Instrunction Sheet
(1) Preface
Thank you for purchasing DELTA's HMC Series. This instruction sheet will be helpful in the installation, wiring and
inspection of Delta HMI product. Before using the product, please read this instruction sheet to ensure correct use. You
should thoroughly understand all safety precautions before proceeding with the installation, wiring and operation. Place
this instruction sheet in a safe location for future reference. Please observe the following precautions:
Install the product in a clean and dry location free from corrosive and inflammable gases or liquids.
Ensure that all wiring instructions and recommendations are followed.
Ensure that HMI is correctly connected to a ground. The grounding method must comply with the electrical
standard of the country (Please refer to NFPA 70: National Electrical Code, 2005 Ed.).
Do not disassemble HMI, modify or remove wiring when power is applied to HMI.
Do not touch the power supply during operation. Otherwise, it may cause electric shock.
If you have any questions during operation, please contact our local distributors or Delta sales representatives.
The content of this instruction sheet may be revised without prior notice. Please consult our distributors or download the
most updated version at
http://www.delta.com.tw/ia
(2) Safety Precautions
Carefully note and observe the following safety precautions when receiving, inspecting, installing, operating, maintaining
and troubleshooting. The following words, DANGER, WARNING and STOP are used to mark safety precautions when
using the Delta's HMI product. Failure to observe these precautions may void the warranty!
Installation
 Comply with quick start for installation. Otherwise it may cause equipment damage.
 Do not install the product in a location that is outside the stated specification for the HMI. Failure to
observe this caution may result in electric shock, fire, or explosion.
 Do not install the product in a location where temperatures will exceed specification for the HMI.
Failure to observe this caution may result in abnormal operation or damage the product.
 Please note that this equipment has obtained EMC registration for commercial use. In the event that it
has been mistakenly sold or purchased, please exchange it for equipment certified for home use.
 Do not use this product as an alarm device for disaster early warning that may result in personal injury,
equipment damage, or system emergency stop.
Wiring
 Connect the ground terminals to a class-3 ground (Ground resistance should not exceed 100Ω).
Improper grounding may result in communication error, electric shock or fire.
Operation
 The users should use Delta program editor software, DOPSoft to perform editing in Delta's HMI
product. To perform editing and confirming HMI programs without using Delta program editor software,
DOPSoft in Delta's HMI product may result in abnormal operation.
 To prevent the personal injury and equipment damage, when designing HMI programs, please ensure
that a communication error occurred between Delta's HMI product and the connecting controller or
equipment will not result in system failure or malfunction.
 Please be sure to backup the screen data and HMI programs in case they are lost, accidentally
deleted or worse.
 Do not modify wiring during operation. Otherwise it may result in electric shock or personal injury.
 Never use a hard or pointed object to hit or strike the screen as doing this may damage the screen and
let the screen has not respond at all, and then cause HMI to work abnormally.
Maintenance and Inspection
 Do not touch any internal or exposed parts of the HMI as electrical shock may result.
 Do not remove operation panel while power is on. Otherwise electrical shock may result.
