High Color‧Motion Inside‧
07
HMC
User-Friendly HMI Products
No.18, Xinglong Rd., Taoyuan City
33068, Taiwan
Instrunction Sheet
(1) Preface
Thank you for purchasing DELTA's HMC Series. This instruction sheet will be helpful in the installation, wiring and
inspection of Delta HMI product. Before using the product, please read this instruction sheet to ensure correct use. You
should thoroughly understand all safety precautions before proceeding with the installation, wiring and operation. Place
this instruction sheet in a safe location for future reference. Please observe the following precautions:
Install the product in a clean and dry location free from corrosive and inflammable gases or liquids.
Ensure that all wiring instructions and recommendations are followed.
Ensure that HMI is correctly connected to a ground. The grounding method must comply with the electrical
standard of the country (Please refer to NFPA 70: National Electrical Code, 2005 Ed.).
Do not disassemble HMI, modify or remove wiring when power is applied to HMI.
Do not touch the power supply during operation. Otherwise, it may cause electric shock.
If you have any questions during operation, please contact our local distributors or Delta sales representatives.
The content of this instruction sheet may be revised without prior notice. Please consult our distributors or download the
most updated version at
http://www.delta.com.tw/ia
(2) Safety Precautions
Carefully note and observe the following safety precautions when receiving, inspecting, installing, operating, maintaining
and troubleshooting. The following words, DANGER, WARNING and STOP are used to mark safety precautions when
using the Delta's HMI product. Failure to observe these precautions may void the warranty!
Installation
Comply with quick start for installation. Otherwise it may cause equipment damage.
Do not install the product in a location that is outside the stated specification for the HMI. Failure to
observe this caution may result in electric shock, fire, or explosion.
Do not install the product in a location where temperatures will exceed specification for the HMI.
Failure to observe this caution may result in abnormal operation or damage the product.
Please note that this equipment has obtained EMC registration for commercial use. In the event that it
has been mistakenly sold or purchased, please exchange it for equipment certified for home use.
Do not use this product as an alarm device for disaster early warning that may result in personal injury,
equipment damage, or system emergency stop.
Wiring
Connect the ground terminals to a class-3 ground (Ground resistance should not exceed 100Ω).
Improper grounding may result in communication error, electric shock or fire.
Operation
The users should use Delta program editor software, DOPSoft to perform editing in Delta's HMI
product. To perform editing and confirming HMI programs without using Delta program editor software,
DOPSoft in Delta's HMI product may result in abnormal operation.
To prevent the personal injury and equipment damage, when designing HMI programs, please ensure
that a communication error occurred between Delta's HMI product and the connecting controller or
equipment will not result in system failure or malfunction.
Please be sure to backup the screen data and HMI programs in case they are lost, accidentally
deleted or worse.
Do not modify wiring during operation. Otherwise it may result in electric shock or personal injury.
Never use a hard or pointed object to hit or strike the screen as doing this may damage the screen and
let the screen has not respond at all, and then cause HMI to work abnormally.
Maintenance and Inspection
Do not touch any internal or exposed parts of the HMI as electrical shock may result.
Do not remove operation panel while power is on. Otherwise electrical shock may result.
Wait at least 10 minutes after power has been removed before touching any HMI terminals or
performing any wiring and/or inspection as an electrical charge may still remain in the HMI with
hazardous voltages even after power has been removed.
Turn the power off before changing backup battery and check system settings after finishing change.
(all data will be cleared after changing battery).
Be sure the ventilation holes are not obstructed during operation. Otherwise malfunction may result
due to bad ventilation or overheating troubles.
Wiring Method
Do not use a voltage that will exceed specification for the HMI. Failure to observe this caution may
result in electric shock or fire.
Remove the terminal block from the HMI before wiring.
Insert only one wire into one terminal on the terminal block.
If the wiring is in error, perform the wiring again with proper tools. Never use force to remove the
terminals or wires. Otherwise, it may result in malfunction or damage.
For the power line that forced to take out, ensure to check wiring again and restart.
Communication Wiring
Comply with communication wiring specification for wiring.
Wiring length should comply with the stated specification for the HMI.
Proper grounding to avoid bad communication quality.
To avoid noise and interference, the communication cable, all power cables, and motor power cable
should be placed in separate conduits.
(3) Model Explanation
HMC
07
-
N
5
00
(1)
(2)
(3)
(4)
(5)
(1)
Product Name
(2)
LCM Size
(3)
Type of Industries
(4)
Display Resolution
(5)
Version
(6)
Type of Model
(7)
External Control Interface (Bus)
(8)
Controller Remote Unit Interface
(4) Parts Names
HMC07-N500H52 / HMC07-N510H52 / HMC07-N511H52 (Front View)
A
A
Power LED Indicator
C
Touch Screen / Display
HMC07-N500H52 / HMC07-N510H52 / HMC07-N511H52 (Rear View)
A
3-Position Operation Switch
HMC07-N500H52 / HMC07-N510H52 / HMC07-N511H52 (Top View)
(5) Installation and Storage Conditions
The product should be kept in the shipping carton before installation. In order to retain the warranty coverage, the HMI
should be stored properly when it is not to be used for an extended period of time. Some storage suggestions are:
Store in a clean and dry location free from direct sunlight.
H
5
2
Store within an ambient temperature range of -20°C to +60°C (-4°F to 140°F).
Store within a relative humidity range of 10% to 90% and non-condensing.
(6)
(7)
(8)
Do not store the HMI in a place subjected to corrosive gases and liquids.
HMC: HMI with Controller
07: 7-inch TFT LCD
N: General Purpose
5: SVGA
00、10、11
H: Handy (Hand-held) Type
5: DMCNET
2: Specialized High-speed RS-422
B
Auxiliary Function Keys (F1~F10)
D
Emergency Stop Switch
B
B
Cable Interface (Power Plug Connector)
A
B
C
A
USB Slave
B
USB Host
C
SD Card
Correctly packaged and placed on a solid and durable surface.
Do not mount the HMI adjacent to heat-radiating elements or in direct sunlight.
Do not mount the HMI in a location subjected to corrosive gases, liquids, or airborne dust or metallic particles.
Do not mount the HMI in a location where temperatures and humidity will exceed specification.
Do not mount the HMI in a location where vibration and shock will exceed specification.
Do not mount the HMI in a location where it will be subjected to high levels of electromagnetic radiation.
(6) Wiring Method
Be sure to perform wiring by referring to the following figures.
Before Wiring
Ensure to plug the power cable into the connector
(power supply connector) by following the
shown as below.
D
Note
Correctly connect RJ-45 connector to remote module
or ASDA servo drive.
B
C
(7) Wring Types
A
After Wiring
After the wiring is completed, the connection will be
shown as the figure below.
direction
Note
The height shall be 60 mm at least. Do not excessively
bend the cable.
X