Download Print this page
Ebsray RV18 Installation, Operation And Maintenance Instructions

Ebsray RV18 Installation, Operation And Maintenance Instructions

Blackmer bypass valves

Advertisement

Quick Links

BLACKMER BYPASS VALVES
INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS
RV18CBS2, RV18CBS3, RV18VRS10, RV18VRS14, RV18VRS19

TABLE OF CONTENTS

GENERAL
Description ............................................................ 2
Nameplate codes .................................................. 2
Piping .................................................................... 3
Bypass Valve Adjustment ...................................... 4
Operational Checks ............................................... 4
Periodic Inspection ................................................... 4
Preparation for Disassembly .................................... 5
Disassembly ............................................................. 5
Inspection ................................................................. 5
Reassembly ............................................................. 5
PARTS DESIGNATION ................................................... 6
Numbers in parentheses following individual parts indicate
reference numbers on Parts Designation page.
Blackmer instruction manuals and parts lists may be obtained
from
Blackmer's
website
contacting Blackmer Customer Service.
EBSRAY MODEL: RV18
(www.blackmer.com)
When you see this symbol on the product, or in the manual,
look for one of the following signal words and be alert to the
potential for personal injury, death or major property
Warns of hazards that WILL cause serious personal injury,
Warns of hazards that CAN cause serious personal injury,
Warns of hazards that CAN cause personal injury
Indicates special instructions which are very
Blackmer external bypass valves MUST only be
installed in systems which have been designed by
qualified engineering personnel. The system MUST
conform
Page
regulations and safety standards.
This manual is intended to assist in the installation
and operation of Blackmer bypass valves, and MUST
be kept with the bypass valve.
Blackmer bypass valve service shall be performed by
qualified technicians ONLY. Service shall conform to
all applicable local and national regulations and
safety standards.
Thoroughly review this manual, all Instructions and
hazard warnings, BEFORE performing any work on
the Blackmer bypass valves.
Maintain ALL system and Blackmer liquefied gas
pump operation and hazard warning decals.
or
by
967020
INSTRUCTIONS NO. 551-E00
Section
Effective
Replaces
SAFETY DATA
This is a SAFETY ALERT SYMBOL.
damage
death or major property damage.
death or major property damage.
or property damage.
NOTICE:
important and must be followed.
NOTICE:
to
all
applicable
local
551
Aug 2015
Nov 2014
and
national

Advertisement

loading

Summary of Contents for Ebsray RV18

  • Page 1: Table Of Contents

    BLACKMER BYPASS VALVES INSTRUCTIONS NO. 551-E00 INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS Section Effective Aug 2015 EBSRAY MODEL: RV18 Replaces Nov 2014 RV18CBS2, RV18CBS3, RV18VRS10, RV18VRS14, RV18VRS19 SAFETY DATA This is a SAFETY ALERT SYMBOL. When you see this symbol on the product, or in the manual,...
  • Page 2: Description

    DESCRIPTION The Ebsray RV Model No. Code on the Nameplate identifies the valve type and spring fitted to the Bypass valve. The EBSRAY Models RV18 Bypass Valves are intended to...
  • Page 3: Installation

    INSTALLATION NOTICE: INSTALLATION At temperatures below -20° F (-28.9° C) materials have On liquefied gas systems, an external bypass valve, piped reduced impact strength. Provisions should be made to back to the supply tank, is necessary for maximum pump prevent tools and other objects from impacting any performance and longer pump life.
  • Page 4: Bypass Valve Adjustment

    Hazardous LUBRICATION machinery can cause serious personal No ‘in service’ lubrication is required on Ebsray Model RV18 injury. Bypass Valves. PERIODIC INSPECTION Disconnecting fluid or pressure Periodic Inspection of the Bypass Valve, Pump System and...
  • Page 5: Preparation For Disassembly

    MAINTENANCE PREPARATION FOR DISASSEMBLY REASSEMBLY 1. Isolate Bypass Valve from liquids/vapor in inlet and Refer to the Parts Designation drawings. discharge lines, depressurize and purge any toxic, 4. VRS OPTION ONLY: Insert Spring - Vent (13) into Valve flammable, corrosive or air hardening liquid/vapor. (3a) with large end seating in Valve, insert Ball (12) after 2.
  • Page 6: Parts Designation

    PARTS DESIGNATION MODELS: RV18 Inline Bypass Valves. Ref. Description Ref. Description Housing NPT 0-Ring, 1/8x2 Valve Cover Adjusting Screw Valve Socket Hd Capscrew M8x1.25x25 Valve Nut Hexagon Head Metric Spring Cap Ball Spring Bypass Spring Vent 0-Ring, 1/8x1-7/16 Circlip Spare Parts Inquiries To facilitate Parts inquiries, please provide Blackmer with: a.

This manual is also suitable for:

Rv18cbs2Rv18cbs3Rv18vrs10Rv18vrs14Rv18vrs19