Summary of Contents for Minebea Intec PR 5110/60

  • Page 1 All manuals and user guides at all-guides.com Instrument manual Remote display PR 5110/60, ../70 Translation of the original instrument manual 9499 050 51600 Edition 3.1.0 02/07/2019 Release 1.00 Minebea Intec GmbH, Meiendorfer Str. 205 A, 22145 Hamburg, Germany Phone: +49.40.67960.303 Fax: +49.40.67960.383...
  • Page 2 Any information in this document is subject to change without notice and does not represent a commitment on the part of Minebea Intec unless legally prescribed. This product should be operated/installed only by trained and qualiied personnel. In correspondence concerning this product, the type, name, and release number/serial number as well as all license numbers relating to the product have to be cited.
  • Page 3: Table Of Contents

    All manuals and user guides at all-guides.com Remote display PR 5110/60, ../70 Table of contents Table of contents Introduction............................3 Read the manual................................. 3 This is what operating instructions look like ......................3 This is what lists look like............................3 This is what menu items and softkeys look like.....................
  • Page 4 All manuals and user guides at all-guides.com Remote display PR 5110/60, ../70 Table of contents Getting started ...........................21 LOCK switch/power failure ............................21 5.1.1 Control cabinet housing..........................21 5.1.2 Table-top housing ............................22 Switching on the device............................22 5.2.1 Automatic tests ..............................22 5.2.2 Test menu................................ 23 Device coniguration..............................
  • Page 5: Introduction

    All manuals and user guides at all-guides.com 1 Introduction Remote display PR 5110/60, ../70 Introduction Read the manual Please read this manual carefully and completely before using the product. This manual is part of the product. Keep it in a safe and easily accessible location.
  • Page 6: Hotline

    All manuals and user guides at all-guides.com Remote display PR 5110/60, ../70 1 Introduction NOTICE Warning of damage to property and/or the environment. NOTICE indicates that damage to property and/or the environment may occur if appropriate safety measures are not observed.
  • Page 7: Safety Instructions

    The unit is approved for operation in legal-for-trade applications. The remote displays PR 5110/60, ../70 are suitable for use in zones 1 (PR 5110/60, ../70) and 21 (only PR 5110/70). The instruments are itted with an intrinsically safe serial interface.
  • Page 8: Installation

    Supply voltage connection Control cabinet Table-top housing housing The remote display PR 5110/60, ../70 has a 12 V intrinsically safe feed. The intrinsically safe feed can, forexample, be realized by a safety barrier or an intrin- sically fed power supply.
  • Page 9: Rf Interference Suppression

    General information Repairs are subject to inspection and must be carried out at Minebea Intec. In case of defect or malfunction, please contact your local Minebea Intec dealer or service center for repair. When returning the device for repair, please include a precise and complete description of the problem.
  • Page 10: Remote Display

    All manuals and user guides at all-guides.com Remote display PR 5110/60, ../70 3 Remote display Remote display General notes The instrument is equipped with a 7‑digit 7‑segment display. Weight values with max. 6 digits and an additional 14‑segment display, mass unit, status display and optional framing of the last digit can be displayed.
  • Page 11: Housing

    Remote display PR 5110/60, ../70 Housing 3.3.1 General notes The following housing options are available: Aluminum with IP65 front for switchbox installation (PR 5110/60) Stainless steel IP65 for table or wall mounting (PR 5110/70) 3.3.2 Dimensions 3.3.2.1 Control cabinet housing The keypad and the display form one unit with the front.
  • Page 12 All manuals and user guides at all-guides.com Remote display PR 5110/60, ../70 3 Remote display 3.3.2.1.1 control panel cut-out 187 +0.5 x 91 +0.5 All dimensions in mm 3.3.2.2 Table-top housing The keypad and the display form one unit with the front. The cables are fed through entry glands on the bottom of the housing and connected to the electronics.
  • Page 13 All manuals and user guides at all-guides.com 3 Remote display Remote display PR 5110/60, ../70 3.3.2.2.1 Support bracket The remote display with table-top housing has a support bracket with drilled holes at various intervals. The table-top housing is secured in the desired position using handwheel bolts (not shown).
  • Page 14: Display And Operating Elements

    All manuals and user guides at all-guides.com Remote display PR 5110/60, ../70 3 Remote display Display and operating elements 3.4.1 Instrument display 7‑digit weight values (digit height 18 mm) with the decimal points can be shown on the display. The available mass units are t, kg, g, or lb.
  • Page 15: Operation Using The Front-Panel Keys

    All manuals and user guides at all-guides.com 3 Remote display Remote display PR 5110/60, ../70 Symbols/mass unit Description In the W&M mode, an invalid weight will be display- ed without a weight unit. e.g.: 10-fold resolution, -20 d t, kg, g, lb These mass units are available.
  • Page 16 All manuals and user guides at all-guides.com Remote display PR 5110/60, ../70 3 Remote display Navigation/Menu Keys Next digit value/selection Instrument settings, set-up Previous digit value/selection Select weighing point Cursor to the left Exit Exit from current menu, continue operation at next higher level.
  • Page 17: Device Installation

    All manuals and user guides at all-guides.com 4 Device installation Remote display PR 5110/60, ../70 4 Device installation General notes Before starting work, please read Chapter 2 and follow all instructions. WARNING Warning of hazardous area and/or personal injury All cable connections must be protected from damage.
  • Page 18: Installation Of A Cable In The D-Sub Connector

