Single And Dual Acting Hyd. Power Unit Installation - Primary Mover PH310 Operator's Manual And Installation Instructions

Power hoist
Table of Contents

Advertisement

SINGLE AND DUAL ACTING HYD. POWER UNIT INSTALLATION

If included with the kit, mount HPU (hydraulic power unit) in a weather tight enclosure
on the trailer. See additional instructions supplied with the HPU for mounting, electrical,
wireless remote and hydraulic fluid requirements.
CAUTION Hydraulic components that are not provided by Primary Mover and
!
are used in the hydraulic circuit that are incompatible with Primary Mover components
may cause damage to, or failure or malfunction of, the direct push cylinder or other
components of the Primary Mover product(s). Such damage, failure or malfunction may
cause property damage, personal injury or even death, It is the purchaser's
responsibility to verify the compatibility of components not provided by Primary Mover.
W ARNING
!
Connecting the jack to a hydraulic system with more
pressure (PSI) or flow (GPM) than is recommended by Primary Mover could cause the
jack to fail during operation. Such failure could cause property damage, personal injury,
or even death. Ensure that you have pressure that does not exceed tolerances and
limits stated for your Primary Mover product(s)/component(s), and that there is no
restriction or issue concerning flow before operation. Consult Primary Mover if you are
unsure about the limits, capacities and/or tolerances of your hydraulic system.
WARNING
!
Adjusting the hydraulic pressure to exceed the recommended
limits or setting could cause the jack to fail during operation. Such failure could cause
property damage, personal injury, or death. Pressure should ONLY be adjusted by a
trained and qualified technician or mechanic, and should never exceed stated limits or
settings of components used.
Hydraulic System Pre-Operation
The hydraulic system supplied by Primary Mover consists of components (pump,
valves, reservoir, hoses, cylinder, etc.) that are designed to be compatible with each
other.
All Primary Mover's liability and warranty will be voided if determined by Primary
Mover that substituted hydraulic components (i.e., hydraulic components not provided
by Primary Mover as part of the kit) were used and such components were
incompatible with components of the kit provided by Primary Mover. Hydraulic
parameters are shown below. These are listed as a general
guide to ensure proper compatibility (when using other hydraulic components). If you
have any questions about component compatibility, please contact Primary Mover
before installation, use or maintenance.
Maximum Working Pressure---3200 PSI
Hydraulic Port Type--#6 JIC
Primary Mover
Mandeville, Louisiana
Page 15

Advertisement