  • Page 1 ND 4600/ ND 5000 ADDRESSABLE DIMMER PACKS OPERATION MANUAL Page 1 of 9...
  • Page 2 The NSI ND 4600 and ND 5000 satellite dimmer packs are both fully user addressable allowing assignment of four of a possible one hundred twenty-eight control channels.
  • Page 3: Specifications

    Serial Control System: Input Voltage to Output Response Time: Control Isolation: +15 V DC Available to Controller: Dimensions (HxWxD): Weight: Mounting Spec. (from hole centers): SPECIFICATIONS ND 4600 Four 600 Watts 2400 Watts (4) chokes 160USEC. NSI"Microplex" 50 MSEC. 1200 Volt HV 400 MA 8"x9.5"x3.5"...
  • Page 4: Addressing

    109-112 113-116 117-120 121-124 125-128 IMPORTANT: All NSI dimmer packs are shipped from the factory addressed for channels 1 -4. Units must be readdressed (see chart above) before being capable of receiving any other channels. ADDRESSING 5/J2 6/J2 Page 4 of 9...
  • Page 5 This green LED (Light Emitting Diode) will light whenever the dimmer pack is receiving AC power and functioning properly. Both the ND 4600 and ND 5000 are equipped with safety circuit interruption devices to protect the units from becoming overloaded. The ND 4600 utilizes fusing while the ND 5000 features a resetable external circuit breaker as well as internal fusing.
  • Page 6 AC OUTPUT RECEPTACLES Dual standard AC outlet receptacles are provided for each channel of both the ND 4600 and ND 5000. These receptacles provide power to the lamps in your lighting system. The amount of power supplied to these outlets control the intensity of the lights they drive. Multiplexed signals received from your NSI controller are translated into power levels to achieve the desired light intensity.
  • Page 7: Operational Hints

    1) Always place your dimmer packs as close as possible to the lights they are powering. This will reduce the number of extension cords required to hook up your system. 2) Use a power outlet located as close as possible to an electrical service panel (fuse box). It is best if the power outlet is on a separate circuit breaker or fuse from your audio system.
  • Page 8 NSI CORPORATION LIMITED WARRANTY NSI Corporation warrants new electronics products to be free from defective materials and workmanship for a period of two (2) years from the date of purchase to the original owner when purchased from an authorized dealer. The purchaser is responsible for completing and mailing to NSI, within 15 days of purchase, the warranty registration card enclosed with each product.
  • Page 9: Troubleshooting

    TROUBLESHOOTING GUIDE SYMPTOM NO OUTPUT, LED INDICATORS SHOW STATUS OKAY NO POWER LIGHTS ALWAYS OFF LIGHTS ALWAYS ON LIGHTS AND LED INDICATORS ON DIMMER PACK FLICKER OR GLOW DIMLY. CAUTION: PLEASE DISCONNECT POWER BEFORE REMOVING COVER FOR SERVICE AS HIGH VOLTAGE IS OTHERWISE PRESENT CHANNEL FUSE LOCATION REPLACE WITH VALUES AS LISTED BELOW:...