Advertisement

Quick Links

victron energie
USER MANUAL
GEBRUIKSAANWIJZING
GEBRAUCHSANWEISUNG
Victron Atlas Combi 12/800
victron energie

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Atlas Combi 12/800 and is the answer not in the manual?

Questions and answers

Summary of Contents for Victron Energie Atlas Combi 12/800

  • Page 1 USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas Combi 12/800 victron energie...
  • Page 2 Subject to change without notice AC04001E / 271095 victron energie user manual...
  • Page 3 SECTIONS ENGLISH NEDERLANDS DEUTSCH victron energie user manual...
  • Page 4 manual...
  • Page 5 ENGLISH USER MANUAL Victron Atlas Combi 12/800 victron energie user manual...
  • Page 6 manual...
  • Page 7 Our equipment is suitable for countless situations in the field, on ships or other places where a mobile 230-Volt AC power supply is indispensable. Victron Energie has the ideal power source for all kinds of electrical appliances used for household, technical and administrative purposes, including instruments susceptible to interference.
  • Page 8 manual...
  • Page 9: Table Of Contents

    4.4.3 230 V input 4.4.4 Battery 4.5 Starter battery 4.6 Jumpers, general 4.7 Potentiometers, general START-UP 5.1 Operation 5.2 “On” position 5.3 “Auto” position 5.4 Changeover 5.4.1 Engaging 230 V mains 5.4.2 Disengaging 230 V mains 5.5 Charger victron energie user manual...
  • Page 10 7.1.3 Automatic Economy Switch (AES) 7.2 Battery charger 7.2.1 Input 7.2.2 Output 7.2.3 Changeover 7.3 General 7.4 Mechanical data DRAWINGS Complete energy system Atlas Combi cabinet dimensions Remote control connections Atlas Combi connections Position jumpers Atlas Combi victron energie user manual...
  • Page 11: Description

    DESCRIPTION General Victron Atlas Combi 12/800 units are tested to ensure correct functioning before leaving the factory. They are packed in shock-absorbing polystyrene and packed in sturdy cardboard boxes for secure transportation. The Victron Atlas Combi is housed in a robust aluminium cabinet (IP21) suitable for floor or wall mounting.
  • Page 12: The Battery Charging Section

    Substantially reduced power Printed Circuit consumption is achieved when there are intermittent loads. Board The sensitivity of the AES (Automatic Economy Switch) can be adjusted, for more information see section 5 “Start-up”. victron energie user manual...
  • Page 13: Changeover

    = a load regularly about this changeover is switched on and given in section 5.4. off automatically in equipment such as refrigerators or Illustration 2. No load output voltage electric heaters during “auto” mode. with thermostats. victron energie user manual...
  • Page 14: Charging

    12 V (see section 1.3). The standard settings for boost Direct Current. charging voltage and float charging voltage are 14.25 V and 13.5 V respectively. 12 Vdc 14,25 13,5 time 30 sec. 4 hours boost equalize boost equalize float time victron energie user manual...
  • Page 15: Protective Devices

    Descriptions of these devices are given below. Short-circuits With the Atlas Combi 12/800, inverter output (which is protected against short-circuiting) amounts to 2.75 amp. In this condition the output voltage approaches 0 V. Once the short-circuit has been rectified the inverter immediately short circuit resumes normal operation.
  • Page 16: Temperature

    17.3 V and restarts once the input voltage has dropped below ±16.3 V. The Atlas Combi 12/800 is NOT protected against reversed polarity (i.e. “+” connected to “-” and “-” connected to “+”). Accordingly, please follow carefully the instructions which are given in section 4.3.
  • Page 17: Compensated Charging

    In this temperature range, the output voltage is dependent on battery temperature (as measured by the sensor). As the temperature increases, the output voltage of the charger decreases by 30 mV/°C (5 mV/°C per cell). (See illustration 4, section “B”). victron energie user manual...
  • Page 18: High Battery Temperature

    ( C) It is also necessary to change jumper HRD6 Illustration 4. Temperature com- on the control PCB (see section “Drawings”, pensation while loading. drawing number AC04013E, page 42) victron energie user manual...
  • Page 19: Installation

    1.5 m 25 mm more than 2.5 m but less than 4.0 m 35 mm more than 4.0 m but less than 6.0 m 50 mm Avoid contact resistances by tightening up all connections. victron energie user manual...
  • Page 20: Connections

    Illustration 7. Input voltage connec- as the output terminal block (see illustration tions. The inverter will be damaged if another alternating current (e.g. from a generator) is connected to the 230 V output. victron energie user manual...
  • Page 21: Battery

    4 milliohms. As previously explained (in section 2.6) the inverter is not protected against reversed polarity. The following procedure should therefore be used: victron energie step 1 Unscrew the four screws on the front of the cabinet (1). step 2 Carefully slide the front of the cabinet to one side.
  • Page 22: Starter Battery

