Mecasys Co., Ltd. Notice: Spectrophotometer Optizen® is a registered trademark of Mecasys Co., Ltd. No part of the Optizen Series, including this publication may be reproduced, or modified in any form or by any means without the prior permission of Mecasys Co., Ltd.
OPTIZEN 1412V User‟s Guide Contents ------------------------------------------------------------------------------------------------ Part 1 Introduction & General Information … 4 I. Introduction … 5 1. SYSTEMS Optical System Sample Compartment Modes Electronics Dimension Print Real-time PC Software (OptizenView) … 7 2. Constructions Exterior View Front Side...
By utilizing a holographic grating system, Optizen 1412V can produce and select 760 single wavelengths from 340nm to 1100nm at 1nm intervals. Free voltage system allows connecting with any normal AC input source.
OPTIZEN 1412V User‟s Guide Rear Side Rs-232c Power Switch Cooling Fan Power Cord Receptacle 전원연결부 부 Left Side Door for replacing ROM and A/S Right Side - 8 -...
15~30 minutes for the stability of measurement. 2. Main Screen Form (Measure Mode) OPTIZEN 1412V An initial screen of Optizen 1412V is shown as left picture. Select mode you want by 1. STC Mode inputting the number of it. 2. ABS/%T Mode 3.
OPTIZEN 1412V User‟s Guide III. Usage of each MODE 1. STC Mode (Standard Curve Mode) STC Mode This is measuring mode by user-made and 1. EMPTY saved standard curves. It is all EMPTY in 2. EMPTY 3. EMPTY factory mode (initial state). You can save 4.
Page 12
OPTIZEN 1412V User‟s Guide STC Mode Input STC name with reference to string table under Cell Compartment Cover. Input STC Name. You can be helped by Input method of the Appendix. –– STC Mode Input the measure Wavelength and press [ENTER].
Page 13
OPTIZEN 1412V User‟s Guide You can choose the decimal places of the STC Mode result. If you input [3], you can see the results Decimal ? down to three decimal places. (Maximum down to three decimal places) Choose Make STC or use previous STC Mode factor that you already know.
Page 14
OPTIZEN 1412V User‟s Guide Check the inputted value and insert the Mode very standard solution into Cell holder. And press [ENTER] to measure. Conc.1 = 0.250 Insert Conc. 1, Press [ENTER] Check the measured absorbance value of Mode the first standard solution. If you want to measure the second standard solution, Conc.1...
Page 15
OPTIZEN 1412V User‟s Guide In case of choosing ‘N’ at Make STC (Y/N)? Mode As you select to use previous STC factor y=aX^2 + bX + c that you already know instead of making y=Conc. X=ABS the new STC, you can see the screen as left.
Page 16
OPTIZEN 1412V User‟s Guide DELETE STC This mode is to delete the existing STC formula. Input the saved code number and press [ENTER]. And you can see the second screen. Delete STC Delete STC Name: DELETE CODE # AABBCC Delete (Y/N)?
OPTIZEN 1412V User‟s Guide 2. ABS/%T Mode ABS / % T MODE Without concerning with specific parameter, you can measure the simple absorbance and transmittance on specified wavelength. Input W.L.(nm) ____ Input Wavelength and press [ENTER] to measure. 3. P/C Connect...
OPTIZEN 1412V User‟s Guide IV. Measurement Procedure 1. STC Mode Select 1. STC Mode at initial Menu. OPTIZEN 1412V 1. STC Mode 2. ABS/%T Mode 3. P/C Connect 4. Open Data Select #( 1 ~ 4) Mode Select a measure item by input the number.
Page 19
OPTIZEN 1412V User‟s Guide Mode Insert the measure sample into Cell holder, and press [ENTER] key to measure. If you Insert Sample measure the same items successively, you Press [ENTER] can keep measuring without Blank check by press [ENTER] key.
Page 20
OPTIZEN 1412V User‟s Guide Use Up, Down Key to scroll and see the STC Result whole data. CONC. 1)12.112 2.12 2)12.112 2.21 3)13.252 2.21 [ENTER]: Save as files. 4)12.121 2.21 [ESC]: Move previous menu 5)12.121 2.21 without saving. E N T E R Save [↑...
OPTIZEN 1412V User‟s Guide 2. ABS/%T Mode OPTIZEN 1412V In case of selecting [2] ABS/%T Mode to measure. 1. STC Mode 2. ABS/%T Mode 3. P/C Connect 4. View Data Select # (1~4) Press [ENTER] after measure Wavelength. ABS / %T Mode...
Page 22
OPTIZEN 1412V User‟s Guide Insert a sample into Cell holder, and press ABS / %T Mode [ENTER] key to measure. If you measure the same items successively, you can keep measuring without Blank check by press 0.256 ABS [ENTER] key. On or after measuring, you 89.314...
OPTIZEN 1412V User‟s Guide Part 3. Technical Supports Technical Supports & A/S If you come across any problem while installing or using Optizen 1412V, please refer to this manual first. If you are still unable to find a solution of the problem, please contact us via telephone, fax, e- mail and our websites.