ACCUR8 CO2-6000 User Manual

ACCUR8 CO2-6000 User Manual

Co2 monitor with temperature & humidity

Advertisement

Quick Links

1.
Introduction
Thank you for purchasing this ACCUR8 product. This user manual is to be considered a component of the
device. Read carefully before using the device. Keep in a safe place for future reference. When the device is
sold or given to someone else, the user manual must be provided to the new owner/user of the product.
As part of our ongoing policy to improve the design and specification of our products, we reserve the right to
change any detail given without prior notice. Tempcon Instrumentation Ltd shall not be responsible for any
liability of any nature which may result from the use of any information provided in technical literature.
Errors and technical changes excepted.
© 2022 Tempcon Instrumentation Ltd. All rights reserved.
2.
General Safety Instructions
Risk of electric shock
Only use the device as described in the manual; otherwise, you run the risk of an electric shock.
• Children must only use the device under adult supervision.
• Disconnect the device from the power supply before starting any cleaning of the device.
• Position your device so that it can be disconnected from the power supply at any time. The power socket
should be installed near the device and should be easily accessible as the mains cable plug is used to
disconnect the device from the power supply.
• To disconnect the device from the power supply, always pull on the plug. Never pull on the cable.
• Before starting up the device, check the device, the cables and the connections for signs of damage.
• Never use a damaged device or a device with damaged parts.
• Only use the display console in a dry environment and do not touch it with wet or moist parts of your body.
Risk of suffocation/choking
Improper use of this product can result in suffocation, especially for children. The following safety information
must be observed at all times.
• Keep packaging materials away from children. They can cause suffocation.
• This product contains small parts that could be swallowed by children. There is a risk of choking.
Risk of fire/explosion
Improper use of this product can cause an explosion. The following safety information must be observed at all
times to prevent an explosion.
• Do not expose the device to high temperatures. Excessive heat or improper handling could trigger a short
circuit, a fire, or an explosion.
Risk of damage to property
Improper handling can result in damage to the device and/or to the accessories. Always observe the following
safety information when using the device:
User Manual
ACCUR8 CO2-6000
CO2 Monitor with Temperature & Humidity
1

Advertisement

Table of Contents
loading

Summary of Contents for ACCUR8 CO2-6000

  • Page 1 CO2 Monitor with Temperature & Humidity Introduction Thank you for purchasing this ACCUR8 product. This user manual is to be considered a component of the device. Read carefully before using the device. Keep in a safe place for future reference. When the device is sold or given to someone else, the user manual must be provided to the new owner/user of the product.
  • Page 2: Packing List

    • Never disassemble the device. In the event of a fault, please contact your retailer. • Do not expose this device to high temperatures and protect it from water and high humidity. • Protect the device from severe shocks or excessive vibrations. •...
  • Page 3 Overview LCD Display...
  • Page 4: Restore Factory Defaults

    Restore Factory Defaults In Detection Panel (See image 1), hold the ENTER button for four seconds until an audible beep is heard. (Image 1: Detection Panel) (Image 2: Operation Panel) Menu Bar Press the MENU button once to activate the menu bar, press arrow buttons to cycle and switch function options (press MENU to switch each option in turn until exit).
  • Page 5: Alarm Buzzer

    Alarm Buzzer When it displays , an audible alarm will sound if the CO2 level exceeds a preset CO2 alarm value. means MUTE. Plant Mode and Human Mode When flashes, press ENTER to choose and enter that mode, and it will skip to the next icon. ADV-Alarm Value Use this function to set high and low alarm values for Human Mode and Plant Mode Default alarm values are 800ppm and 1200ppm for both modes.
  • Page 6: Temperature Unit

    Temperature Unit Use this function to choose between Celsius (℃) and Fahrenheit (℉) for the temperature unit display. Time and Date Calibration Before calibration, run this device for at least 20 minutes with window open or in an outdoor environment with backup battery to reach an atmosphere with 400ppm CO2.
  • Page 7: Specifications

    Specifications Typical test conditions: Ambient Temp: 23 ± 3°C, Humidity = 50%-70%, Altitude = 0-100 metres Operating Temperature 32°F - 122°F (0°C - 50°C) Storage Temperature 14°F - 140°F (-10°C - 60°C) Operating & storage Humidity 0-95% (non-condensing) CO2 Measurement Measuring range (0-5000)ppm Display resolution...
  • Page 8: Ec Declaration Of Conformity

    Email: info@accur8tech.com Phone: +44 (0)1243 558 280 ACCUR8 is a registered trademark of Tempcon Instrumentation Ltd EC Declaration of Conformity Tempcon Instrumentation Ltd has issued a declaration of conformity in accordance with applicable guidelines and corresponding standards. The full text of the EC declaration of conformity is available on request from the address above.
  • Page 9 This page has been intentionally left blank.
  • Page 10 This page has been intentionally left blank.
  • Page 11 This page has been intentionally left blank.
  • Page 12 This page has been intentionally left blank.

Table of Contents