When disinfection is required before final discharge, appropriate disinfection options are available. If used in Std. 350 operation the Clearstream Model CS120UV unit must be installed on discharge.
Page 3
9. Replace UV bulb (when UV is installed) annually * Any sludge removed from pretreatment tank or Clearstream Unit must be disposed of according to all state, local and federal regulatory requirements. To remove solids from pretreatment tank drop pump hose through access opening on top of tank all the way through to the bottom of the tank.
Page 4
Field abuse and overloading of the system can only be cured by the user of the system. 5. When wastewater discharge, into a Clearstream Unit, is seasonal or intermittent to a point that the owner wishes to turn off the electricity (for more than three (3) months) to the aerator, no special service is required.
Page 5
4. All control panels are packaged to prevent damage during shipping and handling. 5. Clearstream electrical control panels are fragile and should be handled as such during shipping and handling. All electrical control panels have circuit breakers, lights and electrical connections and many have relays and timers that are all fragile.
Page 6
Clearstream for more details as to pump size, maximum dosages and maximum flow rates. 2. Set the Clearstream tank in a prepared excavation that has a solid, level bottom that will eliminate tank settling. The excavation bottom should have no rocks or sharp objects present.
Page 7
10. For below normal grade installations a Clearstream 20-inch diameter riser may be used. In no case shall more than 18” of maximum riser depth be used on a Clearstream Unit to bring the access covers above the final grade.
SPECIFICATIONS Model 600DAT Treatment Capacity 600 G.P.D. BOD Loading 1.5 lbs. BOD Aerator CS-103ET6 2.8 scfm Control Panel (Model CS-114) Raintight Electrical 115v/60Hz, 0.75 amps Pretreatment Tank: ½ Plant Design Flow Minimum Capacity 100% of ATU Design Flow Maximum Capacity...
Page 9
DESIGN DRAWING CLEARSTREAM 600DAT " S/40 FLEX AIRLIFT SUPPLY LINE " FLEX AIR LINE SUPPLY 20" ACCESS COVER " S/40 PVC RECYCLE RETURN FLOW LINE 12" ACCESS COVER PRETREAT 4" OUTLET 500GL TANK 4" INLET CS120UV 88" CLEARSTREAM CONTROL PANEL...
Page 10
PARTS LIST AND FLOW DIAGRAM: MODEL 600DAT PART NUMBER: PART NAME: RETURN FLOW LINE TO PRETREAT CS-101 HIGH WATER ALARM FLOAT CS-102 AERATOR CS-103ET6 NAMEPLATE CS-107 ACCESS COVER CS-108 TAMPER RESISTANT SCREW CS-109 ATU TANK CS-11 DIFFUSER CS-113 ALARM PANEL CS-114 PLASTIC 12' DIA.
Page 11
This warranty is a LIMITED WARRANTY and no claim of any nature shall be made against Clearstream unless and until the original retail consumer, or his legal representative, notifies Clearstream in writing of the defect complained of and delivers the product and/or defective part(s), freight prepaid, to Clearstream or an authorized service station.
Page 12
CLEARSTREAM WASTEWATER SYSTEMS, INC. P . O. Box 7568 Beaumont, Texas 77726-7568 Phone: (409) 755-1500 Fax: (409) 755-6500 www.clearstreamsystems.com Revised: 10/1/2020 Copyright:7/01/2013 12 of 12...