 Wait at least 10 minutes after power has been removed before touching any HMI terminals or
performing any wiring and/or inspection as an electrical charge may still remain in the HMI with
hazardous voltages even after power has been removed.
 Turn the power off before changing backup battery and check system settings after finishing change.
(all data will be cleared after changing battery).
 Be sure the ventilation holes are not obstructed during operation. Otherwise malfunction may result
due to bad ventilation or overheating troubles.
Wiring Method
 Do not use a voltage that will exceed specification for the HMI. Failure to observe this caution may
result in electric shock or fire.
 Remove the terminal block from the HMI before wiring.
 Insert only one wire into one terminal on the terminal block.
 If the wiring is in error, perform the wiring again with proper tools. Never use force to remove the
terminals or wires. Otherwise, it may result in malfunction or damage.
 For the power line that forced to take out, ensure to check wiring again and restart.
Communication Wiring
 Comply with communication wiring specification for wiring.
 Wiring length should comply with the stated specification for the HMI.
 Proper grounding to avoid bad communication quality.
 To avoid noise and interference, the communication cable, all power cables, and motor power cable
should be placed in separate conduits.
(3) Model Explanation
HMC
07
-
N
5
00
(1)
(2)
(3)
(4)
(5)
(1)
Product Name
(2)
LCM Size
(3)
Type of Industries
(4)
Display Resolution
(5)
Version
(6)
Type of Model
(7)
External Control Interface (Bus)
(8)
Controller Remote Unit Interface
(4) Parts Names
HMC07-N500H52 / HMC07-N510H52 / HMC07-N511H52 (Front View)
A
A
Power LED Indicator
C
Touch Screen / Display
HMC07-N500H52 / HMC07-N510H52 / HMC07-N511H52 (Rear View)
A
3-Position Operation Switch
HMC07-N500H52 / HMC07-N510H52 / HMC07-N511H52 (Top View)
(5) Installation and Storage Conditions
The product should be kept in the shipping carton before installation. In order to retain the warranty coverage, the HMI
should be stored properly when it is not to be used for an extended period of time. Some storage suggestions are:
Store in a clean and dry location free from direct sunlight.
H
5
2
Store within an ambient temperature range of -20°C to +60°C (-4°F to 140°F).
Store within a relative humidity range of 10% to 90% and non-condensing.
(6)
(7)
(8)
Do not store the HMI in a place subjected to corrosive gases and liquids.
HMC: HMI with Controller
07: 7-inch TFT LCD
N: General Purpose
5: SVGA
00、10、11
H: Handy (Hand-held) Type
5: DMCNET
2: Specialized High-speed RS-422
B
Auxiliary Function Keys (F1~F10)
D
Emergency Stop Switch
B
B
Cable Interface (Power Plug Connector)
A
B
C
A
USB Slave
B
USB Host
C
SD Card
Correctly packaged and placed on a solid and durable surface.
Do not mount the HMI adjacent to heat-radiating elements or in direct sunlight.
Do not mount the HMI in a location subjected to corrosive gases, liquids, or airborne dust or metallic particles.
Do not mount the HMI in a location where temperatures and humidity will exceed specification.
Do not mount the HMI in a location where vibration and shock will exceed specification.
Do not mount the HMI in a location where it will be subjected to high levels of electromagnetic radiation.
(6) Wiring Method
Be sure to perform wiring by referring to the following figures.
Before Wiring
Ensure to plug the power cable into the connector
(power supply connector) by following the
shown as below.
D
Note
Correctly connect RJ-45 connector to remote module
or ASDA servo drive.
B
C
(7) Wring Types
A
After Wiring
After the wiring is completed, the connection will be
shown as the figure below.
direction
Note
The height shall be 60 mm at least. Do not excessively
bend the cable.
X