    Atlas Combi may be damaged. Jumpers, general Jumpers are small removable connectors situated on the PCB. By placing and removing the jumpers various features can be enabled or disabled. Illustration 10 shows how to set the jumpers. Illustration 10. Jumpers. victron energie user manual...
  • Page 23: Potentiometers, General

    The screw must be turned by means of a screwdriver (No. 0) and sealed with Tipp-Ex or nail polish (see illustration 11). Illustration 9. Starter battery con- nections. Illustration 11. Potentiometers victron energie user manual...
  • Page 24 manual...
  • Page 25: Start-Up

    = load switched at input float = charging voltage for checking the battery equalize/boost = charging voltage, once battery are fully charged failure = charger not functioning properly Illustration 12. Atlas Combi 12/800 frontpanel. victron energie user manual...
  • Page 26: On" Position

    2. The inverter starts immediately. The “load on inverter” and “on” LEDs light up. 3. The external equipment is reconnected to a 230 V supply within 1 second. 4. The “load on mains” LED goes out and the battery charger is switched off. victron energie user manual...
  • Page 27: Charger

    The “equalize/boost” LED is now off. The battery charger works with the VDL 2-step charging system made by Victron Energie. It automatically keeps the battery in a perfectly charged condition for extended periods. External equipment has immediate access to power.
  • Page 28: Adjustments

    Seal the adjusting screw of potentiometer P6 with nail polish or Tipp-Ex. 5.7.2 Adjustment of voltage The battery charger operates with two charging voltages which must be adjusted separately. First set the low charging voltage (float) and then the high charging voltage (equalize). victron energie user manual...
  • Page 29: Float

    Connect a voltmeter with a reading accuracy of at least 0.1 V to the output of the charger. Turn potentiometer R4 until the correct voltage is set. Seal the adjusting screw of potentiometer R4 with nail polish or Tipp-Ex. Illustration 13. Location of potentiometers on print. victron energie user manual...
  • Page 30: Equalize

    R3 with nail polish or Tipp-Ex. Maintenance The Atlas Combi does not require any special maintenance. It is advisable to check the electrical connections periodically (once a year). Keep the converter as dry and clean as possible. victron energie user manual...
  • Page 31: Fault Tracing List

    The green “on” LED does not light up; go to step 8. step 3 Remove the load from the AC output and check whether the “overload” LED goes out when the inverter is switched on. If it does not, go to step 8. victron energie user manual...
  • Page 32: The Ac Output Voltage Is Too Low

    Check whether the plus (“+”) and minus (“-”) of the battery(ies) and the Atlas Combi correspond. Go to step 8. step 8 Contact your Victron Energie dealer to have the Atlas Combi repaired. The AC output voltage is too low...
  • Page 33: The Battery Charger Does Not Start

    Atlas Combi. The problem has been solved if the fuse operates normally. If it becomes defective again, go to step 4. step 4 Contact your Victron Energie dealer to have the Atlas Combi repaired. The batteries overcharge step 1 Check the battery voltage when the “equalize”...
  • Page 34: The Batteries Do Not Charge Fully

    Contact your Victron dealer to have the Atlas Combi repaired. step 7 Check the mains supply or generator supply for the correct voltage, drops of voltage in lines, excessively long cables, etc. If necessary consult the manufacturer of the item(s) concerned. victron energie user manual...
  • Page 35: Specifications

    2 - 48 Watt Switch-off: 4.5 Watt Test voltage on “auto”: 65 Vrms 50 Hz Efficiency: 91% (maximum) Dynamic stability: Maximum surges of 10% when switching on and off at 50% nominal load. Recovery time is 1/2 period. victron energie user manual...
  • Page 36: Battery Charger

    7.2.2 Output Nominal charging voltage: 12 V Boost charging voltage: 14.25 V Float charging voltage: 13.5 V Charging characteristic: IUoUo according to DIN 41772 Voltage stability: Output current: 30 amp Trickle charge fuse 15 Amp (car fuse) victron energie user manual...
  • Page 37: Changeover

    350 x 250 x 213 mm Weight: 16,5 kg Connecting points: Output 230 V terminals (2.5 mm Output/input 12 V M8 screws Trickle charger: Input: 230 V terminals (2.5 mm Earth M4 screw Cooling: Natural cooling Relative humidity: 95% (maximum) victron energie user manual...
  • Page 38 manual...
  • Page 39: Drawings

    DRAWINGS Complete Victron Energy System Atlas Combi 12/800 cabinet dimensions Remote control connections Atlas Combi 12/800 connections Position jumpers Atlas Combi 12/800 victron energie user manual...
  • Page 40 Victron Atlas Combi service batteries 220 V generator VICTRON MAINS MANAGER victron energie 12 V dc on-board Victron systeem Mains Manager washing machine lighting micro wave victron energie user manual...
  • Page 41 6.5 mm 8.0 mm Victron Atlas Combi 12/800 dimensions © victron energie b.v. victron energie user manual...
  • Page 42 manual...
  • Page 43 manual...
  • Page 44 manual...

Table of Contents