Fnirsi SG-004A Operating Manual

Fnirsi SG-004A Operating Manual

Multi-functional signal generator

Advertisement

SG-004A
OPERATING MANUAL
M ul ti- f u n ct io n al Sig na l Gen e rator

Advertisement

Table of Contents
loading

Summary of Contents for Fnirsi SG-004A

  • Page 1 SG-004A OPERATING MANUAL M ul ti- f u n ct io n al Sig na l Gen e rator...
  • Page 2: Table Of Contents

    CATALOG 1、 Safety Instructions 2、 Product Description 2.1 Specifications 2.2 Function Introduction 2.3 Interface Terminal 2.4 Power & Charge 3、 Button Panel Introduction 4、 Display & Signal Description 4.1 Switching Of Signal Types 4.2 mA Current Signal 4.3 V Voltage Signal 4.4 XMT Passive Current Signal 4.5 Hz Pulse Signal 4.6 mV Millivolt Signal...
  • Page 3: 1、 Safety Instructions

    �、 SAFETY INSTRUCTIONS Plug the meter into the PC,and turn it on.Wait for the PC to recognize the USB drive named "Bootloader" Dont use the instrument in a flammable and explosive environment Used batteries for instrument replacement and discarded instruments cannot be disposed of with household waste.Please handle in accordance with relevant national or local laws and regulations When there is any quality problem with the instrument or when there is a question...
  • Page 4: Interface Terminal

    【 Modbus Slave 】 : FNIRSI SG-004A can communicate with configuration software or PLC via RS485, set the instrument 【...
  • Page 5: 3、 Button Panel Introduction

    When the (IN-) port is an independent power supply, it can be called a (24V) port, and it forms an output port pair with the (COM) port The safety limit voltage of the input terminal cannot be greater than 30Vpp, and the over limit will damage the equipment NOTE!...
  • Page 6 【 3-key area 】 【 3-key area 】 【 Panel Display 】 【 RCVK 】 Up function key: When the key is white, it is to add value or select upward (when the output pulse is quantitative and the cursor is not in, it is the same as the programming mode).In the history curve interface, it is a quick right shift of 100.
  • Page 7: 4、 Display & Signal Description

    flashes, it means that the output signal is not connected or the output is close to zero 【 Output Circuit Voltage 】 : FNIRSI SG-004A can set current output no-load voltage.The purpose of 12V is to save power.Some devices require a 24V drive capability 【...
  • Page 8: Hz Pulse Signal

    【 4.4 】 XMT Passive Current Signal 【 Mode Switch 】 :When the main interface 【 FN 】 is white.Press 【 IN/OUT 】 to switch the display of actual value and engineering quantity of input/output 【 Output Range 】 : The limit range of passive current output can be set 【...
  • Page 9: Loop Detection

    displayed in the original quantity position.For output, the cycle is displayed at the original engineering position, and the unit is milliseconds.When the main interface 【 FN 】 is white, press 【 OUT 】 to switch between cycle and quantitative values, which are distinguished by cursors.
  • Page 10: Signal Conversion

    【 Mode switch 】 : When the main interface 【 FN 】 is white.Press 【 OUT 】 to switch the display position of output actual loop current value and engineering quantity 【 Activate independent 24V 】 : After this item is checked, the independent 24V power supply starts to output from the (24V) port (IN-) port and the (COM) port, and is not affected by input and output signal type switching 【...
  • Page 11: Program Output

    【 Parameter Settings 】 : (1) Input upper limit/input lower limit: the amplitude range of the input signal (2) Output upper limit/output lower limit: the amplitude range of the output signal (3) Overrun allowed: For example, 1-5V is converted into 4-20ma.If the user checks this option, when the input is oV, the output will follow to OmA.If the user does not check it, then the output is 4mA and the output is locked within the set range (4) Automatic operation:After checking this option, the signal conversion will be...
  • Page 12: Real-Time Curve

    【 5.5 】 Real-time Curve 【 Instructions 】 : When the main interface 【 FN 】 is red, press the right button 【 CURVE 】 to switch the interface with/without curve 【 Parameter Description 】 : (1) Turn on the output curve: turn on the following display curve of the output signal (Red line) (2) Automatic output scaling: automatically adjust the scale range of the output signal, and automatically adjust the scale range of the y-axis with the maximum...
  • Page 13 �、 WIRING INSTRUCTIONS PLC/Process instrument, etc. 【 All switched by electronic switches 】 【 All-round Signal Output 】 : Current/Voltage/Millivolt/Frequency /Resistance/Thermal Resistance/ Various Thermocouple Signals PLC/Process instrument, etc. 【 All switched by electronic switches 】 【 All-round Signal Output 】 : Current/Voltage/Millivolt/Frequency /Resistance/Thermal Resistance/ Various Thermocouple Signals...
  • Page 14 【 7.3 】 Firmware Upgrade SG-004A uses USB emulated U disk for firmware upgrade. 【 Upgrade Steps 】 : (1) Plug the meter into the PC,and turn it on.Wait for the PC to recognize the USB drive named "Bootloader"...
  • Page 15 �、 PRODUCTION INFORMATION Product name: Multi-functional Signal Generator Brand / Model: FNIRSI / SG-004A Manufacturer: Shenzhen FNIRSI Technology Co., Ltd. Website: www.fnirsi.cn Address: Building C, Weihuada Industrial Park, Dalang Street, Longhua District, Shenzhen, Guangdong, China PAGE ��...
  • Page 16 Function code Hexadecimal Type of data Attributes 0x64 uint16_t read 0x65 uint16_t write 0x66 float read 0x67 float write 【 Schedule 1 】 Address Hexadecimal Type of data Attributes Illustrate 40001 0X9C41 uint16_t read Firmware version 40002 0X9C42 uint16_t Input signal 40003 0X9C43 uint16_t...
  • Page 17 Download Manuals and Firmware Manufacturer: Shenzhen FNIRSI Technology Co., Ltd. Website: www.fnirsi.cn Address: Building C, Weihuada Industrial Park, Dalang Street, Longhua District,Shenzhen, Guangdong, China...