Page 1
TECHNICAL DESCRIPTION SET-1240 8 Channel 4/6-wire xVDT Emulator This document 9040TDD1100 is a technical description of the SET-1240 xVDT Emulator card. Note Before you begin, complete the Software and Hardware installation procedures applicable to your application. Note The guidelines in this document are specific to the SET-1240. The other components in the system might not meet the same safety ratings.
Safety Guidelines Caution Do not operate the SET-1240 in a manner not specified in this document. Product misuse can result in a hazard. You can compromise the safety protection built into the product if the product is damaged in any way. If the product is damaged, return it for repair.
Page 3
6-wire or 4/5-wire xVDT emulation. The SET-1240 xVDT Emulator Card works with a wide excitation frequency range of 400 Hz to 10 kHz. The emulated A and B signals can be controlled separately. This allows the SET-1240 xVDT Emulator Card to emulate resolvers.
Page 4
Circuitry Functional Block Overview Note Diagram shows the channel specific signals for only one channel. xVDT Emulator Block Details Note Every channel has a separate xVDT Emulation Block. 4 of 10 www.smart-e-tech.com SET-1240 Technical Description Issue 13/04/2022...
Page 5
4/5-wire mode: CHx_B- to be used as signal output (in 5-wire CHx_B+/- applications either CHx_A- or CHx_B+ can be used for common/GND line). CHx_EXC+/- Excitation input No connection J1, J2 Connector Pin Assignments 5 of 10 www.smart-e-tech.com SET-1240 Technical Description Issue 13/04/2022...
Page 7
CH4_CTRL_A CH7_CTRL_B CH7_CTRL_A CH6_CTRL_B CH6_CTRL_A XJ2 Connector Pin Assignments Signal Description CHx_CNTL_A Controls the A signal generation CHx_CNTL_B Controls the B signal generation Ground connection No connection XJ2 Connector Signal Descriptions 7 of 10 www.smart-e-tech.com SET-1240 Technical Description Issue 13/04/2022...
Page 8
Description Instrument 0+ Input: RTI Excitation + Instrument 0- Input: RTI Excitation - Instrument 1+ Output: Test Signal AB+ Instrument 1- Output: Test Signal AB- No connection XJ3 Connector Signal Descriptions 8 of 10 www.smart-e-tech.com SET-1240 Technical Description Issue 13/04/2022...
Excitation Voltage Min. Common mode -45 VDC Excitation Voltage Max. RTI CNTL Voltage +10 V Min. RTI CNTL Voltage -10 V Excitation Frequency Recommended 400 Hz – 10 kHz Operation Range 9 of 10 www.smart-e-tech.com SET-1240 Technical Description Issue 13/04/2022...
Page 10
IEC 61076-101 Environmental Property Condition Value Comment Operating Humidity Relative, non- 10%-90% condensing Storage Humidity Relative, non- 5%-95% condensing Operating Temperature Forced-air cooling from 0°C-40°C chassis Storage Temperature -40°C-85°C Maximum Altitude 2000m 10 of 10 www.smart-e-tech.com SET-1240 Technical Description Issue 13/04/2022...