. UDE:.elf file loading Then click on “Program All”. Figure 6. UDE: program loading on Flash The UDE Visual Platform 4.7 will start to load the program. 10/14 DocID030871 Rev 2...
UM2266 How to load general purpose FW on SPC56M-Discovery Figure 7. UDE: loading progress When the procedure is terminated click on “Exit” on all windows Figure 8. UDE: loading completed 10. When the procedure is terminated click on “Exit” on all windows and close UDE Visual Platform 4.7.
Page 12
How to load general purpose FW on SPC56M-Discovery UM2266 please refer to the documentation of the adapter. The cable has to be connected to the COM0 port of SPC56M-Discovery. 12/14 DocID030871 Rev 2...
UM2266 Revision history Revision history Table 1. Document revision history Date Revision Changes 10-Oct-2017 Initial release. 08-Mar-2018 Updated document title. DocID030871 Rev 2 13/14...
Page 14
IMPORTANT NOTICE – PLEASE READ CAREFULLY STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, enhancements, modifications, and improvements to ST products and/or to this document at any time without notice. Purchasers should obtain the latest relevant information on ST products before placing orders.