    All manuals and user guides at all-guides.com Remote display PR 5110/60, ../70 4 Device installation Reinstall the anchoring clamps on the sides of the housing. Do not overtighten the screws! Secure the cable at the place of installation, e.g. using cable ties.
  • Page 19: Cable Gland

    All manuals and user guides at all-guides.com 4 Device installation Remote display PR 5110/60, ../70 4. Cut back the cable screen (3) up to 5 mm and bend back over the cable mantel (1). 5. Remove the insulation of the cable strands 3 mm and solder.
  • Page 20: 4.4 Hardware Construction

    All manuals and user guides at all-guides.com Remote display PR 5110/60, ../70 4 Device installation 3. Guide the cable (5) through the gland (6). 4. Fold the cable shield (4) over the lower part of the terminal insert (3) (approx. 10 mm).
  • Page 21 All manuals and user guides at all-guides.com 4 Device installation Remote display PR 5110/60, ../70 Description Data Parity even Signal high 18…22 mA Signal low 0…1 mA Number of signals Potential isolation Cable type Screened twisted pair (suchas LifYCY 3×2×0.20) Cable gauge 0.25…0.5 mm...
  • Page 22 All manuals and user guides at all-guides.com Remote display PR 5110/60, ../70 4 Device installation 4.4.1.1 Connection to relay PR 1625/60 ① Ex-zone ② no ex-zone (secure area) ③ Potential equalization line Coniguration PR 5110 for PR 5220, PR 5230,...
  • Page 23: Getting Started

    All manuals and user guides at all-guides.com 5 Getting started Remote display PR 5110/60, ../70 Getting started LOCK switch/power failure All coniguration parameters are iled in a non-volatile storage medium (EAROM). There is an additional write protection (LOCK switch). If the grid power fails, all entered parameters are saved.
  • Page 24: Switching On The Device

    All manuals and user guides at all-guides.com Remote display PR 5110/60, ../70 5 Getting started 5.1.2 Table-top housing The LOCK switch is located on the mainboard. + 12 V= – PE Com 1 LOCK Function Switch setting closed open Switching on the device Before switching on the remote display for the irst time, the installation must be complete.
  • Page 25: Test Menu

    All manuals and user guides at all-guides.com 5 Getting started Remote display PR 5110/60, ../70 If the transmitter or remote indication has not yet been correctly set and adjusted, the remote display dashes. - - - - - 5.2.2 Test menu...
  • Page 26 All manuals and user guides at all-guides.com Remote display PR 5110/60, ../70 5 Getting started After coniguration, set the LOCK switch into the closed position , in order to protect the parameters against accidental alteration and power failure. 5.3.1.1 Selecting a digit position...
  • Page 27: Procedure

    All manuals and user guides at all-guides.com 5 Getting started Remote display PR 5110/60, ../70 5.3.2 Procedure * (Factory Settings) default ** An invalid weight is displayed without a mass unit. EN-25 Minebea Intec...
  • Page 28 All manuals and user guides at all-guides.com Remote display PR 5110/60, ../70 5 Getting started oP 010 Line – curloop: Interface COM 1 TTY Current loop oP 011 Transfer rate oP 012 Token – of: one remote display on one indicator Token –...
  • Page 29: Maintenance/Repairs/Soldering Work/Cleaning

    Repairs Repairs are subject to inspection and must be carried out at Minebea Intec. In case of defect or malfunction, please contact your local Minebea Intec dealer or service center for repair. When returning the device for repair, please include a precise and complete description of the problem.
  • Page 30: Disposal

    All manuals and user guides at all-guides.com Remote display PR 5110/60, ../70 7 Disposal Disposal If the packaging is no longer required, please take it to your local waste disposal facility and/or a reputable disposal company or collection point. The packaging largely consists of environmentally friendly materials which can be used as secondary raw materials.
  • Page 31: Technical Data

    Location no.: Code for the year/month: Current number 30 = Hamburg 252* = April 2010 * Is increment according to the year group table of Minebea Intec. Possible marking for the Ex area Zone Marking Certiicate no. II 2 G Ex ib IIC T6 / T5 Gb...
  • Page 32: General Data

    All manuals and user guides at all-guides.com Remote display PR 5110/60, ../70 8 Technical data General data 8.4.1 Supply voltage connection Supply voltage 12 VDC Rated operating range 10 to 12.6 V Power consumption typ. 0.22 W max. 0.53 W...
  • Page 33: Interference Suppression

    All manuals and user guides at all-guides.com 8 Technical data Remote display PR 5110/60, ../70 Signal and control Fast transients (burst) EN 61000-4-4 2 kV lines Peak voltages (surge) 1.2/50 µs* EN 61000-4-5 1 kV Conducted disturbances by high fre-...
  • Page 34: Appendix

    Remote display PR 5110/60, ../70 9 Appendix Appendix Certiicates/technical documents Ser. no. Description Document no. EC-Declaration of Conformity MEU17055 EC-Type Examination Certiicate KEMA 10 ATEX 0090X The documents listed in the table can be found on the PR 5110/60, ../70 CD. Minebea Intec EN-32...
  • Page 35 All manuals and user guides at all-guides.com...
  • Page 36 All manuals and user guides at all-guides.com Published by Minebea Intec GmbH | Meiendorfer Strasse 205 A | 22145 Hamburg, Germany Phone: +49.40.67960.303 | Email: info@minebea-intec.com www.minebea-intec.com...

This manual is also suitable for:

Pr 5110/70

Table of Contents