Installation Note
Agilent N9039A RF Preselector
Option BAB, 3.5 mm RF Connectors
Option 518, Type-N RF Connectors
Part Number N9039-90004
Printed in USA December 2008

Advertisement

loading

Summary of Contents for Agilent Technologies N9039A

  • Page 1 Installation Note Agilent N9039A RF Preselector Option BAB, 3.5 mm RF Connectors Option 518, Type-N RF Connectors Part Number N9039-90004 Printed in USA December 2008...
  • Page 2 The information contained in this document is subject to change without notice. Agilent Technologies makes no warranty of any kind with regard to this material, including but not limited to, the implied warranties of merchantability and fitness for a particular purpose.
  • Page 3 Option BAB, 3.5 mm RF Connectors Option 518, Type-N RF Connectors Installation Kit Option BAB, 3.5 mm RF Connectors Option 518, Type-N RF Connectors Installation Kit Products Affected: N9039A Serial Numbers: To Be Performed By: (X) Agilent Service Center (X) Personnel Qualified by Agilent...
  • Page 4 Introduction This kit contains all of the instructions and parts required to install Option BAB or Option 518 on an Agilent N9039A RF Preselector. This installation note provides instructions on how to change the RF INPUT and RF OUTPUT front panel connectors.
  • Page 5 N9039-60028 RF Output Connector Assembly N9039-60030 Tools Required ❏ N9039A RF Preselector Service Guide. This manual can be purchased as N9039A-0BW or N9039-90002. ❏ Personal computer with internet access and USB port ❏ T-20 TORX driver ❏ T-10 TORX driver ❏...
  • Page 6: Installation Procedure

    Option BAB, 3.5 mm RF Connectors Option 518, Type-N RF Connectors Installation Kit Installation Procedure If the instrument is placed on its face during any of the following CAUTION procedures, be sure to use a soft surface or soft cloth to avoid damage to the front panel, keys, or input connector.
  • Page 7 Option BAB, 3.5 mm RF Connectors Option 518, Type-N RF Connectors Installation Kit NOTE Make sure any connectors on the front panel are removed. 5. Refer to Figure 2. Using the T-10 driver, remove the eight screws (1), four on each side, to detach the Front Frame Assembly from the chassis.
  • Page 8 Option BAB, 3.5 mm RF Connectors Option 518, Type-N RF Connectors Installation Kit 7. Refer to Figure 4. Loosen the three semi-rigid cables from the three front panel connectors. Figure 4 Front Panel Connector Semi-Rigid Cables Installation Note N9039-90004...
  • Page 9 Option BAB, 3.5 mm RF Connectors Option 518, Type-N RF Connectors Installation Kit 8. Refer to Figure 5. Remove the chassis side right (outer) (1) by removing the screws (2) using the T-10 driver. Figure 5 RF Side Chassis Removal 9.
  • Page 10 Option BAB, 3.5 mm RF Connectors Option 518, Type-N RF Connectors Installation Kit 16.Refer to Figure 2. Carefully position the Front Frame Assembly onto the chassis. Ensure no cables are crushed. Replace the eight screws (1), four on each side of the chassis.
  • Page 11 Option BAB, 3.5 mm RF Connectors Option 518, Type-N RF Connectors Installation Kit Installation of N9039AK-BAB License For installing Option BAB. 1. Locate the Option Upgrade Entitlement Certificate (5964-5178) from the kit. 2. Redeem the Option Upgrade Entitlement Certificate by following the instructions on the Certificate.
  • Page 12 Option BAB, 3.5 mm RF Connectors Option 518, Type-N RF Connectors Installation Kit Figure 7 Successful License Installation Alternate Installation Procedure The License File can be manually installed over USB or LAN by placing the license file in the following folder on the signal analyzer C:\Program Files\Agilent\licensing Verify the Installation of Option BAB 1.
  • Page 13 System Licensing BAB and press Delete Alternate Removal Procedure The License File can be manually deleted by removing the N9039A file from the following folder on the N9039A RF Preselector: C:\Program Files\Agilent\licensing Verify the Installation of Option 518 1. Press to display a list of installed options.
  • Page 14 For assistance, contact your nearest Agilent Technologies Sales and Service Office. To find your local Agilent office access the following URL, or if in the United States, call the following telephone number: http://www.agilent.com/find/assist...