Specifications Safetech Eco Inflatable Dock Shelter Model: ECO-500 Overall Width: (mm) 3600 Canopy Width: (mm) 3400 Protrusion of Frame from Building: (mm) Minimum Height from Roadway to Top of Frame: 4910 (mm) Clear Door Opening Width Inflated: (mm) 2300 Clear Door Opening Width Deflated: (mm)
Safetech does not guarantee, warrant, represent or undertake that the information is correct, accurate or current. Safetech is not liable for any loss, claim, cost or expense of any kind arising in any way whatsoever from the information contained in this manual.
Uniquely developed fabric allows the seal to actually breath and inflate to a certain pressure to eliminate over expansion which could cause damage. Eco Dock Shelter| Owner’s Manual| Version no: 1 safetech.com.au...
Maintenance and service on this dock shelter must only be carried out by a person who has been trained & accredited by Safetech. Please contact Safetech for service work or training.
Upon completion of loading/unloading of the truck, turn selector switch to OFF position to deflate the dock shelter. Wait approximately 20 to 30 seconds for dock shelter to fully deflate. Truck is now safe to drive away. Eco Dock Shelter| Owner’s Manual| Version no: 1 safetech.com.au...
Maintenance & Repair Personnel: Safetech Equipment should be serviced and maintained by a qualified a Safetech representative. If you require servicing you can entering into a service agreement with Safetech. Please click on the link to obtain the Safetech Service Agreement.
Safetech. • Train & authorise installers on the safe & correct installation of the unit using personnel and damage to a Safetech Service maintenance prop or equivalent. No if not equipment. • Only suitably trained & skilled personnel to install unit.
Page 12
Untrained people disposing of the Possible Catastrophic Owner • Owner to ensure only Safetech trained and accredited people dispose of the unit. Dock shelter could result in damage to equipment, injury to personnel and non-compliance to regulations. Develop & implement a plan for disposal of the unit.
Page 13
Inadequate service & maintenance Possible Catastrophic Contact Safetech for the regular servicing of your Dock shelter. (3 monthly Owner • service intervals for a heavy workload unit & 6-month service intervals for a of the unit results in unsafe low workload unit.) operation and potential injury to personnel.
Page 14
Do not spray high pressure water on electrical boxes or control panel. faults and potential electrical shock • Include this hazard in your risk assessment. to personnel. Owner • Include this hazard in your risk assessment. Eco Dock Shelter| Owner’s Manual| Version no: 1 safetech.com.au...
Likely Probably occur in 1440 many circumstances Possible Might occur at some time Unlikely Could occur at some time Rare May occur in exceptional circumstances Risk Score Rating: Eco Dock Shelter| Owner’s Manual| Version no: 1 safetech.com.au...
More than 320 Very High Immediate 160-320 High Prompt 70-160 Significant Correction required 40-70 Moderate Attention is needed Less than 40 Perhaps acceptable Drawings Attachment 1 As Built General Arrangement Drawings Eco Dock Shelter| Owner’s Manual| Version no: 1 safetech.com.au...
Need help?