Advertisement

loading

Summary of Contents for Delta HMS Series

  • Page 1 HMC07-N500H52 / HMC07-N510H52 / HMC07-N511H52 (Front View) inspection of Delta HMI product. Before using the product, please read this instruction sheet to ensure correct use. You should thoroughly understand all safety precautions before proceeding with the installation, wiring and operation. Place this instruction sheet in a safe location for future reference.
  • Page 2 White / Purple 422_RX- RS422: R- Display Size 141 x 105.75mm Users can download the DOPSoft, the program editor of Delta HMI product and the user manual via the following link: http://www.delta.com.tw/ia. Operation System Delta Real Time OS Black / Orange...
  • Page 3 (1) Önsöz (4) Parça Adları DELTA’nın HMC serisi operatör panellerini seçtiğiniz için teşekkürler. Bu bilgi dokümanı Delta HMI kurulum, bağlantı, bakım ve kontrolünde kullanıcıya yardımcı olacaktır. Doğru kullanım için ürünü kullanmadan önce bu dokümanı mutlaka HMC07-N500H52 / HMC07-N510H52 / HMC07-N511H52 (Ön Görünüm) okuyunuz.
  • Page 4 HMI’nın boş iken tükettiği gücün 1,5 veya 2 katı güç verebilen besleme kaynağı kullanılması tavsiye edilir. Aydınlatma 422_RX+ RS422: R+, RS232:RX Delta HMI ürünleri program editörü DOPSoft ve kullanım kılavuzlarını aşağıdaki linkten yükleyebilirsiniz: Display Ölçüsü 141 x 105.75mm http://www.delta.com.tw/ia. Beyaz / Mor...
  • Page 5 接線時,請依接線圖說明施工。  接地工程必須確實實施,接地時須遵照國家現行相關電工法規之規定施行(請參考 NFPA 70: National Electrical  Code, 2005 Ed.) 。 在通電時,請勿拆解人機介面或更改配線。  在通電運作時,請勿接觸電源處,以免觸電。  如果您在使用上仍有問題,請洽詢經銷商或者本公司客服中心。由於產品精益求精,當內容規格有所修正時,請洽詢代理 商或至台達網站(http://www.delta.com.tw/ia)下載最新版本。 (2) 安全注意事項 安裝、配線、操作、維護及檢查時,應隨時注意以下安全注意事項。 注意事項 注意事項 安裝注意 依據 RJ-45 接頭正確方向,接上 Remote 模組 接線高度至少 60 mm,不要過度折彎  依照手冊指定的方式安裝人機介面,否則可能導致設備損壞。 或 ASDA Servo Driver  禁止將本產品暴露在有水氣、腐蝕性氣體、可燃性氣體等物質的場所下使用,否則可能會造成觸電、火...
  • Page 6 RJ45 綠 RemoteIO 接線 5) 消耗功率為無外接週邊設備時,人機本體所消耗的功率。建議選用的電源供應器容量為標示消耗功率之 1.5~2 倍,以 SDRAM 64Mbytes 確保人機工作正常。 斷電保持內部 12 pin Type A:HMC-CA1203A0(3M)、HMC-CA1205A0 (5M)、HMC-CA1210A0 (10M) 16Mbytes 6) HMC 系列編輯軟體 DOPSoft 系列及其使用操作手冊,可由台達網站下載取得,網址為 http://www.delta.com.tw/ia。 記憶體 (Bytes) 7) 本人機介面安裝手冊內所記載之規格若有變更,本公司恕不另行通知。當內容規格有所修正時,請洽詢代理商或至台 線條名稱 編號名稱 說明 音 蜂鳴器 Multi-Tone Frequency(2K ~ 4K Hz)/85dB 達網站...
  • Page 7 Code, 2005 Ed.) 。 或 ASDA Servo Driver 在通电时,请勿拆解人机接口或更改配线。  在通电运作时,请勿接触电源处,以免触电。  电源指示灯 辅助键(F1~F10) 如果您在使用上仍有问题,请咨询经销商或者本公司客服中心。由于产品精益求精,当内容规格有所修正时,请咨询代理 操作/显示区域 紧急停止按钮 商或至台达网站(http://www.delta.com.tw/ia)下载最新版本。 (2) 安全注意事项 HMC07-N500H52 / HMC07-N510H52 / HMC07-N511H52(背面) 安装、配线、操作、维护及检查时,应随时注意以下安全注意事项。 安装注意  依照手册指定的方式安装人机接口,否则可能导致设备损坏。  禁止将本产品暴露在有水气、腐蚀性气体、可燃性气体等物质的场所下使用,否则可能会造成触电、火 灾或爆炸。 (7) 配线种类  请勿将人机接口安装在超过规格范围的温度环境中,否则可能造成人机接口无法正常运作或损坏。  本产品为 KCC Class A(商用设备)产品且通过试验认证,其设计的目的是在商业或是工业环境使用,...
  • Page 8 64Mbytes RJ45 绿 RemoteIO 接线 5) 消耗功率为无外接外围设备时,人机本体所消耗的功率。建议选用的电源供应器容量为标示消耗功率之 1.5~2 倍,以 断电保持内部 16Mbytes 确保人机工作正常。 内存 (Bytes) 12 pin Type A:HMC-CA1203A0(3M)、HMC-CA1205A0 (5M)、HMC-CA1210A0 (10M) 6) HMC 系列编辑软件 DOPSoft 系列及其使用操作手册,可由台达网站下载取得,网址为 http://www.delta.com.tw/ia。 音 蜂鸣器 Multi-Tone Frequency(2K ~ 4K Hz)/85dB 7) 本人机接口安装手册内所记载的规格若有变更,本公司恕不另行通知。当内容规格有所修正时,请咨询代理商或至台 线条名称 编号名称 说明 效 输...

This manual is also suitable for:

Hmc07 seriesHmc07-n500h52Hmc07-n510h52Hmc07-n511h52