______________________________________________________________________________________ Operating Instructions ExactSonic P Software status from 1.1.0.220325 Ultrasonic Massflow Measuring System for exact mass flow measurement U447_ExactSonicP_B_e_220628 1/18...
Tab Control ........................8 Tab Settings ........................9 Tab Info ......................... 11 Status LED ........................11 4 TCP Interface .......................... 12 Communication between evaluation unit and ExactSonic P ........... 12 Interface Specification ..................... 12 Security ......................... 12 Protocol Description ......................12 4.4.1 Command - Telegram ...................
______________________________________________________________________________________ 1 Safety Instructions Danger to life, risk of injury and damage to material or property. Read the Operating Instructions carefully before initial operation. Observe general safety precautions as well as those included in various sections of these Operating Instructions Hazard risks: non-observance of the Operating and Safety Instructions modifications to the device by the customer...
Year of production, protection class Manufacturer Scope of Delivery Gas mass flow measuring system - ExactSonic P Operating Instructions ExactSonic P Please check that everything listed in the Delivery Note / Technical Data Sheet is included in the delivery. Technical Specifications 1.4.1...
______________________________________________________________________________________ 1.4.2 Housing and Connection Dimensions : 240 / 160 / 134 mm (L / B / H) Housing material : aluminium, powder coated Connections : 3-pole socket for connection of supply voltage 5-pole socket for connection of analog output RJ45 socket for TCP communication USB socket for Backup/Restore 1.4.3...
______________________________________________________________________________________ 2 Initial Operation of the Measuring Device For the installation and operation of the measuring system, the applicable national regulations for the in- stallation and operation of electrical systems, as well as the general rules of technology and these operat- ing instructions are decisive.
______________________________________________________________________________________ 3 User Interface The user interface consists of an illuminated 7" touch display, which is embedded in the housing. After starting, the tab graph is displayed. At the top, you can switch to the respective tab by tapping on the corresponding tab.
______________________________________________________________________________________ Tab Control Task: Starting and stopping the measuring function, resetting the quantity counter, restarting and shutting down the unit. In Tab Control the measurement can be paused. The graph is no longer updated when the measurement function is stopped; the last measured value is permanently displayed. The measurement data via TCP interface also no longer change, the last measured values are always transmitted.
______________________________________________________________________________________ Tab Settings Task: Displaying and changing device parameters. In Tab Settings, the following settings of the device can be changed: Device description The device designation is a freely selectable name with a length of 15 characters for designating the measuring point.
Page 10
______________________________________________________________________________________ TCP port Port address for TCP interface. A restart of the unit is required to apply the change. Analog out - Start value Start value of the analog output in the set unit. The start value must be smaller than the end value, otherwise the value at the analog output is invalid.
The device's time is set automatically when there is an internet connection. If the network in which the ExactSonic P is integrated does not have access to the Internet or the device has no authorization, the date and time can be set using the AK protocol (see AK command „ESYT“ in chapter 4.4.5).
The communication between the evaluation unit and the ExactSonic P takes place via TCP via the built-in RJ45 socket. In this communication, the master is the evaluation unit, the ExactSonic P is the slave. The master sends a command, whereupon the slave responds accordingly. The protocol, which is referred to here as the AK protocol, was implemented according to the VDA standards of the "Standardisation of Ex-...
______________________________________________________________________________________ 4.4.1 Command - Telegram Character Details 1. Byte ASCII Code 02 2. Byte BLANK any ASCII character, blank preferred 3. Byte FUNCTION CODE 1 1. character of the AK command e.g. A of ABCD 4. Byte FUNCTION CODE 2 2.
AK commands – Query Commands (reading only) Code Channel Description Data format AKEN device description string "ExactSonic P" ALMT last maintenance time integer value in hours. operating time of the device, on which the last maintenance of the device was performed. AMFR...
______________________________________________________________________________________ AVER device version integer value main version integer value minor version integer value patch level integer value build number each separated by dot, e.g. "1.1.25.103" 4.4.5 AK Commands – Setting Commands Code Channel Description Data format EAOA startin value analog output float value, unit see EDUN e.g.
______________________________________________________________________________________ ESYT system time year, month, day, hour, minute, second in format "yyyy.MM.dd HH:mm:ss" (HH = 24h) e.g. "2019.07.15 16:37:00" Only for devices that do not have an internet connection. ETCP TCP address IP address in standard notation e.g. "192.168.0.1" - default "192.168.137.69" restart necessary after change EVHI influence humidity value...
______________________________________________________________________________________ 5 Troubleshooting Error Reason Troubleshooting Device shows no Power supply insufficient Check power supply and connector function Elektronics defective Return to the factory No measured value Sensor dirty Check and clean the sensor Incorrect measurement Comparison and correction of the settings ac- settings cording to the specifications in the Technical Data Sheet...
Höntzsch GmbH & Co KG Gottlieb-Daimler-Str. 37 D-71334 Waiblingen bearing sole responsibility, hereby declare that the product ExactSonic P Ultrasonci Massflow Measuring System referred to in this declaration, is in conformity with the following standards or normative docu-ments: Provisions of the Directive...
Need help?
Do you have a question about the ExactSonic P and is the answer not in the manual?
Questions and answers