INTRODUCTION The AGfirst effluent irrigation control system is driven by a Crouzet Millennium Smart Logic controller which Controls the motors of the effluent system to provides protection for both the system and the environment.
Page 3
The kelco E30. A Kelco E30 is used as pump protection in sandy areas and has output for fault to stop the controller on over or under pressure and a priming function to open a solenoid valve to protect the pump from running dry, it requires 5 cores and typically a 7c+E .75 mm is suitable.
Page 4
flow switch fault delay timer fault delay to ignore the flow meter’s fault signal for a specified time. Pump Start Delay Delay timer to allow the stirrer to agitate the pond before starting the pump. Use VSD as pump switch the control cabinets operation to run either a VSD or DOL pump Force power to Kelco force power to the Kelco switch when the system is not in operation to enable programming Bypass remote timer...
Page 5
The outputs of our controller are voltage free referenced to the common terminal. The inputs of our controller are active high reference to the DC supply. The inputs info the AGfirst controller operate as follows: Pump start /stop (pulsed) triggered on diff up...